Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Transperineal Prostate Biopsy Targeted by Magnetic Resonance Imaging Cognitive Fusion

View through CrossRef
Prostate cancer is among the most frequently diagnosed cancers and a leading cause of cancer-related death in men. Currently, the most reliable and widely used imaging test for prostate cancer diagnosis is multiparametric pelvic magnetic resonance imaging (mpMRI). Modern biopsy techniques are based on the computerised merging of ultrasound and MRI images to provide better vision during the biopsy procedure (Fusion Biopsy). However, the method is expensive due to high equipment cost. Cognitive fusion of ultrasound and MRI images has recently emerged as a cheaper and easier alternative to computerised fusion. The aim of this prospective study is to perform an in-patient comparison of the systematic prostate biopsy procedure (SB) vs. cognitive fusion (CF) guided prostate biopsy method in terms of safety, ease of use, cancer detection rate and clinically significant cancer detection. We enrolled 103 patients with suspected prostate cancer that were biopsy naive, with PSA > 4 ng/dL and PIRADS score of 3, 4 or 5. All patients received a transperineal standard 12–18 cores systematic biopsy (SB) and a four-cores targeted cognitive fusion (CF) biopsy. Following the prostate biopsy, 68% of the patients were diagnosed with prostate cancer (70/103 patients). SB diagnosis rate was 62% while CF biopsy was slightly better with a 66% rate. There was a significant 20% increase in clinically significant prostate cancer detection rate for the CF compared to SB (p < 0.05) and a significant prostate cancer risk upgrade from the low to the intermediate risk category (13%, p = 0.041). Transperineal cognitive fusion targeted prostate biopsy is a straightforward biopsy method that is easy to perform and is a safe alternative to standard systematic biopsy with improved significant cancer detection accuracy. A combined targeted and systematic approach should be used for the best diagnostic results.
Title: Transperineal Prostate Biopsy Targeted by Magnetic Resonance Imaging Cognitive Fusion
Description:
Prostate cancer is among the most frequently diagnosed cancers and a leading cause of cancer-related death in men.
Currently, the most reliable and widely used imaging test for prostate cancer diagnosis is multiparametric pelvic magnetic resonance imaging (mpMRI).
Modern biopsy techniques are based on the computerised merging of ultrasound and MRI images to provide better vision during the biopsy procedure (Fusion Biopsy).
However, the method is expensive due to high equipment cost.
Cognitive fusion of ultrasound and MRI images has recently emerged as a cheaper and easier alternative to computerised fusion.
The aim of this prospective study is to perform an in-patient comparison of the systematic prostate biopsy procedure (SB) vs.
cognitive fusion (CF) guided prostate biopsy method in terms of safety, ease of use, cancer detection rate and clinically significant cancer detection.
We enrolled 103 patients with suspected prostate cancer that were biopsy naive, with PSA > 4 ng/dL and PIRADS score of 3, 4 or 5.
All patients received a transperineal standard 12–18 cores systematic biopsy (SB) and a four-cores targeted cognitive fusion (CF) biopsy.
Following the prostate biopsy, 68% of the patients were diagnosed with prostate cancer (70/103 patients).
SB diagnosis rate was 62% while CF biopsy was slightly better with a 66% rate.
There was a significant 20% increase in clinically significant prostate cancer detection rate for the CF compared to SB (p < 0.
05) and a significant prostate cancer risk upgrade from the low to the intermediate risk category (13%, p = 0.
041).
Transperineal cognitive fusion targeted prostate biopsy is a straightforward biopsy method that is easy to perform and is a safe alternative to standard systematic biopsy with improved significant cancer detection accuracy.
A combined targeted and systematic approach should be used for the best diagnostic results.

Related Results

Cost-effectiveness of MRI targeted biopsy strategies for diagnosing prostate cancer in Singapore
Cost-effectiveness of MRI targeted biopsy strategies for diagnosing prostate cancer in Singapore
AbstractBackgroundTo evaluate the cost-effectiveness of six diagnostic strategies involving magnetic resonance imaging (MRI) targeted biopsy for diagnosing prostate cancer in initi...
Analysis of the spatial distribution and clinical features of prostate cancer in transperineal prostate biopsy
Analysis of the spatial distribution and clinical features of prostate cancer in transperineal prostate biopsy
Abstract Background Recently, most studies on the spatial distribution of the prostate cancer are based on the samples confirmed by transrectal prostate biopsy (TRBx), whic...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Safety and feasibility of freehand transperineal prostate biopsy under local anesthesia
Safety and feasibility of freehand transperineal prostate biopsy under local anesthesia
Introduction: With the emergence of multidrug-resistant organisms causing urosepsis after transrectal biopsy of prostate, the need for an alternative approach has incre...
The 20-core prostate biopsy as an initial strategy: impact on the detection of prostatic cancer
The 20-core prostate biopsy as an initial strategy: impact on the detection of prostatic cancer
Introduction: To increase the detection rate of prostate cancer inrecent years, we examined the increase in the number of corestaken at initial prostate biopsy. We hypothesized tha...
The Nuclear Fusion Award
The Nuclear Fusion Award
The Nuclear Fusion Award ceremony for 2009 and 2010 award winners was held during the 23rd IAEA Fusion Energy Conference in Daejeon. This time, both 2009 and 2010 award winners w...

Back to Top