Javascript must be enabled to continue!
Effect of fixing distal radius fracture with volar locking palmar plates while preserving pronator quadratus
View through CrossRef
Background
L-shaped incision of pronator quadratus (PQ) muscle along its radial and distal borders was always taken for distal radius fractures reduction and internal fixation. Repair of the PQ muscle was always recommended at the end of operation for some instructive reasons. But repair of PQ is not satisfied because of poor quality of muscle and fascial tissues which may cause pain or impede forearm pronation and supination for post-operative scarring around PQ. Inserting the locking palmar plate to pass under the pronator quadratus muscle and the locking screws are inserted through miniincisions in pronator quadratus in some patients with distal radius fractures is a reasonable technique which can preserve the pronator quadratus. The purpose of this study was to evaluate and compare the clinical effects after volar plating of the distal radius fractures while preserving the pronator quadratus and pronator quadratus repair.
Methods
Between September 2010 and April 2012, 65 patients (42 males and 23 females; aged 20-68 years and a mean age of 42.5 years) with distal radius fracture underwent open reduction and internal fixation using the volar locking palmar plates (Depuy or Smith companies). The patients were classified as 23A-2 through 23C-3 according to the Orthopaedic Trauma Association (OTA) classifications. All surgeries were completed by the same trained team. The volar locking palmar plates of distal radius performed with preserving pronator quadratus group involved 30 patients including 19 males and 11 females and performed with pronator quadratus repair group involved 35 patients including 23 males and 12 females. We compared the two groups for wrist pain, forearm range of motion, grip strength, perioperative complications and wrist functional recovery score.
Results
The minimum follow-up for the whole cohort was one year. The differences between the two groups were significant with regard to wrist pain, forearm range of motion, grip strength and wrist function at 1, 2, and 6 weeks postoperatively, but insignificant at 6 and 12 months postoperatively. No significant differences were found in the perioperative complications and radiographs postoperatively.
Conclusions
Preservation of the pronator quadratus muscle is a satisfactory method for the treatment of majority of the fractures of the distal radius with volar locking palmar plates, as this technique can yield better early wrist function and shorten the rehabilitation.
Ovid Technologies (Wolters Kluwer Health)
Title: Effect of fixing distal radius fracture with volar locking palmar plates while preserving pronator quadratus
Description:
Background
L-shaped incision of pronator quadratus (PQ) muscle along its radial and distal borders was always taken for distal radius fractures reduction and internal fixation.
Repair of the PQ muscle was always recommended at the end of operation for some instructive reasons.
But repair of PQ is not satisfied because of poor quality of muscle and fascial tissues which may cause pain or impede forearm pronation and supination for post-operative scarring around PQ.
Inserting the locking palmar plate to pass under the pronator quadratus muscle and the locking screws are inserted through miniincisions in pronator quadratus in some patients with distal radius fractures is a reasonable technique which can preserve the pronator quadratus.
The purpose of this study was to evaluate and compare the clinical effects after volar plating of the distal radius fractures while preserving the pronator quadratus and pronator quadratus repair.
Methods
Between September 2010 and April 2012, 65 patients (42 males and 23 females; aged 20-68 years and a mean age of 42.
5 years) with distal radius fracture underwent open reduction and internal fixation using the volar locking palmar plates (Depuy or Smith companies).
The patients were classified as 23A-2 through 23C-3 according to the Orthopaedic Trauma Association (OTA) classifications.
All surgeries were completed by the same trained team.
The volar locking palmar plates of distal radius performed with preserving pronator quadratus group involved 30 patients including 19 males and 11 females and performed with pronator quadratus repair group involved 35 patients including 23 males and 12 females.
We compared the two groups for wrist pain, forearm range of motion, grip strength, perioperative complications and wrist functional recovery score.
Results
The minimum follow-up for the whole cohort was one year.
The differences between the two groups were significant with regard to wrist pain, forearm range of motion, grip strength and wrist function at 1, 2, and 6 weeks postoperatively, but insignificant at 6 and 12 months postoperatively.
No significant differences were found in the perioperative complications and radiographs postoperatively.
Conclusions
Preservation of the pronator quadratus muscle is a satisfactory method for the treatment of majority of the fractures of the distal radius with volar locking palmar plates, as this technique can yield better early wrist function and shorten the rehabilitation.
Related Results
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Introduction: The aim of this study is to illustrate a case in which the use of a dorsal spanning plate followed by volar plating may be indicated in the setting of a complex intra...
Flexor Pollicis Longus Tendon Rupture after Distal Radius Volar Plating and Reconstruction with Interpositional Palmaris Tendon Graft: A Case Report
Flexor Pollicis Longus Tendon Rupture after Distal Radius Volar Plating and Reconstruction with Interpositional Palmaris Tendon Graft: A Case Report
Introduction: Distal radius fractures constitute one of the most prevalent upper extremity orthopedic injuries, predominantly resulting from falls onto an outstretched hand with an...
A novel technique for full anatomic restoration of volar tilt in distal radius fracture
A novel technique for full anatomic restoration of volar tilt in distal radius fracture
Abstract
Objective: The aim of this study was to present a technique that allows the surgeon to easily and reliably achieve volar tilt in dorsally displaced distal radius fract...
SURGICAL OUTCOMES OF VOLAR LOCKING PLATE VERSUS K-WIRES FIXATION FOR DISTAL RADIUS FRACTURES
SURGICAL OUTCOMES OF VOLAR LOCKING PLATE VERSUS K-WIRES FIXATION FOR DISTAL RADIUS FRACTURES
Background and Objective: The most common hand fractures among adult population are distal radius fractures and optimal management of these fractures remains controversial. Several...
Treatment of distal radius fractures with steel plate fixation through the bone channel of the inferior pronator quadratus
Treatment of distal radius fractures with steel plate fixation through the bone channel of the inferior pronator quadratus
Abstract
Objective: The study aimed to investigate the effect of internal fixation with steel plate through the inferior pronator quadratus bone channel on wrist function i...
Distal Radius Volar T Plate Versus Distal Clavicle Pre-Contoured Locking Plate in Neer 2b Distal Clavicle Fractur: A Randomized Controlled Trial
Distal Radius Volar T Plate Versus Distal Clavicle Pre-Contoured Locking Plate in Neer 2b Distal Clavicle Fractur: A Randomized Controlled Trial
Background: The purpose of the current study was to compare the clinical and radiographic outcomes of distal radius volar T plate and pre-contoured locking plate in distal clavicle...
FUNCTIONAL OUTCOMES OF DISTAL RADIUS FRACTURES MANAGED WITH 2.7MM VARIABLE ANGLE VOLAR LOCKING COMPRESSION PLATES
FUNCTIONAL OUTCOMES OF DISTAL RADIUS FRACTURES MANAGED WITH 2.7MM VARIABLE ANGLE VOLAR LOCKING COMPRESSION PLATES
Objective: About 15 to 17 % of all fractures presenting to emergency department constitutes the distal radius fracture. Intra-articular fracture of distal radius remains one of the...
Outcome of volar Barton fractures of distal radius managed with open reduction and internal fixation with volar locking plate
Outcome of volar Barton fractures of distal radius managed with open reduction and internal fixation with volar locking plate
Background: Volar Barton fractures of distal radius almost always require a surgical fixation. Near anatomical reduction and a stout fixation is imperative for good outcome. The pr...

