Javascript must be enabled to continue!
Electronic working length determination in primary teeth by Propex and Digital Signal Processing
View through CrossRef
AbstractThe purpose of this study was to evaluate the accuracy of electronic apex locators Digital Signal Processing (DSP) and ProPex, for root canal length determination in primary teeth. Fifteen primary molars (a total of 34 root canals) were divided into two groups: Group I – without physiological resorption (n = 16); and Group II – with physiological resorption (n = 18). The length of each canal was measured by introducing a file until its tip was visible and then it was retracted 1 mm. For electronic measurement, the devices were set to 1 mm short of the apical resorption. The data were analysed statistically using the intraclass correlation coefficient (ICC). Results showed that the ICC was high for both electronic apex locators in all situations – with (ICC: DSP = 0.82 and Propex = 0.89) or without resorption (ICC: DSP = 0.92 and Propex = 0.90). Both apex locators were extremely accurate in determining the working length in primary teeth, both with or without physiological resorption.
Title: Electronic working length determination in primary teeth by Propex and Digital Signal Processing
Description:
AbstractThe purpose of this study was to evaluate the accuracy of electronic apex locators Digital Signal Processing (DSP) and ProPex, for root canal length determination in primary teeth.
Fifteen primary molars (a total of 34 root canals) were divided into two groups: Group I – without physiological resorption (n = 16); and Group II – with physiological resorption (n = 18).
The length of each canal was measured by introducing a file until its tip was visible and then it was retracted 1 mm.
For electronic measurement, the devices were set to 1 mm short of the apical resorption.
The data were analysed statistically using the intraclass correlation coefficient (ICC).
Results showed that the ICC was high for both electronic apex locators in all situations – with (ICC: DSP = 0.
82 and Propex = 0.
89) or without resorption (ICC: DSP = 0.
92 and Propex = 0.
90).
Both apex locators were extremely accurate in determining the working length in primary teeth, both with or without physiological resorption.
Related Results
In vitro assessment of the accuracy of three electronic apex locators
In vitro assessment of the accuracy of three electronic apex locators
Aim of this in vitro study was to compare accuracy of three electronic apex locators (EALs) (ES-02, ES-03 and ProPex) in root canals of extracted human teeth utilizing two meter re...
In vitro assessment of the accuracy of three electronic apex locators
In vitro assessment of the accuracy of three electronic apex locators
Aim of this in vitro study was to compare accuracy of three electronic apex locators (EALs) (ES-02, ES-03 and ProPex) in root canals of extracted human teeth utilizing two meter re...
Accuracy of two electronic apex locators: in vivo and in vitro study
Accuracy of two electronic apex locators: in vivo and in vitro study
The present study proposed the comparison of the reading between the in vivo and in vitro models during the evaluation of Root ZX II foramen locators and Propex II. The localizatio...
Pulp and periodontal healing of laterally luxated permanent teeth: results after 4 years
Pulp and periodontal healing of laterally luxated permanent teeth: results after 4 years
Abstract – Aim: To evaluate the pulp and periodontal healing of laterally luxated permanent teeth.Material and methods: Patients presenting with lateral luxation of permanent te...
Positioning of anterior teeth in removable dentures
Positioning of anterior teeth in removable dentures
Introduction The aim of this paper was to present methods of placement of artificial anterior teeth in edentulous individuals. The following review takes account of the majority of...
Comparison of Working Length Determination in Mandibular Single-Rooted Teeth
Comparison of Working Length Determination in Mandibular Single-Rooted Teeth
OBJECTIVES: The objective of this study was to compare working length calculated with conventional radiographs and an electronic apex locator (IPEX II) during the root canal treatm...
Numerical analysis of magnetic grease seal pole teeth optimization based on pressure bearing capacity
Numerical analysis of magnetic grease seal pole teeth optimization based on pressure bearing capacity
Abstract
The static magnetic field model of the magnetic grease seal was established by the nonlinear magnetic field finite element method. The influence of three ty...
The Predicting Power Of Digital Reading Attitudes Of Primary School Teacher Candidates’ Digital Reading Attitudes On Their Digital Literacy
The Predicting Power Of Digital Reading Attitudes Of Primary School Teacher Candidates’ Digital Reading Attitudes On Their Digital Literacy
In this study, it was is aimed to examine the predictive power of primary school teacher candidates’ digital reading attitudes on their digital literacy. The relational survey mode...


