Javascript must be enabled to continue!
In Vivo 3‐Dimensional Glenohumeral Joint Geometry Based Upon Magnetic Resonance Imaging and Computed Tomography Analysis Shows Deeper, Thicker, and Taller Glenoid Labrum Morphology at 12 O’Clock Position in Healthy Young Adults
View through CrossRef
Purpose
To investigate location‐ and sex‐specific glenoid labrum morphology of healthy young adults in vivo, and the labrum's effects on depth and radius of curvature (ROC) of the glenohumeral joint.
Methods
Healthy young adults with no history of shoulder surgery, injury, or instability underwent computed tomography and magnetic resonance imaging scans. Bone, cartilage, and labrum tissues were segmented from the scans and used to create 3‐dimensional models for each participant. Measurements were made on the coregistered 3‐dimensional models. The labral thickness, height, and depth were expressed according to a clockface on the glenoid (3, 6, 9, and 12 o'clock locations). Glenoid depth and ROC were also measured. Comparisons were made between sexes and among clockface locations.
Results
Sixty shoulders of 30 individuals (15 males/15 females, average age: 25 ± 7 years, body mass Index: 25.4 kg/m
2
) were included. Repeated segmentation of a subset of the data showed the average absolute differences in labrum depth ranged from 0.3 to 0.4 mm, the labrum thickness differences ranged from 0.3 to 0.8 mm, and the labrum height differences ranged from 0.4 to 0.8 mm between the original and resegmented scans. For the complete dataset, no location‐specific differences in labrum morphology were found between males and females. The 12 o'clock location was at least 5.0 mm deeper, 4.3 mm thicker, and 8.4 mm taller than any other clockface location (all
P
< .001). The labrum increased the average depth of the glenoid between 2.4 and 5.6 mm in the anterior/posterior and superior/inferior locations, respectively (
P
< .001), contributing an average of 60.1% of the overall glenoid depth, and decreasing the average ROC by 22.6 mm in the anterior/posterior locations and by 8.8 mm in the superior/inferior locations.
Conclusions
The labrum in young healthy adults was found to be larger than previously reported in cadaver studies. The labrum at 12 o'clock is deeper, thicker, and taller than at other locations; however, no location‐specific differences were found between men and women. The labrum contributed significantly to the depth and created a more congruent joint by minimizing differences between humerus and glenoid ROC.
Clinical Relevance
Improved understanding of the morphology of the glenoid labrum in young adults may be used to guide surgical repair and design of anatomical shoulder replacements.
Title: In Vivo 3‐Dimensional Glenohumeral Joint Geometry Based Upon Magnetic Resonance Imaging and Computed Tomography Analysis Shows Deeper, Thicker, and Taller Glenoid Labrum Morphology at 12 O’Clock Position in Healthy Young Adults
Description:
Purpose
To investigate location‐ and sex‐specific glenoid labrum morphology of healthy young adults in vivo, and the labrum's effects on depth and radius of curvature (ROC) of the glenohumeral joint.
Methods
Healthy young adults with no history of shoulder surgery, injury, or instability underwent computed tomography and magnetic resonance imaging scans.
Bone, cartilage, and labrum tissues were segmented from the scans and used to create 3‐dimensional models for each participant.
Measurements were made on the coregistered 3‐dimensional models.
The labral thickness, height, and depth were expressed according to a clockface on the glenoid (3, 6, 9, and 12 o'clock locations).
Glenoid depth and ROC were also measured.
Comparisons were made between sexes and among clockface locations.
Results
Sixty shoulders of 30 individuals (15 males/15 females, average age: 25 ± 7 years, body mass Index: 25.
4 kg/m
2
) were included.
Repeated segmentation of a subset of the data showed the average absolute differences in labrum depth ranged from 0.
3 to 0.
4 mm, the labrum thickness differences ranged from 0.
3 to 0.
8 mm, and the labrum height differences ranged from 0.
4 to 0.
8 mm between the original and resegmented scans.
For the complete dataset, no location‐specific differences in labrum morphology were found between males and females.
The 12 o'clock location was at least 5.
0 mm deeper, 4.
3 mm thicker, and 8.
4 mm taller than any other clockface location (all
P
< .
001).
The labrum increased the average depth of the glenoid between 2.
4 and 5.
6 mm in the anterior/posterior and superior/inferior locations, respectively (
P
< .
001), contributing an average of 60.
1% of the overall glenoid depth, and decreasing the average ROC by 22.
6 mm in the anterior/posterior locations and by 8.
8 mm in the superior/inferior locations.
Conclusions
The labrum in young healthy adults was found to be larger than previously reported in cadaver studies.
The labrum at 12 o'clock is deeper, thicker, and taller than at other locations; however, no location‐specific differences were found between men and women.
The labrum contributed significantly to the depth and created a more congruent joint by minimizing differences between humerus and glenoid ROC.
Clinical Relevance
Improved understanding of the morphology of the glenoid labrum in young adults may be used to guide surgical repair and design of anatomical shoulder replacements.
Related Results
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract
Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
Immunohistochemical analysis of mechanoreceptors in transverse acetabular ligament and labrum: a prospective analysis of 35 cases
Immunohistochemical analysis of mechanoreceptors in transverse acetabular ligament and labrum: a prospective analysis of 35 cases
Abstract
Objective: The labrum and transverse acetabular ligament (TAL) are classically described as distinct anatomical structures with abundant mechanoreceptors and free nerve f...
Morphometric analysis of cavitas glenoidalis with multidedector CT
Morphometric analysis of cavitas glenoidalis with multidedector CT
The glenoid cavity is a sliced egg-shaped joint surface located on the lateral margin of the scapula to form the shoulder joint. Recognition of variations in shape and dimensions o...
Comparison of Labrum Resistance Force while Pull-Probing In Vivo and Cadaveric Hips
Comparison of Labrum Resistance Force while Pull-Probing In Vivo and Cadaveric Hips
Cadaver tissue has been identified as the highest-fidelity anatomical representation in terms of the training for orthopedic surgery, including for arthroscopy of a damaged hip lab...
Sensitivity of Preoperative Magnetic Resonance Imaging and Magnetic Resonance Arthrography in Detection of Panlabral Tears of the Glenohumeral Joint
Sensitivity of Preoperative Magnetic Resonance Imaging and Magnetic Resonance Arthrography in Detection of Panlabral Tears of the Glenohumeral Joint
Purpose
The purpose of this study was to evaluate the sensitivity of preoperative magnetic resonance imaging (MRI) in detecting combined lesions of the glenoid ...
JP4.1 The resistance during hip labrum probing correlates with its mechanical property.
JP4.1 The resistance during hip labrum probing correlates with its mechanical property.
Abstract
Background
In hip arthroscopic surgery, probing the acetabular labrum with an arthroscopic probe prior to treatm...
Morphometric analysis of glenoid cavity in adult human scapulae and its clinical importance
Morphometric analysis of glenoid cavity in adult human scapulae and its clinical importance
Background: The glenoid cavity of scapula is quite small, which allows space for only limited fixation devices. Appropriate fixation of the glenoid component of shoulder is of key ...

