Wear Simulation of Metal-on-Metal Hip Replacements With Frictional Contact
View through CrossRef
Preclinical wear evaluation is extremely important in hip replacements, wear being one of the main causes of failure. Experimental tests are attractive but highly cost demanding; thus predictive models have been proposed in the literature, mainly based on finite element simulations. In such simulations, the effect of friction is usually disregarded, as it is considered not to affect the contact pressure distribution. However, a frictional contact could also result in a shift of the location of the nominal contact area, which can thus modify the wear maps. The aim of this study is to investigate this effect in wear prediction for metal-on-metal implants. Wear assessment was based on a purpose-developed mathematical model, extension of a previous one proposed by the same authors for metal-on-plastic implants. The innovative aspect of the present study consists in the implementation of a modified location of the nominal contact point due to friction, which takes advantage of the analytical formulation of the wear model. Simulations were carried out aimed at comparing total and resurfacing hip replacements under several gait conditions. The results highlighted that the adoption of a frictional contact yields lower linear wear rates and wider worn areas, while for the adopted friction coefficient (f=0.2), the total wear volume remains almost unchanged. The comparison between total and resurfacing replacements showed higher scaled wear volumes (wear volume divided by wear factor) for the latter, in agreement with the literature. The effect of the boundary conditions (in vivo versus in vitro) was also investigated remarking their influence on implant wear and the need to apply more physiological-like conditions in hip simulators. In conclusion although friction is usually neglected in numerical wear predictions, as it does not affect markedly the contact pressure distribution, its effect in the location of the theoretical contact point was observed to influence wear maps. This achievement could be useful for increasing the correlation between numerical and experimental simulations, usually based on the total wear volume. In order to improve the model reliability, future studies will be devoted to implement the geometry update by combining the present model to finite element analyses. On the other hand, further experimental investigations are required to get out from the wide dispersion of wear factors reported in the literature.
Title: Wear Simulation of Metal-on-Metal Hip Replacements With Frictional Contact
Description:
Preclinical wear evaluation is extremely important in hip replacements, wear being one of the main causes of failure.
Experimental tests are attractive but highly cost demanding; thus predictive models have been proposed in the literature, mainly based on finite element simulations.
In such simulations, the effect of friction is usually disregarded, as it is considered not to affect the contact pressure distribution.
However, a frictional contact could also result in a shift of the location of the nominal contact area, which can thus modify the wear maps.
The aim of this study is to investigate this effect in wear prediction for metal-on-metal implants.
Wear assessment was based on a purpose-developed mathematical model, extension of a previous one proposed by the same authors for metal-on-plastic implants.
The innovative aspect of the present study consists in the implementation of a modified location of the nominal contact point due to friction, which takes advantage of the analytical formulation of the wear model.
Simulations were carried out aimed at comparing total and resurfacing hip replacements under several gait conditions.
The results highlighted that the adoption of a frictional contact yields lower linear wear rates and wider worn areas, while for the adopted friction coefficient (f=0.
2), the total wear volume remains almost unchanged.
The comparison between total and resurfacing replacements showed higher scaled wear volumes (wear volume divided by wear factor) for the latter, in agreement with the literature.
The effect of the boundary conditions (in vivo versus in vitro) was also investigated remarking their influence on implant wear and the need to apply more physiological-like conditions in hip simulators.
In conclusion although friction is usually neglected in numerical wear predictions, as it does not affect markedly the contact pressure distribution, its effect in the location of the theoretical contact point was observed to influence wear maps.
This achievement could be useful for increasing the correlation between numerical and experimental simulations, usually based on the total wear volume.
In order to improve the model reliability, future studies will be devoted to implement the geometry update by combining the present model to finite element analyses.
On the other hand, further experimental investigations are required to get out from the wide dispersion of wear factors reported in the literature.
Related Results
Physiological and biomechanical factors contributing to the hip adduction angle in female runners
Physiological and biomechanical factors contributing to the hip adduction angle in female runners
Running is a popular form of exercise that is accompanied by many health benefits. However, running also comes with a risk of overuse injuries. Women have a higher risk for overuse...
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
This paper explores South African hip-hop activist Emile YX?'s work to suggest that he presents an alternative take on mainstream US and South African hip-hop. While it is arguable...
ERROR ESTIMATION FOR A PIEZOELECTRIC CONTACT PROBLEM WITH WEAR AND LONG MEMORY
ERROR ESTIMATION FOR A PIEZOELECTRIC CONTACT PROBLEM WITH WEAR AND LONG MEMORY
We study a mathematical model for a quasistatic behavior of electro-viscoelastic materials. The problem is related to highly nonlinear and non-smooth phenomena like contact, fricti...
Association of Hip Radiograph Findings With Pain and Function in Patients Presenting With Low Back Pain
Association of Hip Radiograph Findings With Pain and Function in Patients Presenting With Low Back Pain
AbstractBackgroundRelationships between low back pain (LBP) and the hip in patient cohorts have been described primarily in patients with moderate to severe hip osteoarthritis (OA)...
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
Abstract
Despite advancements in fracture prediction tools and osteoporosis management, hip fractures remain a significant consequence of bone fr...
Effects of different factors on the friction and wear mechanical properties of titanium alloy materials with cortical bones at near service conditions
Effects of different factors on the friction and wear mechanical properties of titanium alloy materials with cortical bones at near service conditions
Abstract
Artificial joint is one of the most effective methods to treat joint injuries. The service performance of artificial joints is gradually bad due to the wear of art...
Study on the Theory and Method of Combined Casing Wear Resistance in Deep & Ultra-Deep Well Drilling
Study on the Theory and Method of Combined Casing Wear Resistance in Deep & Ultra-Deep Well Drilling
Abstract
The high and steep structure of piedmont areas in Tarim oil field bring serious casing wear problem. Casing wear is one of the important reasons for the ...
Comparison of muscle activation of hip belt squat and barbell back squat techniques
Comparison of muscle activation of hip belt squat and barbell back squat techniques
BACKGROUND: Hip belt squats are believed to have been introduced in 1970. By removing the load from the shoulders and upper trapezius, the hip belt squat places emphasis on the leg...