Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Investigation of Plastic Hinge Length in Reinforced Concrete Columns on Column Behavior

View through CrossRef
In reinforced concrete buildings in case of a possible earthquake, the buildings slamp as they lost their horizontal stability because of hinging of column ends. The assumptions for plastic hinge lengths are present during project stage of reinforced concrete buildings. According to Turkish Earthquake Regulations, although plastic hinge length is determined to be 0.5h, it's known that plastic hinge length is determined via various formulas in some other regulations all over the world. In reinforced concrete columns, it's necessary to indicate the effect of plastic hinge length on the column behavior. For this purpose, pushover analysis of 5 column samples having different plastic hinge lengths was performed with non-linear analysis program. As a result of pushover analysis, situations of plastic hinges formed in columns and their load-displacement curves were determined. The graphs and the data were compared and the results were discussed.
Title: Investigation of Plastic Hinge Length in Reinforced Concrete Columns on Column Behavior
Description:
In reinforced concrete buildings in case of a possible earthquake, the buildings slamp as they lost their horizontal stability because of hinging of column ends.
The assumptions for plastic hinge lengths are present during project stage of reinforced concrete buildings.
According to Turkish Earthquake Regulations, although plastic hinge length is determined to be 0.
5h, it's known that plastic hinge length is determined via various formulas in some other regulations all over the world.
In reinforced concrete columns, it's necessary to indicate the effect of plastic hinge length on the column behavior.
For this purpose, pushover analysis of 5 column samples having different plastic hinge lengths was performed with non-linear analysis program.
As a result of pushover analysis, situations of plastic hinges formed in columns and their load-displacement curves were determined.
The graphs and the data were compared and the results were discussed.

Related Results

Strength analysis of concrete-encased cellular steel columns
Strength analysis of concrete-encased cellular steel columns
This research investigates the compression behavior of bare cellular steel columns and concrete-encased cellular steel (CECS) columns subjected to concentric and eccentric loadings...
Experimental research on compressive strength of UHPC spherical hinge
Experimental research on compressive strength of UHPC spherical hinge
Purpose In order to reduce the impact of bridge construction on traffic under the bridge, the construction of bridges for some important traffic nodes usually adopts the swivel con...
The Plastic Hinge Length Prediction of RC Members by Using ANN
The Plastic Hinge Length Prediction of RC Members by Using ANN
Abstract For many years, plastic hinges have been a very interesting and complex topic for researchers and engineers due to plastic deformations. Nonetheless, both standard...
Enhancing structural behaviour of polypropylene fibre concrete columns longitudinally reinforced with fibreglass bars
Enhancing structural behaviour of polypropylene fibre concrete columns longitudinally reinforced with fibreglass bars
Abstract The research aims to study the behaviour of concrete columns reinforced with fibreglass as bars exposed to seawater. Firstly, hardened concrete properties a...
The Effect of Some Parameters on Behaviour and Bearing Capacity of Multi-Drum Stone Columns under Static Load and Earthquake
The Effect of Some Parameters on Behaviour and Bearing Capacity of Multi-Drum Stone Columns under Static Load and Earthquake
In this thesis, the effect of several important parameters on the behaviour and bearing capacity of multi-drum stone columns loaded by short-term static loads and earthquakes was i...
He found use for reinforced concrete where, it would seem, this material has no place
He found use for reinforced concrete where, it would seem, this material has no place
Introduction. The article is devoted to an employee of the Research Institute of Reinforced Concrete, Doctor of Technical Sciences, Professor I.G. Ludkovsky, a specialist in the fi...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Lectin C gene analysis v1
Lectin C gene analysis v1
Mammalian Tissue Total RNA Purification Protocol by GeneJET RNA Purification Kit (Thermo Scientific, USA) Before starting: • Supplement the required amount of Lysis Buffer with β-...

Back to Top