Javascript must be enabled to continue!
Verification Of the Analysis Method For Determining Cetirizine HCl Levels in Cetirizine Syrup Preparations By High-Performance Liquid Chromatography According To The Compendial Method Of The Indonesian Pharmacopoeia, VIth Edition, 2020
View through CrossRef
Cetirizine Hydrochloride is a second-generation antihistamine that is effective for allergy therapy and is widely used in syrup dosage forms. The quality of drug preparations requires a valid assay analysis method to ensure the active substance content meets the requirements. This study aims to verify the analysis method for determining the content of Cetirizine Hydrochloride in syrup preparations using High Performance Liquid Chromatography (HPLC) in accordance with the Indonesian Pharmacopoeia Edition VI 2020 standards. The study was conducted at the Quality Control Laboratory of PT. X using an HPLC system equipped with an L10 column and UV detector set at 233 nm. Method verification parameters include system suitability testing, specificity, accuracy, precision, as well as linearity and range in determining the content of Cetirizine Hydrochloride. The results demonstrated that all verification parameters met the acceptance criteria. The system suitability test gave good results with an area RSD value of 0.232% and a tailing factor of 1.389. The method was proven to be specific with a retention time of 24.842 minutes without interference from the matrix. The accuracy of the assay method was confirmed with an average recovery value of 101.06% in the concentration range of 80–120% of the nominal concentration, and excellent precision with an RSD value of 0.31%. Linearity and range tests showed an excellent linear relationship in the concentration range of 80–120% with a correlation coefficient (r) of 0.9996. Based on these results, the analysis method for determining the content of Cetirizine Hydrochloride in syrup preparations was declared valid and suitable for use in routine quality control analysis.
CV. Afdifal Maju Berkah
Title: Verification Of the Analysis Method For Determining Cetirizine HCl Levels in Cetirizine Syrup Preparations By High-Performance Liquid Chromatography According To The Compendial Method Of The Indonesian Pharmacopoeia, VIth Edition, 2020
Description:
Cetirizine Hydrochloride is a second-generation antihistamine that is effective for allergy therapy and is widely used in syrup dosage forms.
The quality of drug preparations requires a valid assay analysis method to ensure the active substance content meets the requirements.
This study aims to verify the analysis method for determining the content of Cetirizine Hydrochloride in syrup preparations using High Performance Liquid Chromatography (HPLC) in accordance with the Indonesian Pharmacopoeia Edition VI 2020 standards.
The study was conducted at the Quality Control Laboratory of PT.
X using an HPLC system equipped with an L10 column and UV detector set at 233 nm.
Method verification parameters include system suitability testing, specificity, accuracy, precision, as well as linearity and range in determining the content of Cetirizine Hydrochloride.
The results demonstrated that all verification parameters met the acceptance criteria.
The system suitability test gave good results with an area RSD value of 0.
232% and a tailing factor of 1.
389.
The method was proven to be specific with a retention time of 24.
842 minutes without interference from the matrix.
The accuracy of the assay method was confirmed with an average recovery value of 101.
06% in the concentration range of 80–120% of the nominal concentration, and excellent precision with an RSD value of 0.
31%.
Linearity and range tests showed an excellent linear relationship in the concentration range of 80–120% with a correlation coefficient (r) of 0.
9996.
Based on these results, the analysis method for determining the content of Cetirizine Hydrochloride in syrup preparations was declared valid and suitable for use in routine quality control analysis.
Related Results
Marketing research of the market power of cetirizine antihistamines
Marketing research of the market power of cetirizine antihistamines
Aim. To study and assess the components of the trademark complex, as well as to determine the market power of anti-allergic drugs on the example of Cetirizine.
Materials and metho...
Alteration of Serum Liver Enzymes Level Caused by Cetirizine Hydrochloride in Exercise Performers
Alteration of Serum Liver Enzymes Level Caused by Cetirizine Hydrochloride in Exercise Performers
Background: Players regularly use cetirizine HCL for the prevention and treatment of various symptoms of allergy while playing in unfamiliar environments.
Objective: This ...
Chlorine photochemistry in the Mars Planetary Climate Model 
Chlorine photochemistry in the Mars Planetary Climate Model 
Introduction A few years ago, two instruments on the Mars Trace Gas Orbiter (TGO) revealed the presence of hydrogen chloride (HCl) at ppbv levels in the Martian atmosphere during M...
Expression of ROR1 and ROR2 in Hairy Cell Leukemia Cells Enhances Constitutive Activation of ERK1/2 and Cancer Stemness
Expression of ROR1 and ROR2 in Hairy Cell Leukemia Cells Enhances Constitutive Activation of ERK1/2 and Cancer Stemness
Hairy cell leukemia (HCL) is a malignancy of B-cells that co-express CD19, CD20, CD11c, CD25, CD103, CD123, and CD200 (but not CD5, CD10, CD21, or CD23) and that harbor a V600E BRA...
Effectiveness of Postburn Pruritus Treatment and Improvement of Insomnia—A Randomized Trial
Effectiveness of Postburn Pruritus Treatment and Improvement of Insomnia—A Randomized Trial
Abstract
Postburn pruritus is difficult to assess and treat. Antihistamines used in its treatment provide little relief. Identification of the itch neuronal pathway ...
Verification of High Speed on Chip with VIP using System Verilog
Verification of High Speed on Chip with VIP using System Verilog
Abstract - The exploration work is addressing verification of High speed on chips protocol; we've used the system Verilog grounded test bench structure. I developed a system Verilo...
A Clinical Training Program for Hybrid Closed-Loop Therapy in a Pediatric Diabetes Clinic
A Clinical Training Program for Hybrid Closed-Loop Therapy in a Pediatric Diabetes Clinic
Background: The first hybrid closed loop (HCL) system became commercially available in the U.S. in 2017, and there is no standard process for training patients. The goal of this qu...

