Traditionally dehydration has been a triethylene glycol (TEG) unit utilizing a 4-8 tray absorber with bubble cap trays. These units work well and are relatively inexpensive. However, there has been an increasing concern about hydrocarbons emission from the vent gas and produced water over the last few years. The hydrocarbons of greatest concern are benzene, toluene, ethyl benzene, and xylene (BTEX). Units can be added on to mitigate the emissions but they take up extra space and weight which is expensive offshore. Therefore, there is an increased interest in decreasing the cost and size of conventional units or finding an alternative process that is less expensive. Under Gas Research Institute contract a survey of a number of offshore producers to determine present practices was conducted. Several absorber alternatives and/or modifications for conventional TEG units were compared with a hypothetical membrane unit for dehydration of 75 mmscfd of natural gas at 1000 psia and 100°F. Although commercial membrane units are not yet available a "good" hypothetical unit was compared because of its advantages of simplicity and lack of emissions. The membrane unit, however, was not found to be competitive. A TEG unit with a Higee? absorber was found to have a slight advantage over more conventional trayed and random and structured packing absorbers after taking into account the effect of size and weight as well as initial cost.
SURVEY OF OFFSHORE PRODUCERS
A survey of seventeen offshore producers was performed to generate the following information: (Foral, 1994)Present offshore dehydration practices;Level of industry concern over emissions; andA design basis that would be typical of Gulf of Mexico offshore operating conditions.
Eleven companies responded to the survey indicating that the most commonly employed dehydration process used was TEG dehydration with bubble cap trays. In evaluating alternatives, most respondents reported that savings in size and weight were considered important. The savings in size (footprint) was considered somewhat less important than weight. The level of reliability required for offshore processes was reported by most respondents to be in excess of 95%. Before an alternative process would be considered for offshore use, the consensus of the respondents was that:The unit size should be no larger than existing units with equal performance.There should be a history of successful operation for a period of at least 1-3 years.Materials of construction should be compatible with the offshore environment.
Most of the companies indicated that environmental regulations of the emissions of BTEX and other VOC from offshore sources require research and development to develop new technology.
BASIS OF EVALUATION
Operating Conditions.
The operating conditions chosen for sizing the units were:A flow of 75 mmscfd at 1000 psia and 100°F.The gas was assumed to be methane saturated with water.A fuel gas usage equal to 3.4% of the feed at 135 psia.
Title: Offshore Dehydration Of Natural Gas: An Evaluation Of Alternatives
Description:
ABSTRACT
Traditionally dehydration has been a triethylene glycol (TEG) unit utilizing a 4-8 tray absorber with bubble cap trays.
These units work well and are relatively inexpensive.
However, there has been an increasing concern about hydrocarbons emission from the vent gas and produced water over the last few years.
The hydrocarbons of greatest concern are benzene, toluene, ethyl benzene, and xylene (BTEX).
Units can be added on to mitigate the emissions but they take up extra space and weight which is expensive offshore.
Therefore, there is an increased interest in decreasing the cost and size of conventional units or finding an alternative process that is less expensive.
Under Gas Research Institute contract a survey of a number of offshore producers to determine present practices was conducted.
Several absorber alternatives and/or modifications for conventional TEG units were compared with a hypothetical membrane unit for dehydration of 75 mmscfd of natural gas at 1000 psia and 100°F.
Although commercial membrane units are not yet available a "good" hypothetical unit was compared because of its advantages of simplicity and lack of emissions.
The membrane unit, however, was not found to be competitive.
A TEG unit with a Higee? absorber was found to have a slight advantage over more conventional trayed and random and structured packing absorbers after taking into account the effect of size and weight as well as initial cost.
SURVEY OF OFFSHORE PRODUCERS
A survey of seventeen offshore producers was performed to generate the following information: (Foral, 1994)Present offshore dehydration practices;Level of industry concern over emissions; andA design basis that would be typical of Gulf of Mexico offshore operating conditions.
Eleven companies responded to the survey indicating that the most commonly employed dehydration process used was TEG dehydration with bubble cap trays.
In evaluating alternatives, most respondents reported that savings in size and weight were considered important.
The savings in size (footprint) was considered somewhat less important than weight.
The level of reliability required for offshore processes was reported by most respondents to be in excess of 95%.
Before an alternative process would be considered for offshore use, the consensus of the respondents was that:The unit size should be no larger than existing units with equal performance.
There should be a history of successful operation for a period of at least 1-3 years.
Materials of construction should be compatible with the offshore environment.
Most of the companies indicated that environmental regulations of the emissions of BTEX and other VOC from offshore sources require research and development to develop new technology.
BASIS OF EVALUATION
Operating Conditions.
The operating conditions chosen for sizing the units were:A flow of 75 mmscfd at 1000 psia and 100°F.
The gas was assumed to be methane saturated with water.
A fuel gas usage equal to 3.
4% of the feed at 135 psia.
Related Results
Theoretical study of laser-cooled SH<sup>–</sup> anion
Theoretical study of laser-cooled SH<sup>–</sup> anion
The potential energy curves, dipole moments, and transition dipole moments for the <inline-formula><tex-math id="M13">\begin{document}${{\rm{X}}^1}{\Sigma ^ + }$\end{do...
Permeation: A New Competitive Process for Offshore Gas Dehydration
Permeation: A New Competitive Process for Offshore Gas Dehydration
ABSTRACT
Usual process for gas dehydration implement absorption (glycol chemical process) or adsorption (molecular sieves).
The new dehydration ...
Use of Bandra Formation Lean Gas as Fuel Gas at Heera Processing Complex (Offshore)
Use of Bandra Formation Lean Gas as Fuel Gas at Heera Processing Complex (Offshore)
Abstract
HEERA, one of the most promising hydrocarbon producing fields in Mumbai offshore; produces oil and gas from multilayered pay zones ranging from depth of 700...
Acid-base and Electrolyte Disturbances in Children Presenting with Acute Watery Diarrhoea in Emergency Observation and Referral Unit of Dhaka Shishu (Children) Hospital
Acid-base and Electrolyte Disturbances in Children Presenting with Acute Watery Diarrhoea in Emergency Observation and Referral Unit of Dhaka Shishu (Children) Hospital
Background: Acute watery diarrhoea (AWD) is a leading cause of illness and death amongst children in developing countries. Electrolyte and acid-base disturbances play an important ...
Processing Sour Natural Gas To Meet Pipeline Quality
Processing Sour Natural Gas To Meet Pipeline Quality
Abstract
The processing of sour natural gas is gaining interest and popularity due to the search for additional sources of available energy. The decision to build...
Alternative Offshore Foundation Installation Methods
Alternative Offshore Foundation Installation Methods
Abstract
According to the European Wind Energy Association (EWEA) in the first six months of 2012, Europe installed and fully grid connected 132 offshore wind tur...
Capacity Expansion of Gas Dehydration and Processing System via S-Turbo Train Debottlenecking Technology- A G-Field Success Story
Capacity Expansion of Gas Dehydration and Processing System via S-Turbo Train Debottlenecking Technology- A G-Field Success Story
Abstract
The increasing global demand for clean energy sources has led to a surge in natural gas consumption. As the world transitions towards a low-carbon economy, ...
Offshore Giant Fields, 1950-1990
Offshore Giant Fields, 1950-1990
ABSTRACT
OFFSHORE GIANT FIELDS
1950 - 1990
During the past forty years...