Javascript must be enabled to continue!
Fatigue Fracture Behavior of TA15 Alloy after Laser Marking
View through CrossRef
In order to study the effect of laser marking on the fatigue properties of TA15 titanium alloy, the alloy was marked at two depths respectively, and the low-cycle fatigue properties and fracture mechanism of TA15 titanium alloy after marking were analyzed and discussed. The results show that different degrees of marking pits appear on the surface of the alloy after laser marking, which is easy to cause local stress concentration. With the increase of power, the cross section shape of the bottom end of laser marking changes from a semi-arc shape to a sharp cone shape, resulting in high stress concentration phenomenon. The low cycle fatigue life of laser shallow marking specimens decreases by 62.7%, and that of laser deep marking specimens decreases by 86.4%. With the increase of the marking depth, the fatigue source area gradually becomes rough from smooth at the beginning, the divergence degree of cracks increases, the spacing of each crack in the initiation area increases, and the morphology becomes rough. The deeper the marking area is, the more driving force is provided for the initiation of cracks, and finally the fatigue performance deteriorates significantly.
Madison Academic Press
Title: Fatigue Fracture Behavior of TA15 Alloy after Laser Marking
Description:
In order to study the effect of laser marking on the fatigue properties of TA15 titanium alloy, the alloy was marked at two depths respectively, and the low-cycle fatigue properties and fracture mechanism of TA15 titanium alloy after marking were analyzed and discussed.
The results show that different degrees of marking pits appear on the surface of the alloy after laser marking, which is easy to cause local stress concentration.
With the increase of power, the cross section shape of the bottom end of laser marking changes from a semi-arc shape to a sharp cone shape, resulting in high stress concentration phenomenon.
The low cycle fatigue life of laser shallow marking specimens decreases by 62.
7%, and that of laser deep marking specimens decreases by 86.
4%.
With the increase of the marking depth, the fatigue source area gradually becomes rough from smooth at the beginning, the divergence degree of cracks increases, the spacing of each crack in the initiation area increases, and the morphology becomes rough.
The deeper the marking area is, the more driving force is provided for the initiation of cracks, and finally the fatigue performance deteriorates significantly.
Related Results
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference.
Abstract
Fractures are ubiquitous st...
EFEKTIVITAS YOGA UNTUK MENGURANGI FATIGUE PADA PASIEN KANKER YANG MENJALANI KEMOTERAPI
EFEKTIVITAS YOGA UNTUK MENGURANGI FATIGUE PADA PASIEN KANKER YANG MENJALANI KEMOTERAPI
ABSTRAKLatar Belakang : Cancer Related Fatigue (CRF) adalah manifestasi klinis yang serius dan gejala umum yang dialami oleh pasien kanker. Fatigue adalah salah satu yang paling se...
Fracture Modelling Using Seismic Based Fracture Intensity Volume, a Case Study in Middle East
Fracture Modelling Using Seismic Based Fracture Intensity Volume, a Case Study in Middle East
Abstract
In this paper, a case study in a fractured carbonate reservoir is presented to demonstrate the approach of fracture modeling using fracture intensity vol...
Sequential Propagation of Multiple Fractures in Horizontal Wells
Sequential Propagation of Multiple Fractures in Horizontal Wells
ABSTRACT:
Simultaneous fracturing and zipper fracturing of horizontal wells has rapidly evolved to the development of unconventional oil and gas. The fracture int...
Experimental Investigation on the Effects of Proppant Migration and Placement on the Conductivity in Rough Fractures
Experimental Investigation on the Effects of Proppant Migration and Placement on the Conductivity in Rough Fractures
ABSTRACT
Proppant conductivity was usually measured under static or designed proppant concentration. The ISO 13503-5 standard provides specific experimental proce...
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
In order to increase the accuracy of precise orbit determination for a single satellite or satellites in LEO formation, we propose using a LEO-to-GNSS laser interferometer, what we...
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Abstract
Laser light has a number of spectacular properties that make it useful for analytical spectrometry. One is that it has a high directionality (i.e. i...
Assessment of Objective and Subjective Fatigubility in Obese
Assessment of Objective and Subjective Fatigubility in Obese
Aim: This study aimed to quantify objective fatigue using the Long Distance Corridor Walk (2-Minute Walk Test and 400-Meter Walk Test) and evaluate subjective fatigue using the Fat...

