Thermal protective performance of protective clothing used for low radiant heat protection

View through CrossRef
A laboratory simulation was performed to study the thermal protective performance of fabric systems under low level thermal hazards in the range of 6.3—8.3 kW/m 2 . Two approaches were used. The first used a method similar to the ASTM F 1939, radiant heat resistance test, while the second used a modification designed to capture the contribution to skin burn injury due to energy stored in the test specimens being released after the direct exposure had ended. Both dry and wet specimens were tested. In order to accommodate the prolonged exposure time a water cooled heat flux sensor was used to calibrate the radiant heat source and measure the energy directly transmitted through during the exposure and discharged later from the fabric systems. The Henriques Burn Integral (HBI) was adopted and programmed with a three layer skin model to predict the time required to achieve a second degree skin burn injury. The study investigated the thermal protection provided by the clothing with different layering and examined the effect of moisture under low level radiant heat exposures. In addition, the physiological burden associated with wearing the clothing was predicted and compared. The results obtained show the difference in measured protection level under low radiant heat from these two approaches and demonstrate that the stored thermal energy released from the clothing system significantly lowers the measured thermal protective performance.
Title: Thermal protective performance of protective clothing used for low radiant heat protection
Description:
A laboratory simulation was performed to study the thermal protective performance of fabric systems under low level thermal hazards in the range of 6.
3—8.
3 kW/m 2 .
Two approaches were used.
The first used a method similar to the ASTM F 1939, radiant heat resistance test, while the second used a modification designed to capture the contribution to skin burn injury due to energy stored in the test specimens being released after the direct exposure had ended.
Both dry and wet specimens were tested.
In order to accommodate the prolonged exposure time a water cooled heat flux sensor was used to calibrate the radiant heat source and measure the energy directly transmitted through during the exposure and discharged later from the fabric systems.
The Henriques Burn Integral (HBI) was adopted and programmed with a three layer skin model to predict the time required to achieve a second degree skin burn injury.
The study investigated the thermal protection provided by the clothing with different layering and examined the effect of moisture under low level radiant heat exposures.
In addition, the physiological burden associated with wearing the clothing was predicted and compared.
The results obtained show the difference in measured protection level under low radiant heat from these two approaches and demonstrate that the stored thermal energy released from the clothing system significantly lowers the measured thermal protective performance.

Related Results

Radiant Heat Loss versus Radiant Heat Gain in Premature Neonates under Radiant Warmers
Radiant Heat Loss versus Radiant Heat Gain in Premature Neonates under Radiant Warmers
Premature infants nursed on open radiant warmer beds are exposed to short-wavelength infrared power density distributed evenly over the bed surface. Additionally, infants’ sides ar...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Thermal energy storage with tunnels in different subsurface conditions
Thermal energy storage with tunnels in different subsurface conditions
The widespread use of the underground and global climate change impact the urban subsurface temperature. Changes in the subsurface environment can affect the performance of undergr...
Analyzing stored thermal energy and thermal protective performance of clothing
Analyzing stored thermal energy and thermal protective performance of clothing
Protective clothing can store large amounts of energy when exposed to thermal (heat, flame) hazards. After exposure, the stored thermal energy discharges naturally—or may be forced...
Thermal Performance of Wall Systems Utilizing Radiant Barriers
Thermal Performance of Wall Systems Utilizing Radiant Barriers
Typical brick veneer wall assemblies contain an air space to provide drainage inside the wall. This air cavity results in heat transfer through the wall via conduction, convection,...
DTRS56-04-T-0005A Radiant Heat Attenuation by Clothing and Human Tolerance to Radiant Heat
DTRS56-04-T-0005A Radiant Heat Attenuation by Clothing and Human Tolerance to Radiant Heat
A series of tests involving the exposing mannequins clothed with normal civilian clothing to a 10 ft. x 10 ft. LNG pool fire was conducted. Both single layer clothing and double la...
A Brief Review on Radiant Cooling Panel with Different Chilled Water Pipe Configurations
A Brief Review on Radiant Cooling Panel with Different Chilled Water Pipe Configurations
Radiant cooling systems are commonly applied in commercial applications because of their energy-saving potential. This potential can be further enhanced by evaluating the cooling p...