Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Noninvasive acoustic cell trapping in a microfluidic perfusion system for online bioassays

View through Europeana Collections
Techniques for manipulating, separating, and trapping particles and cells are highly desired in today's bioanalytical and biomedical field. The microfluidic chip-based acoustic noncontact trapping method earlier developed within the group now provides a flexible platform for performing cell- and particle-based assays in continuous flow microsystems. An acoustic standing wave is generated in etched glass channels (600x61 microm2) by miniature ultrasonic transducers (550x550x200 microm3). Particles or cells passing the transducer will be retained and levitated in the center of the channel without any contact with the channel walls. The maximum trapping force was calculated to be 430+/-135 pN by measuring the drag force exerted on a single particle levitated in the standing wave. The temperature increase in the channel was characterized by fluorescence measurements using rhodamine B, and levels of moderate temperature increase were noted. Neural stem cells were acoustically trapped and shown to be viable after 15 min. Further evidence of the mild cell handling conditions was demonstrated as yeast cells were successfully cultured for 6 h in the acoustic trap while being perfused by the cell medium at a flowrate of 1 microL/min. The acoustic microchip method facilitates trapping of single cells as well as larger cell clusters. The noncontact mode of cell handling is especially important when studies on nonadherent cells are performed, e.g., stem cells, yeast cells, or blood cells, as mechanical stress and surface interaction are minimized. The demonstrated acoustic trapping of cells and particles enables cell- or particle-based bioassays to be performed in a continuous flow format.
image-zoom
Title: Noninvasive acoustic cell trapping in a microfluidic perfusion system for online bioassays
Description:
Techniques for manipulating, separating, and trapping particles and cells are highly desired in today's bioanalytical and biomedical field.
The microfluidic chip-based acoustic noncontact trapping method earlier developed within the group now provides a flexible platform for performing cell- and particle-based assays in continuous flow microsystems.
An acoustic standing wave is generated in etched glass channels (600x61 microm2) by miniature ultrasonic transducers (550x550x200 microm3).
Particles or cells passing the transducer will be retained and levitated in the center of the channel without any contact with the channel walls.
The maximum trapping force was calculated to be 430+/-135 pN by measuring the drag force exerted on a single particle levitated in the standing wave.
The temperature increase in the channel was characterized by fluorescence measurements using rhodamine B, and levels of moderate temperature increase were noted.
Neural stem cells were acoustically trapped and shown to be viable after 15 min.
Further evidence of the mild cell handling conditions was demonstrated as yeast cells were successfully cultured for 6 h in the acoustic trap while being perfused by the cell medium at a flowrate of 1 microL/min.
The acoustic microchip method facilitates trapping of single cells as well as larger cell clusters.
The noncontact mode of cell handling is especially important when studies on nonadherent cells are performed, e.
g.
, stem cells, yeast cells, or blood cells, as mechanical stress and surface interaction are minimized.
The demonstrated acoustic trapping of cells and particles enables cell- or particle-based bioassays to be performed in a continuous flow format.

Related Results

MARS-seq2.0: an experimental and analytical pipeline for indexed sorting combined with single-cell RNA sequencing v1
MARS-seq2.0: an experimental and analytical pipeline for indexed sorting combined with single-cell RNA sequencing v1
Human tissues comprise trillions of cells that populate a complex space of molecular phenotypes and functions and that vary in abundance by 4–9 orders of magnitude. Relying solely ...
A Microfluidic Device for Hydrodynamic Trapping and Manipulation Platform of a Single Biological Cell
A Microfluidic Device for Hydrodynamic Trapping and Manipulation Platform of a Single Biological Cell
To perform specific analysis for the single cell, individual cells have to be captured and separated from each other before further treatments and analysis can be carried out. This...
Comparison of Stress-rest and Stress-LGE analysis strategy in patients undergoing stress perfusion cardiovascular magnetic resonance
Comparison of Stress-rest and Stress-LGE analysis strategy in patients undergoing stress perfusion cardiovascular magnetic resonance
ABSTRACTBACKGROUNDStress perfusion cardiovascular magnetic resonance (CMR) is increasingly used without rest perfusion for the quantification of ischemia burden. However, the optim...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Optical Fiber Tweezers: A Versatile Tool for Optical Trapping and Manipulation
Optical Fiber Tweezers: A Versatile Tool for Optical Trapping and Manipulation
Optical trapping is widely used in different areas, ranging from biomedical applications, to physics and material sciences. In recent years, optical fiber tweezers have attracted s...
Study on the characteristics of microcirculation in the site of pressure ulcer in patients with spinal cord injury
Study on the characteristics of microcirculation in the site of pressure ulcer in patients with spinal cord injury
To investigate the characteristics of pressure ulcer microcirculation in SCI patients with pressure ulcer, and to provide evidence for the treatment of pressure ulcer in patients w...
Early Assessment of Response to Radiofrequency Ablation With CT Perfusion Imaging in Rabbit VX2 Liver Tumor Model
Early Assessment of Response to Radiofrequency Ablation With CT Perfusion Imaging in Rabbit VX2 Liver Tumor Model
ObjectivesTo discriminate viable tumors from benign periablational enhancement (BPE) in early stage after radiofrequency ablation (RFA) is a major confounding problem. The goal of ...

Back to Top