Radiopacity of Composite Luting Cements Using a Digital Technique

View through CrossRef
AbstractPurposeThe aim of this in vitro study was to evaluate the radiopacity of 20 common dental composite luting materials using a digital technique.Materials and MethodsA 1‐mm‐thick specimen of each material with a human tooth slice and aluminium step wedge were tested using digital radiographs under four combinations of exposure and voltage. The radiopacity in pixels was determined using computer software. The equivalent thickness of aluminium for each material was then calculated based on the calibration curve.ResultsAll tested materials except one had higher radiopacity than dentin (p > α; α  =  0.01), and 80% of the materials had radiopacity above enamel value (p > α; α  =  0.01). Moreover, 40% of tested materials had radiopacity of three times above the minimal International Organization for Standardization (ISO) values for composite luting cements. At all exposure values, the highest radiopacity was for Solocem and Multilink groups of materials, at three to six times above dentin radiopacity. Only Variolink Veneer showed radiopacity below dentin and enamel.ConclusionsComposite luting materials should have radiopacity above ISO values or greater than the dentin or enamel equivalent. The highest radiopacity values were for the Solocem and Multilink family composite luting cements. Clinicians should choose materials with high radiopacity values, and manufacturers should be aware of the radiopacity values when introducing materials on the market.
Title: Radiopacity of Composite Luting Cements Using a Digital Technique
Description:
AbstractPurposeThe aim of this in vitro study was to evaluate the radiopacity of 20 common dental composite luting materials using a digital technique.
Materials and MethodsA 1‐mm‐thick specimen of each material with a human tooth slice and aluminium step wedge were tested using digital radiographs under four combinations of exposure and voltage.
The radiopacity in pixels was determined using computer software.
The equivalent thickness of aluminium for each material was then calculated based on the calibration curve.
ResultsAll tested materials except one had higher radiopacity than dentin (p > α; α  =  0.
01), and 80% of the materials had radiopacity above enamel value (p > α; α  =  0.
01).
Moreover, 40% of tested materials had radiopacity of three times above the minimal International Organization for Standardization (ISO) values for composite luting cements.
At all exposure values, the highest radiopacity was for Solocem and Multilink groups of materials, at three to six times above dentin radiopacity.
Only Variolink Veneer showed radiopacity below dentin and enamel.
ConclusionsComposite luting materials should have radiopacity above ISO values or greater than the dentin or enamel equivalent.
The highest radiopacity values were for the Solocem and Multilink family composite luting cements.
Clinicians should choose materials with high radiopacity values, and manufacturers should be aware of the radiopacity values when introducing materials on the market.

Related Results

ELECTRICAL RESISTANCE OF DENTAL LUTING CEMENTS INVESTIGATED BY IMPEDANCE METHODOLOGY RELATED TO THEIR POROSITIES AND SOLUBILITY
ELECTRICAL RESISTANCE OF DENTAL LUTING CEMENTS INVESTIGATED BY IMPEDANCE METHODOLOGY RELATED TO THEIR POROSITIES AND SOLUBILITY
The electrical resistance property of dental cement is one of important physical properties. Most previous studies aimed to investigate the mechanical properties, solubility and es...
Radiopacity of calcium hydroxide cement compared with human tooth structure
Radiopacity of calcium hydroxide cement compared with human tooth structure
AIMS: All materials added to teeth should present an adequate radiopacity to allow the detection of secondary caries. Usually, in extensive cavities, base materials like calcium hy...
Novel phosphate-based cements for clinical applications
Novel phosphate-based cements for clinical applications
This Thesis aims at the development of two novel families of inorganic phosphate cements with suitable characteristics for clinical applications in hard tissue regeneration or repl...
A literature review on various luting cements used in dentistry
A literature review on various luting cements used in dentistry
The success rate of the given fixed partial denture and the longevity of the fixed partial denture is depend on the tooth preparation and the usage of the luting cement under the f...
Micromorphology of Porosity Related to Electrical Resistance of Dental Luting Cements
Micromorphology of Porosity Related to Electrical Resistance of Dental Luting Cements
The aim was to investigate the relation between micromorphology of porosity and electrical resistance of dental luting cements. Five dental luting cements were evaluated: zinc phos...
Dental Cements
Dental Cements
The manifold uses of dental cements-as (a) luting agents, (b) cavity linings and bases, and (c) restorations for teeth—make them perhaps the most important materials in clinical de...
Original Research Article Effect of Radiotherapy on Flexural Strength of Luting Cementsan In Vitro Study
Original Research Article Effect of Radiotherapy on Flexural Strength of Luting Cementsan In Vitro Study
Aim - The aim of this study was to evaluate changes in the flexural strength of luting cements due to radiotherapy. Methodology- Total of 90 rectangular specimens of 25×2×2 mm dime...

Back to Top