Javascript must be enabled to continue!
OCT based evaluation of retinal changes in multiple sclerosis
View through CrossRef
Background: Optical coherence tomography is a non-invasive imaging technique routinely used in ophthalmology to visualize and quantify the layers of the retina. It also provides information on optic nerve head topography, peripapillary retinal nerve fibre layer thickness and macular volume which correlate with axonal loss. These measurements are of interest in optic neuropathies and in multiple sclerosis. The OCT parameters are now used as endpoints in neurologic clinical trials.Methods: A prospective study involving 30 patients of multiple sclerosis and equal number of age and sex matched controls were subjected to evaluation of retinal changes (peripapillary retinal nerve fiber layer and central macular thickness) using Zeiss Cirrus HD-OCT machine. The results collected were then subjected to statistical analysis.Results: Significant RNFL thinning was seen in patients of multiple sclerosis compared to the age and sex matched controls. Marked thinning was seen in superior and temporal quadrants of right eye (p value of 0.002 and 0.008 respectively) and all quadrants in left eye with a p value of < 0.001. Patients with multiple sclerosis for more than 5 yrs showed statistically significant RNFL thinning in the superior quadrant of right eye (p<.005), however, no such changes were seen in rest of the quadrants of right eye and in none of the quadrants of left eye Significant RNFL thinning was seen in the patients of multiple sclerosis without prior history of optic neuritis than patients with prior history of optic neuritis which was statistically significant with p value of .001.Conclusions: Patients with multiple sclerosis for more than 5 yrs showed statistically significant RNFL thinning in the superior quadrant of right eye (p<.005). Significant RNFL thinning was seen in the patients of multiple sclerosis without prior history of optic neuritis than patients with prior history of Optic neuritis which was statistically significant with p value of .001. No significant changes were seen in central macular thickness in multiple sclerosis compared to the controls which was corroborated by statistical analysis (p value of 0.37).
Title: OCT based evaluation of retinal changes in multiple sclerosis
Description:
Background: Optical coherence tomography is a non-invasive imaging technique routinely used in ophthalmology to visualize and quantify the layers of the retina.
It also provides information on optic nerve head topography, peripapillary retinal nerve fibre layer thickness and macular volume which correlate with axonal loss.
These measurements are of interest in optic neuropathies and in multiple sclerosis.
The OCT parameters are now used as endpoints in neurologic clinical trials.
Methods: A prospective study involving 30 patients of multiple sclerosis and equal number of age and sex matched controls were subjected to evaluation of retinal changes (peripapillary retinal nerve fiber layer and central macular thickness) using Zeiss Cirrus HD-OCT machine.
The results collected were then subjected to statistical analysis.
Results: Significant RNFL thinning was seen in patients of multiple sclerosis compared to the age and sex matched controls.
Marked thinning was seen in superior and temporal quadrants of right eye (p value of 0.
002 and 0.
008 respectively) and all quadrants in left eye with a p value of < 0.
001.
Patients with multiple sclerosis for more than 5 yrs showed statistically significant RNFL thinning in the superior quadrant of right eye (p<.
005), however, no such changes were seen in rest of the quadrants of right eye and in none of the quadrants of left eye Significant RNFL thinning was seen in the patients of multiple sclerosis without prior history of optic neuritis than patients with prior history of optic neuritis which was statistically significant with p value of .
001.
Conclusions: Patients with multiple sclerosis for more than 5 yrs showed statistically significant RNFL thinning in the superior quadrant of right eye (p<.
005).
Significant RNFL thinning was seen in the patients of multiple sclerosis without prior history of optic neuritis than patients with prior history of Optic neuritis which was statistically significant with p value of .
001.
No significant changes were seen in central macular thickness in multiple sclerosis compared to the controls which was corroborated by statistical analysis (p value of 0.
37).
Related Results
Retinal Oximetry
Retinal Oximetry
Abstract.Purpose:Malfunction of retinal blood flow or oxygenation is believed to be involved in various diseases. Among them are retinal vessel occlusions, diabetic retinopathy and...
Retinal oximetry in patients with ischaemic retinal diseases
Retinal oximetry in patients with ischaemic retinal diseases
AbstractThe retinal oximeter is a new tool for non‐invasive measurement of retinal oxygen saturation in humans. Several studies have investigated the associations between retinal o...
The EWS–Oct-4 fusion gene encodes a transforming gene
The EWS–Oct-4 fusion gene encodes a transforming gene
The t(6;22)(p21;q12) translocation associated with human bone and soft-tissue tumours results in a chimaeric molecule fusing the NTD (N-terminal domain) of the EWS (Ewing's sarcoma...
Composing the puzzle: a case of acute unilateral vision loss
Composing the puzzle: a case of acute unilateral vision loss
A 75‐year‐old Caucasian male, with a medical history of hypertension, diabetes, and dyslipidemia, presented to the emergency department with sudden complete vision loss in his left...
The relationship between ethnicity and Multiple Sclerosis characteristics in the United Kingdom: a UK MS Register study
The relationship between ethnicity and Multiple Sclerosis characteristics in the United Kingdom: a UK MS Register study
Abstract
Previous studies have suggested differences in Multiple Sclerosis severity between individuals from different ethnic backgrounds. Howeve...
Comparison of choroidal thickness using swept-source and spectral-domain optical coherence tomography in normal Indian eyes
Comparison of choroidal thickness using swept-source and spectral-domain optical coherence tomography in normal Indian eyes
BACKGROUND/AIMS:
Choroidal thickness measurements are reported to differ between spectral-domain optical coherence tomography (SD-OCT) and swept-source OCT (SS-OCT). Th...
e0392 Relationship between retinal vasculopathy and coronary artery disease
e0392 Relationship between retinal vasculopathy and coronary artery disease
Background and objective
Studies showed that atherosclerosis is a systemic disease. Parameters representing peripheral artery atherosclerosis, such as decreased a...
P197 Similarity and difference in in-stent neoatherosclerosis assessment between near-infrared spectroscopy and optical coherence tomography
P197 Similarity and difference in in-stent neoatherosclerosis assessment between near-infrared spectroscopy and optical coherence tomography
Abstract
Backgrounds
Near-infrared spectroscopy (NIRS) has been implicated to assess the composition of the atherosclerotic plaq...

