Javascript must be enabled to continue!
Assessment of Air Quality Parameters at Different Locations of Tangail Sadar Upazila, Tangail
View through CrossRef
The study was conducted to investigate the concentration of PM2.5, PM10, CH4, CO2, CO, SO2 in the air of Tangail Sadar Upazila, Tangail. In the study area air quality data has been collected from eight sampling stations namely MBSTU campus, Baby stand, Nirala more, New bus stand, Rabna bypass, College gate, Old bus stand, Nogor jalfoi during dry season. The air quality data collected by using Aeroqual S 500 series. The concentrations of PM2.5, PM10, CH4, CO2, CO, SO2 found in air were ranged from 0.03-0.06, 0.04-0.10, 12.3-36, 919-1238.2, 0.00- 2.61, 0.00-0.48 mg/m3, respectively. The concentration of PM2.5, PM10, CO, SO2 that have been found were higher than Bangladesh standard and WHO guideline. Their sources could be the motor vehicles, road dust, coal burning, road construction, open dumping of solid waste in Tangail Sadar Upazila. Appropriate engine design control strategies and maintenance services should be introduced for reducing emission. Efficient solid waste management system should be introduced to control emission from construction sources.
Environ. Sci. & Natural Resources, 13(1&2): 118-122, 2020
Bangladesh Journals Online (JOL)
Title: Assessment of Air Quality Parameters at Different Locations of Tangail Sadar Upazila, Tangail
Description:
The study was conducted to investigate the concentration of PM2.
5, PM10, CH4, CO2, CO, SO2 in the air of Tangail Sadar Upazila, Tangail.
In the study area air quality data has been collected from eight sampling stations namely MBSTU campus, Baby stand, Nirala more, New bus stand, Rabna bypass, College gate, Old bus stand, Nogor jalfoi during dry season.
The air quality data collected by using Aeroqual S 500 series.
The concentrations of PM2.
5, PM10, CH4, CO2, CO, SO2 found in air were ranged from 0.
03-0.
06, 0.
04-0.
10, 12.
3-36, 919-1238.
2, 0.
00- 2.
61, 0.
00-0.
48 mg/m3, respectively.
The concentration of PM2.
5, PM10, CO, SO2 that have been found were higher than Bangladesh standard and WHO guideline.
Their sources could be the motor vehicles, road dust, coal burning, road construction, open dumping of solid waste in Tangail Sadar Upazila.
Appropriate engine design control strategies and maintenance services should be introduced for reducing emission.
Efficient solid waste management system should be introduced to control emission from construction sources.
Environ.
Sci.
& Natural Resources, 13(1&2): 118-122, 2020.
Related Results
PREVALENCE OF VETERINARY ECTOPARASITES IN BARURA, CHANDINA AND LAKSAM UPAZILAS OF CUMILLA DISTRICT, BANGLADESH
PREVALENCE OF VETERINARY ECTOPARASITES IN BARURA, CHANDINA AND LAKSAM UPAZILAS OF CUMILLA DISTRICT, BANGLADESH
Studies on the prevalence of veterinary ectoparasitic insects and arachnids of cattle and goats in three upazila of Cumilla district was conducted for one year during December 2013...
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Exposure to volatile organic compounds (VOC) in workplaces can cause acute effects such as irritation of the skin, the eyes, the mouth, and the nose. Some products may also cause c...
Air convection in coarse blocky permafrost : a numerical modelling approach to improve the understanding of the ground thermal regime
Air convection in coarse blocky permafrost : a numerical modelling approach to improve the understanding of the ground thermal regime
Permafrost is a thermal phenomenon, defined as subsurface material with a temperature remaining below 0°C for at least two consecutive years. Permafrost occurs at high latitudes an...
Élimination des vapeurs toxiques par oxydation : développement de procédures d'évaluation des systèmes de purification de l'air des conduits de ventilation
Élimination des vapeurs toxiques par oxydation : développement de procédures d'évaluation des systèmes de purification de l'air des conduits de ventilation
L'exposition à des composés organiques volatils (COV) dans les lieux de travail peut avoir des effets aigus, notamment sous forme d'irritation de la peau, des yeux, de la bouche et...
Study of Honeycomb Air Curtain for a Freezer Room to Enhance Protection against Warm Air Infiltration
Study of Honeycomb Air Curtain for a Freezer Room to Enhance Protection against Warm Air Infiltration
The objective of this research is to present the energy-saving effect of applying an air curtain to prevent the penetration of warm air through a freezer door. Retail business is h...
Tangail Saree as Geographical Indication of Bangladesh
Tangail Saree as Geographical Indication of Bangladesh
Tangail Sarees, a six-yard dress worn by women in South Asian countries especially Bangladesh, India, Sri Lanka, and Nepal, are renowned due to their unique weaving techniques, des...
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Abstract
Introduction
Among the most frequently used anticoagulants in hematological testing are tetra-acetic acid (EDTA), sodium citrate, and sodium heparin. However, there is a n...
Rapid estimation of climate-air quality interactions in integrated assessment using a response surface model
Rapid estimation of climate-air quality interactions in integrated assessment using a response surface model
Air quality and climate change are substantial and linked sustainability challenges, and there is a need for improved tools to assess the implications of addressing them in combina...