Javascript must be enabled to continue!
TH‐C‐303A‐04: Evaluation of 3D Surface Camera System in Patient Setup for HN RT
View through CrossRef
Purpose: To evaluate the usefulness of a 3D surface camera system (AlignRT) in detecting rigid and non‐rigid setup errors during head and neck radiotherapy. Methods and Materials: To evaluate the accuracy of AlignRT's surface registration algorithm, both translational and rotational movements of a known magnitude were manually applied in Pinnacle to transform a helical CT scan. The skin contours of both the primary helical CT scan and the transformed helical CT scan were transferred to AlignRT, where the transformed surface was registered to the primary surface. The changes that were reported by the AlignRT system were compared to the manually applied motions from Pinnacle. To evaluate the usefulness of AlignRT for rigid and non‐rigid patient setup, a retrospective analysis was performed on the helical CT scans of eleven patients. The registrations in Pinnacle based on bony (either skull (rigid) or vertebrae (non‐rigid)) anatomy were compared to the surface (either head (rigid) or shoulder (non‐rigid)) registrations in AlignRT. Results: The accuracy of AlignRT's surface registration algorithm was, on average, 0.041 ± 0.036 degrees and 0.075 ± 0.100 mm. The accuracy of the optical system was, on average, 0.087 ± 0.912 degrees and −0.153 ± 1.996 mm. For shoulder (non‐rigid) guidance, if we use 2*standard deviation for 95% confidence level, the accuracy of the optical system was within 3 degrees for rotations in the vertical and longitudinal directions, but 5 degrees for the lateral direction. For translations, the accuracy was more than 10 mm.Conclusion: While the feasibility of using the AlignRT system for head (rigid) guidance in the setup of HN patients was demonstrated, the use of the system in non‐rigid patient setup yielded undesirable results.
Title: TH‐C‐303A‐04: Evaluation of 3D Surface Camera System in Patient Setup for HN RT
Description:
Purpose: To evaluate the usefulness of a 3D surface camera system (AlignRT) in detecting rigid and non‐rigid setup errors during head and neck radiotherapy.
Methods and Materials: To evaluate the accuracy of AlignRT's surface registration algorithm, both translational and rotational movements of a known magnitude were manually applied in Pinnacle to transform a helical CT scan.
The skin contours of both the primary helical CT scan and the transformed helical CT scan were transferred to AlignRT, where the transformed surface was registered to the primary surface.
The changes that were reported by the AlignRT system were compared to the manually applied motions from Pinnacle.
To evaluate the usefulness of AlignRT for rigid and non‐rigid patient setup, a retrospective analysis was performed on the helical CT scans of eleven patients.
The registrations in Pinnacle based on bony (either skull (rigid) or vertebrae (non‐rigid)) anatomy were compared to the surface (either head (rigid) or shoulder (non‐rigid)) registrations in AlignRT.
Results: The accuracy of AlignRT's surface registration algorithm was, on average, 0.
041 ± 0.
036 degrees and 0.
075 ± 0.
100 mm.
The accuracy of the optical system was, on average, 0.
087 ± 0.
912 degrees and −0.
153 ± 1.
996 mm.
For shoulder (non‐rigid) guidance, if we use 2*standard deviation for 95% confidence level, the accuracy of the optical system was within 3 degrees for rotations in the vertical and longitudinal directions, but 5 degrees for the lateral direction.
For translations, the accuracy was more than 10 mm.
Conclusion: While the feasibility of using the AlignRT system for head (rigid) guidance in the setup of HN patients was demonstrated, the use of the system in non‐rigid patient setup yielded undesirable results.
Related Results
Autonomy on Trial
Autonomy on Trial
Photo by CHUTTERSNAP on Unsplash
Abstract
This paper critically examines how US bioethics and health law conceptualize patient autonomy, contrasting the rights-based, individualist...
Machine learning techniques for forensic camera model identification and anti-forensic attacks
Machine learning techniques for forensic camera model identification and anti-forensic attacks
The goal of camera model identification is to determine the manufacturer and model of an image's source camera. Camera model identification is an important task in multimedia foren...
Improving Setup Precision in DIBH Radiotherapy for Left-Sided Breast Cancer: Tattoo-less vs. Tattoo-Based Surface-Guided and Respiratory Gating Techniques
Improving Setup Precision in DIBH Radiotherapy for Left-Sided Breast Cancer: Tattoo-less vs. Tattoo-Based Surface-Guided and Respiratory Gating Techniques
Introduction: Deep inspiration breath-hold (DIBH) is a widely used technique to minimize radiation exposure to the heart during radiotherapy for left-sided breast cancer. Several c...
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract
The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...
Application of hybrid analytic hierarchy process and graph theoretic approach for analysis of barriers of high setup time
Application of hybrid analytic hierarchy process and graph theoretic approach for analysis of barriers of high setup time
PurposeIn the era of the circular economy, the economic growth of a country is highly dependent on the sustainable performance of the manufacturing sector. In today’s increasingly ...
Pose estimation with event camera
Pose estimation with event camera
Estimation de la pose avec une caméra évènementielle
La pose de la caméra est utilisée pour décrire la position et l'orientation d'une caméra dans un système de coo...
TEKNOLOGI MOTION-BASED TRACKING UNTUK PENGEMBANGAN APLIKASI KEAMANAN
TEKNOLOGI MOTION-BASED TRACKING UNTUK PENGEMBANGAN APLIKASI KEAMANAN
The surveillance camera system is widely used by the public. The surveillance camera system used is usually a CCTV camera. In general, CCTV cameras can only record video. Se...
Evaluation of a Voice-Enabled Autonomous Camera Control System for the da Vinci Surgical Robot
Evaluation of a Voice-Enabled Autonomous Camera Control System for the da Vinci Surgical Robot
Robotic surgery involves significant task switching between tool control and camera control, which can be a source of distraction and error. This study evaluated the performance of...