Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

SEISMIC FRAGILITY ASSESSMENT AND RETROFIT OF A GOVERNMENT HOSPITAL BUILDING IN CHITTAGONG, BANGLADESH

View through CrossRef
Chittagong Medical College Hospital (CMCH) is one of the most important government hospitals in Bangladesh. It is located in the heart of Chittagong city, the only port city of Bangladesh. Bangladesh National Building Code (BNBC) is the only official document, which has been used since 1993 as guidelines for seismic design of buildings. As per the guidelines of BNBC, the CMCH building was designed for an earthquake ground motion having a return period of 200 years. However, the revised version of BNBC has suggested that the building structures shall be designed for an earthquake ground motion having a return period of 2475 years. It is mentioned that a single seismic performance objective, the life safety, of the building is considered in both versions of BNBC. Considering the significant importance of CMCH building in providing the emergency facilities during and after the earthquake, it is indispensable to evaluate its seismic vulnerability for the two types of earthquake ground motion records having return period of 200 (Type-I) and 2475 (Type-II) years. In this regard, this paper deals with the seismic vulnerability assessment of the existing ancillary building (AB) of CMCH. The seismic vulnerability of building is usually expressed in the form of fragility curves, which display the conditional probability that the structural demand (structural response) caused by various levels of ground shaking exceeds the structural capacity defined by a damage state. The analytical method based on elastic response spectrum analyses results is used in evaluating the seismic fragility curves of the building. To the end, 3-D finite element model of the building subjected to 18 ground motion records having PGA of 0.325g to 0.785g has been used in theresponse spectrum analysis in order to evaluate its inter-story-drift ratio (IDR), an engineeringdemand parameter (EDP) for developing fragility curves. The analytical results have shown thatstructural deficiencies exist in the existing ancillary building (AB) for the Type-II earthquakeground motion record, which requires the building to be retrofitted to ensure that the existingancillary building (AB) becomes functional during and after the Type-II earthquake groundmotion record.
Title: SEISMIC FRAGILITY ASSESSMENT AND RETROFIT OF A GOVERNMENT HOSPITAL BUILDING IN CHITTAGONG, BANGLADESH
Description:
Chittagong Medical College Hospital (CMCH) is one of the most important government hospitals in Bangladesh.
It is located in the heart of Chittagong city, the only port city of Bangladesh.
Bangladesh National Building Code (BNBC) is the only official document, which has been used since 1993 as guidelines for seismic design of buildings.
As per the guidelines of BNBC, the CMCH building was designed for an earthquake ground motion having a return period of 200 years.
However, the revised version of BNBC has suggested that the building structures shall be designed for an earthquake ground motion having a return period of 2475 years.
It is mentioned that a single seismic performance objective, the life safety, of the building is considered in both versions of BNBC.
Considering the significant importance of CMCH building in providing the emergency facilities during and after the earthquake, it is indispensable to evaluate its seismic vulnerability for the two types of earthquake ground motion records having return period of 200 (Type-I) and 2475 (Type-II) years.
In this regard, this paper deals with the seismic vulnerability assessment of the existing ancillary building (AB) of CMCH.
The seismic vulnerability of building is usually expressed in the form of fragility curves, which display the conditional probability that the structural demand (structural response) caused by various levels of ground shaking exceeds the structural capacity defined by a damage state.
The analytical method based on elastic response spectrum analyses results is used in evaluating the seismic fragility curves of the building.
To the end, 3-D finite element model of the building subjected to 18 ground motion records having PGA of 0.
325g to 0.
785g has been used in theresponse spectrum analysis in order to evaluate its inter-story-drift ratio (IDR), an engineeringdemand parameter (EDP) for developing fragility curves.
The analytical results have shown thatstructural deficiencies exist in the existing ancillary building (AB) for the Type-II earthquakeground motion record, which requires the building to be retrofitted to ensure that the existingancillary building (AB) becomes functional during and after the Type-II earthquake groundmotion record.

Related Results

SEISMIC FRAGILITY ASSESSMENT AND RETROFIT OF A GOVERNMENT HOSPITAL BUILDING IN CHITTAGONG, BANGLADESH
SEISMIC FRAGILITY ASSESSMENT AND RETROFIT OF A GOVERNMENT HOSPITAL BUILDING IN CHITTAGONG, BANGLADESH
Chittagong Medical College Hospital (CMCH) is one of the most important government hospitals in Bangladesh. It is located in the heart of Chittagong city, the only port city of Ban...
4D Seismic on Gullfaks
4D Seismic on Gullfaks
SUMMARY New technologies are rapidly emerging helping to obtain optimal drainage of large reservoirs. 4D seismic is such a reservoir monitoring technique. The phy...
Seismic Frequency Enhancement for Mapping and Reservoir Characterization of Arab Formation: Case Study Onshore UAE
Seismic Frequency Enhancement for Mapping and Reservoir Characterization of Arab Formation: Case Study Onshore UAE
Abstract Mapping and discrimination of Upper Jurassic Arab reservoirs (Arab A/B/C and D) in this 3D seismic onshore field of Abu Dhabi, is very sensitive to the seis...
Integrated Hydrocarbon Detection Based on Full Frequency Pre-Stack Seismic Inversion
Integrated Hydrocarbon Detection Based on Full Frequency Pre-Stack Seismic Inversion
Abstract To improve the accuracy of hydrocarbon detection, seismic amplitude variation with offset (AVO), seismic amplitude variation with frequency (AVF), and direc...
How far can low emission retrofit of terraced housing in Northern Ireland go?
How far can low emission retrofit of terraced housing in Northern Ireland go?
Abstract With both global and national targets to reduce greenhouse gas (GHG) emissions the improvement of existing buildings will be key to realising these ambition...
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract Introduction Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
Seismic retrofit of steel frame structures
Seismic retrofit of steel frame structures
Abstract:Moment resisting frames are considered as an effective seismic force resisting system that is used for steel structures. Some of these structures that were built in high s...
General classification of seismic protection systems of buildings and structures
General classification of seismic protection systems of buildings and structures
The issues of ensuring the seismic resistance of buildings and structures hold a leading position despite significant achievements in this area. This is confirmed by the significan...

Back to Top