On using polarization filters to build a high performance polarimeter/spectrometer

View through CrossRef
Polarization is a topic largely neglected in spectroscopic investigation of planetary science. While true the degree of polarization is small in many observational situations, one can show that it has incur some bias in recent retrieval studies. Looking towards the future, with more high-performance spectrometers being sent to other planets, we would argue that future spectrometers should consider addressing polarization early in their design.Polarization of light commonly occurs dues to scattering by surfaces, aerosols (e.g. clouds), and molecules. The different polarization states of light entering the spectrometer instrument can have different transmission efficiencies to arrive at the detector, leading to a polarization sensitivity of the instrument. The combination of these two mechanisms leads to an incorrect calibration of radiances used for science retrievals. Especially when the target absorption features and the polarization features are correlated/anticorrelated, this leads to an unknown error in the retrieval. One can adapt their end-to-end tool to characterize this error and include it in the total error budget.One can include other elements in their design to correct for, or measure, the polarization. The simplest method might be to include a polarization scrambler early in the optical path. This would nullify the polarization sensitivity of the instrument. Then the retrieval tool can ignore polarization in the forward model completely. Still, in some cases, the forward model including or not including polarization can lead to large difference in the total radiance entering the instrument due to missing terms in scattering. Therefore, including a scrambler can still lead to some retrieval error. We present some estimations of this bias from recent Mars missions.Alternatively, one can use a combination of polarized filters and perform simultaneous (or near simultaneous) observations of the reflected radiance. By combining these spectra and using the knowledge of (and some assumptions based on) the observation geometry, one can determine the total radiance and some elements of the polarization state. We will present different options for filter combinations and discuss their calibration accuracy and performance. We present some design options for a spectrometer going to Venus, with the trade offs that need to be considered. As a bonus, the polarization state is a result of properties of the scattering medium. So, for instance, it can be used to constrain the aerosol size and composition.
Title: On using polarization filters to build a high performance polarimeter/spectrometer
Description:
Polarization is a topic largely neglected in spectroscopic investigation of planetary science.
While true the degree of polarization is small in many observational situations, one can show that it has incur some bias in recent retrieval studies.
Looking towards the future, with more high-performance spectrometers being sent to other planets, we would argue that future spectrometers should consider addressing polarization early in their design.
Polarization of light commonly occurs dues to scattering by surfaces, aerosols (e.
g.
clouds), and molecules.
The different polarization states of light entering the spectrometer instrument can have different transmission efficiencies to arrive at the detector, leading to a polarization sensitivity of the instrument.
The combination of these two mechanisms leads to an incorrect calibration of radiances used for science retrievals.
Especially when the target absorption features and the polarization features are correlated/anticorrelated, this leads to an unknown error in the retrieval.
One can adapt their end-to-end tool to characterize this error and include it in the total error budget.
One can include other elements in their design to correct for, or measure, the polarization.
The simplest method might be to include a polarization scrambler early in the optical path.
This would nullify the polarization sensitivity of the instrument.
Then the retrieval tool can ignore polarization in the forward model completely.
Still, in some cases, the forward model including or not including polarization can lead to large difference in the total radiance entering the instrument due to missing terms in scattering.
Therefore, including a scrambler can still lead to some retrieval error.
We present some estimations of this bias from recent Mars missions.
Alternatively, one can use a combination of polarized filters and perform simultaneous (or near simultaneous) observations of the reflected radiance.
By combining these spectra and using the knowledge of (and some assumptions based on) the observation geometry, one can determine the total radiance and some elements of the polarization state.
We will present different options for filter combinations and discuss their calibration accuracy and performance.
We present some design options for a spectrometer going to Venus, with the trade offs that need to be considered.
As a bonus, the polarization state is a result of properties of the scattering medium.
So, for instance, it can be used to constrain the aerosol size and composition.

Related Results

Influence of polarization on irradiating LiF crystal by femtosecond laser
Influence of polarization on irradiating LiF crystal by femtosecond laser
The processing morphology of cubic crystal LiF irradiated by femtosecond laser varies with the polarization direction. When the polarization direction is parallel to the crystal or...
Small phase angle polarization properties of regolith-like materials - the "Mixing Effect"
Small phase angle polarization properties of regolith-like materials - the "Mixing Effect"
<p>Polarization phase curves of asteroids and other small airless bodies are influenced by the compositional and physical properties of their regolith. The mixing of ...
Filtration, 2. Equipment
Filtration, 2. Equipment
Abstract The article contains sections titled: ...
Complex discrete comb filters with individually tunable partial domains
Complex discrete comb filters with individually tunable partial domains
Problem Statement. The design of tunable complex discrete non-recursive and recursive bandpass and bandstop comb filters is currently a highly relevant task for solving problems of...
Novel transversal topologies and coupled resonator configurations for acoustic wave filters
Novel transversal topologies and coupled resonator configurations for acoustic wave filters
(English) During the last years, electro-acoustic technology has been a key factor in the development of portable devices thanks to its high performance and very compact filtering ...
Comparison of linear and circular polarization in foggy environments at UV-NIR wavelengths
Comparison of linear and circular polarization in foggy environments at UV-NIR wavelengths
This paper investigates the polarization persistence of linear polarization and circular polarization in foggy environments from ultraviolet (UV) to near-infrared (NIR). Using pola...
Methods for the collection and characterization of airborne particles in the textile industry
Methods for the collection and characterization of airborne particles in the textile industry
Airborne particulate matter is one of the main air pollutants. Their impact on mortality, and the occurrence of pulmonary and cardiovascular ...
Study on multi-beam superposition using complementary polarization control plates
Study on multi-beam superposition using complementary polarization control plates
In order to meet the requirement for uniform irradiation on the target in inertial confinement fusion, a schemie is proposed for achieving the depolarized superposition of multi-be...

Back to Top