Application of Time/Temperature Fire Curves for the Estimation of Fire Resistance of Transformer within Protective Structures

View through CrossRef
At each power facility, a number of key elements can be identified thanks to which the power industry functions. One of these elements is transformers, which contain oil in their constructions. Being influenced by such factors as high oil temperature during operation of the device and actual flammability of this dielectric they become hazardous. Fires involving transformers are considered crucial due to the large amount of oil in contact with high-voltage elements. Therefore, it is advisable to prevent fires involving transformers. This condition can be met by maintaining the power equipment of transformer stations in good condition and without overheating. At the same time, transformers are currently a priority target for remote bombing due to Russian aggression against Ukraine. The high failure rate and the corresponding consequences for transformer reliability and safety require in-depth assessment. The paper briefly describes possible preventive measures that are currently being implemented in Ukraine to avoid incidents related to fires involving transformers. The application of standardized time/temperature fire curves is considered when assessing the fire resistance classes of protective structures in which transformers are located in today’s conditions. Based on the results of the scientific research, the current state of the art in determining the temperature effect of fire when assessing the fire resistance class of enclosing protective structures within which transformers are located has been analyzed. The purpose of further research, scientific tasks, object and subject of the research and further areas of work are formulated. Scientific research was conducted using analytical methods, in particular analysis and generalization of previously performed works. As the research tools, statistical data on fires, current requirements of regulatory documents, scientific achievements on the researched issue derived by other scientists, and statistical method for processing research results were used.
Title: Application of Time/Temperature Fire Curves for the Estimation of Fire Resistance of Transformer within Protective Structures
Description:
At each power facility, a number of key elements can be identified thanks to which the power industry functions.
One of these elements is transformers, which contain oil in their constructions.
Being influenced by such factors as high oil temperature during operation of the device and actual flammability of this dielectric they become hazardous.
Fires involving transformers are considered crucial due to the large amount of oil in contact with high-voltage elements.
Therefore, it is advisable to prevent fires involving transformers.
This condition can be met by maintaining the power equipment of transformer stations in good condition and without overheating.
At the same time, transformers are currently a priority target for remote bombing due to Russian aggression against Ukraine.
The high failure rate and the corresponding consequences for transformer reliability and safety require in-depth assessment.
The paper briefly describes possible preventive measures that are currently being implemented in Ukraine to avoid incidents related to fires involving transformers.
The application of standardized time/temperature fire curves is considered when assessing the fire resistance classes of protective structures in which transformers are located in today’s conditions.
Based on the results of the scientific research, the current state of the art in determining the temperature effect of fire when assessing the fire resistance class of enclosing protective structures within which transformers are located has been analyzed.
The purpose of further research, scientific tasks, object and subject of the research and further areas of work are formulated.
Scientific research was conducted using analytical methods, in particular analysis and generalization of previously performed works.
As the research tools, statistical data on fires, current requirements of regulatory documents, scientific achievements on the researched issue derived by other scientists, and statistical method for processing research results were used.

Related Results

Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
High frequency modeling of power transformers under transients
High frequency modeling of power transformers under transients
This thesis presents the results related to high frequency modeling of power transformers. First, a 25kVA distribution transformer under lightning surges is tested in the laborator...
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract Introduction Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...
PLC Based Load Sharing of Transformers
PLC Based Load Sharing of Transformers
The transformer is very expensive and bulky power system equipment. It runs and feed the load for 24 hours a day. Sometimes the load on the transformer unexpectedly rises above its...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Type Curves For McKinley Analysis Of Drill-Stem Test Data
Type Curves For McKinley Analysis Of Drill-Stem Test Data
Abstract McKinley-type curves that include the effects of short production times (i.e., less than 120 minutes) have been developed for pressure buildup test analy...

Back to Top