Fracture Resistance of CAD/CAM Implant-Supported 3Y-TZP-Zirconia Cantilevers: An In Vitro Study

View through CrossRef
(1) Introduction: Implant-supported fixed complete dentures are mostly composed of cantilevers. The purpose of this work was to evaluate the fracture resistance of zirconia (Prettau®, second generation, or Ice Zirkon Translucent, first generation) with cantilever lengths of 6 and 10 mm, and zirconia’s fracture resistance in relation to an average bite force of 250 N. (2) Materials and methods: Forty structures were created in CAD/CAM and divided into four groups: group A (6 mm cantilever in IZT), group B (10 mm cantilever in IZT), group C (6 mm cantilever in Pz), and group D (10 mm cantilever in pz). The study consisted of a traditional “load-to-failure” test. (3) Results: A statistically significant result was found for the effect of cantilever length, t(38) = 16.23 (p < 0.001), with this having a large effect size, d = 4.68. The 6 mm cantilever length (M = 442.30, sd = 47.49) was associated with a higher mean force at break than the 10 mm length (M = 215.18, sd = 40.74). No significant effect was found for the type of zirconia: t(38) = 0.31 (p = 0.757), and d = 0.10. (4) Conclusions: All the components with cantilever lengths of 6 mm broke under forces higher than 250 N. Cantilevers larger than 10 mm should be avoided.
Title: Fracture Resistance of CAD/CAM Implant-Supported 3Y-TZP-Zirconia Cantilevers: An In Vitro Study
Description:
(1) Introduction: Implant-supported fixed complete dentures are mostly composed of cantilevers.
The purpose of this work was to evaluate the fracture resistance of zirconia (Prettau®, second generation, or Ice Zirkon Translucent, first generation) with cantilever lengths of 6 and 10 mm, and zirconia’s fracture resistance in relation to an average bite force of 250 N.
(2) Materials and methods: Forty structures were created in CAD/CAM and divided into four groups: group A (6 mm cantilever in IZT), group B (10 mm cantilever in IZT), group C (6 mm cantilever in Pz), and group D (10 mm cantilever in pz).
The study consisted of a traditional “load-to-failure” test.
(3) Results: A statistically significant result was found for the effect of cantilever length, t(38) = 16.
23 (p < 0.
001), with this having a large effect size, d = 4.
68.
The 6 mm cantilever length (M = 442.
30, sd = 47.
49) was associated with a higher mean force at break than the 10 mm length (M = 215.
18, sd = 40.
74).
No significant effect was found for the type of zirconia: t(38) = 0.
31 (p = 0.
757), and d = 0.
10.
(4) Conclusions: All the components with cantilever lengths of 6 mm broke under forces higher than 250 N.
Cantilevers larger than 10 mm should be avoided.

Related Results

Effect of Hydrothermal Aging on Mechanical and Microstructural Properties of Zirconia Ceramics
Effect of Hydrothermal Aging on Mechanical and Microstructural Properties of Zirconia Ceramics
The mechanical and microstructural properties of monolithic zirconia ceramics are significant factors for their long-term clinical performance. This study aims to investigate the e...
Influence of sandblasting on zirconia in restorative dentistry
Influence of sandblasting on zirconia in restorative dentistry
La utilización de circona tetragonal policristalina estabilizada con 3 % mol de itria (3Y-TZP) para fabricar coronas e implantes ha sufrido una fuerte expansión recientemente debi...
Mechanical properties of co-doped zirconia ceramics
Mechanical properties of co-doped zirconia ceramics
Tetragonal polycrystalline zirconia, commonly stabilised with 3 mol% yttria (3Y-TZP), became one of the most interesting ceramics for biomedical applications due to its biocompatib...
Aplicabilidade dos sistemas CAD/CAM em Prótese Total: revisão de literatura
Aplicabilidade dos sistemas CAD/CAM em Prótese Total: revisão de literatura
Introdução: A tecnologia CAD/CAM possui múltiplas aplicações protéticas, incluindo a prótese total. Objetivos: realizar uma revisão de literatura sobre a aplicabilidade dos sistema...
Processing and properties of zirconia-CNT composites
Processing and properties of zirconia-CNT composites
In the last decades there has been growing interest in developing ceramic materials with high fracture toughness (Klc) and strength for structural applications. In the specific cas...
Micropatterned Silica Films with Nanohydroxyapatite for Y-TZP Implants
Micropatterned Silica Films with Nanohydroxyapatite for Y-TZP Implants
This investigation aimed at developing micropatterned silica thin films (MSTFs) containing nanohydroxyapatite (nano-HA) microaggregates that were not completely covered by silica s...
Comparative Evaluation of Fracture Strength of Implant Supported Crown Fabricated from CAD/CAM and 3D Printed Resin Matrix Ceramic
Comparative Evaluation of Fracture Strength of Implant Supported Crown Fabricated from CAD/CAM and 3D Printed Resin Matrix Ceramic
Objective: To compare fracture strength of screw-retained implant-supported crown of resin matrix ceramic when fabricated using CAD/CAM and 3D printing Material and method: vericom...

Back to Top