Introduction of a New Parameter for Evaluation of Digital Radiography System Performance
View through CrossRef
Background:
The aim of this study was to compare the image quality and radiation doses in various digital radiography systems using contrast-detail radiography (CDRAD) phantom.
Methods:
The image quality and radiation dose for seven different digital radiography systems were compared using the CDRAD phantom. Incident air kerma (IAK) values were measured for certain exposure settings in all digital radiography systems. The images from the CDRAD phantom were evaluated by three observers. The results were displayed in the form of a contrast-detail (CD) curve. In addition, the inverse image quality figure (IQFinv)-to-IAK ratios were used for quantitative comparison of different digital radiography system performance.
Results:
Results of this study showed that the CD curves cannot be suitable criterion for determining the performance of digital radiography systems. For this reason, IQFinv-to-radiation dose (IAK) ratios in a fixed radiation condition were used. The highest performance in terms of producing high-quality images and low radiation dose was related to X-ray unit 1 and the lowest performance was for X-ray unit 5.
Conclusion:
The ratio of IQFinv to IAK for performance evaluation of digital radiography systems is an innovation of this study. A digital radiography system with a higher IQFinv-to-IAK ratio is associated with lower patient dose and better image quality. Therefore, it is recommended to equip the new imaging centers with the systems that have higher IQFinv-to-IAK ratios.
Ovid Technologies (Wolters Kluwer Health)
Title: Introduction of a New Parameter for Evaluation of Digital Radiography System Performance
Description:
Background:
The aim of this study was to compare the image quality and radiation doses in various digital radiography systems using contrast-detail radiography (CDRAD) phantom.
Methods:
The image quality and radiation dose for seven different digital radiography systems were compared using the CDRAD phantom.
Incident air kerma (IAK) values were measured for certain exposure settings in all digital radiography systems.
The images from the CDRAD phantom were evaluated by three observers.
The results were displayed in the form of a contrast-detail (CD) curve.
In addition, the inverse image quality figure (IQFinv)-to-IAK ratios were used for quantitative comparison of different digital radiography system performance.
Results:
Results of this study showed that the CD curves cannot be suitable criterion for determining the performance of digital radiography systems.
For this reason, IQFinv-to-radiation dose (IAK) ratios in a fixed radiation condition were used.
The highest performance in terms of producing high-quality images and low radiation dose was related to X-ray unit 1 and the lowest performance was for X-ray unit 5.
Conclusion:
The ratio of IQFinv to IAK for performance evaluation of digital radiography systems is an innovation of this study.
A digital radiography system with a higher IQFinv-to-IAK ratio is associated with lower patient dose and better image quality.
Therefore, it is recommended to equip the new imaging centers with the systems that have higher IQFinv-to-IAK ratios.
Related Results
Orthopedic Injury Diagnosis Using Digital Radiography: A Retrospective Study
Orthopedic Injury Diagnosis Using Digital Radiography: A Retrospective Study
Background: Hundred patients were examined to determine the effectiveness of digital radiography in detecting Orthopedic injuries. The decisive findings showed that digital radiogr...
The role of chest radiography in the diagnosis of bacteriologically confirmed pulmonary tuberculosis in hospitalised Xpert MTB/RIF-negative patients
The role of chest radiography in the diagnosis of bacteriologically confirmed pulmonary tuberculosis in hospitalised Xpert MTB/RIF-negative patients
The role of chest radiography to diagnose active tuberculosis in symptomatic patients who have a negative Xpert MTB/RIF (Xpert) test result is unclear. This study aimed to assess t...
Digital Radiography vs Conventional Radiography: Is Digital Radiography in Compliance With the Code?
Digital Radiography vs Conventional Radiography: Is Digital Radiography in Compliance With the Code?
Savannah River Technology Center filmless radiographic imaging system specialists have been “champions” of filmless radiographic imaging at the Savannah River Site since 1993. Rece...
Eksistensi Digital Wedding Di Era Disrupsi Dalam Maqashid Syariah
Eksistensi Digital Wedding Di Era Disrupsi Dalam Maqashid Syariah
Abstract
The era of disruption has presented a new phenomenon in wedding procedures, namely digital weddings. The emergence of digital marriage raises questions about its validity...
Evaluation of the knowledge and application of diagnostic imaging modalities among veterinary surgeons in Nigerian veterinary medical schools
Evaluation of the knowledge and application of diagnostic imaging modalities among veterinary surgeons in Nigerian veterinary medical schools
The awareness, theoretical and practical knowledge of radiography, ultrasonography, magnetic resonance imaging (MRI), computed tomography (CT), nuclear medical imaging (NMI) and th...
Exploring the Frontiers of Synthetic Image-Based Deep Learning Training in Digital X-ray Radiography
Exploring the Frontiers of Synthetic Image-Based Deep Learning Training in Digital X-ray Radiography
Industrial radiography is a pivotal non-destructive testing (NDT) method that ensures quality and safety in a wide range of industrial sectors. Nevertheless, the conventional human...
Plain radiography, excretion radiography, and contrast radiography
Plain radiography, excretion radiography, and contrast radiography
Abstract
Plain radiography is both a primary abdominal examination technique and an initial component of subsequent excretion and contrast radiographic studies. Excr...
Simulating upright cervical lordosis in the supine position
Simulating upright cervical lordosis in the supine position
Cervical alignment or lordosis evolution is still attained by direct radiography in standing position because an ideal cervical curvature is essential to maintain a horizontal gaze...