Fracture Resistance of CAD/CAM Implant-Supported 3Y-TZP-Zirconia Cantilevers: An In Vitro Study
View through CrossRef
(1) Introduction: Implant-supported fixed complete dentures are mostly composed of cantilevers. The purpose of this work was to evaluate the fracture resistance of zirconia (Prettau®, second generation, or Ice Zirkon Translucent, first generation) with cantilever lengths of 6 and 10 mm, and zirconia’s fracture resistance in relation to an average bite force of 250 N. (2) Materials and methods: Forty structures were created in CAD/CAM and divided into four groups: group A (6 mm cantilever in IZT), group B (10 mm cantilever in IZT), group C (6 mm cantilever in Pz), and group D (10 mm cantilever in pz). The study consisted of a traditional “load-to-failure” test. (3) Results: A statistically significant result was found for the effect of cantilever length, t(38) = 16.23 (p < 0.001), with this having a large effect size, d = 4.68. The 6 mm cantilever length (M = 442.30, sd = 47.49) was associated with a higher mean force at break than the 10 mm length (M = 215.18, sd = 40.74). No significant effect was found for the type of zirconia: t(38) = 0.31 (p = 0.757), and d = 0.10. (4) Conclusions: All the components with cantilever lengths of 6 mm broke under forces higher than 250 N. Cantilevers larger than 10 mm should be avoided.
Title: Fracture Resistance of CAD/CAM Implant-Supported 3Y-TZP-Zirconia Cantilevers: An In Vitro Study
Description:
(1) Introduction: Implant-supported fixed complete dentures are mostly composed of cantilevers.
The purpose of this work was to evaluate the fracture resistance of zirconia (Prettau®, second generation, or Ice Zirkon Translucent, first generation) with cantilever lengths of 6 and 10 mm, and zirconia’s fracture resistance in relation to an average bite force of 250 N.
(2) Materials and methods: Forty structures were created in CAD/CAM and divided into four groups: group A (6 mm cantilever in IZT), group B (10 mm cantilever in IZT), group C (6 mm cantilever in Pz), and group D (10 mm cantilever in pz).
The study consisted of a traditional “load-to-failure” test.
(3) Results: A statistically significant result was found for the effect of cantilever length, t(38) = 16.
23 (p < 0.
001), with this having a large effect size, d = 4.
68.
The 6 mm cantilever length (M = 442.
30, sd = 47.
49) was associated with a higher mean force at break than the 10 mm length (M = 215.
18, sd = 40.
74).
No significant effect was found for the type of zirconia: t(38) = 0.
31 (p = 0.
757), and d = 0.
10.
(4) Conclusions: All the components with cantilever lengths of 6 mm broke under forces higher than 250 N.
Cantilevers larger than 10 mm should be avoided.
Related Results
Influence of sandblasting on zirconia in restorative dentistry
Influence of sandblasting on zirconia in restorative dentistry
La utilización de circona tetragonal policristalina estabilizada con 3 % mol de itria (3Y-TZP)
para fabricar coronas e implantes ha sufrido una fuerte expansión recientemente debi...
Mechanical properties of co-doped zirconia ceramics
Mechanical properties of co-doped zirconia ceramics
Tetragonal polycrystalline zirconia, commonly stabilised with 3 mol% yttria (3Y-TZP), became one of the most interesting ceramics for biomedical applications due to its biocompatib...
Processing and properties of zirconia-CNT composites
Processing and properties of zirconia-CNT composites
In the last decades there has been growing interest in developing ceramic materials with high fracture toughness (Klc) and strength for structural applications. In the specific cas...
Comparative Microscopic and Radiographic Evaluation of Proximal Marginal Integrity of CAD/CAM PMMA Crown and CAD/CAM Zirconia Monolithic Crown- An In-vitro Study
Comparative Microscopic and Radiographic Evaluation of Proximal Marginal Integrity of CAD/CAM PMMA Crown and CAD/CAM Zirconia Monolithic Crown- An In-vitro Study
ABSTRACTS
Aim: to evaluate and compare proximal marginal integrity radiographically and microscopically of CAD/CAM PMMA crown and CAD/CAM monolithic zirconia crown.
Mat...
Comparative Evaluation of Fracture Strength of Implant Supported Crown Fabricated from CAD/CAM and 3D Printed Resin Matrix Ceramic
Comparative Evaluation of Fracture Strength of Implant Supported Crown Fabricated from CAD/CAM and 3D Printed Resin Matrix Ceramic
Objective: To compare fracture strength of screw-retained implant-supported crown of resin matrix ceramic when fabricated using CAD/CAM and 3D printing Material and method: vericom...
Effects of Veneering Ceramic and Methods on Failure Load of Veneered Zirconia
Effects of Veneering Ceramic and Methods on Failure Load of Veneered Zirconia
Background: A variety of veneering options to zirconia frameworks are now available. The purpose of this study is to evaluate the effect of veneer materials, veneering methods, cem...
Surface stability and small-scale testing of zirconia
Surface stability and small-scale testing of zirconia
Tetragonal polycrystalline zirconia stabilized with 3 mol% of yttria (3Y-TZP) is a biocompatible ceramic showing superior mechanical properties, which are partly the consequence of...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference.
Abstract
Fractures are ubiquitous st...