Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Impact of cardiac output and alveolar ventilation in estimating ventilation/perfusion mismatch in ARDS using electrical impedance tomography

View through CrossRef
Abstract Introduction Electrical impedance tomography (EIT) can be used to assess ventilation/perfusion (V/Q) mismatch within the lungs. Several methods have been proposed, some of them neglecting the absolute value of alveolar ventilation (VA) and cardiac output (QC). Whether this omission results in acceptable bias is unknown. Methods Pixel-level V/Q maps of 25 ARDS patients were computed once considering (absolute V/Q map) and once neglecting (relative V/Q map) the value of QC and VA. Previously published indices of V/Q mismatch were computed using absolute V/Q maps and relative V/Q maps. Indices computed with relative V/Q maps were compared to their counterparts computed using absolute V/Q maps. Results Among 21 patients with ratio of alveolar ventilation to cardiac output (VA/QC) > 1, relative shunt fraction was significantly higher than absolute shunt fraction [37% (24–66) vs 19% (11–46), respectively, p < 0.001], while relative dead space fraction was significantly lower than absolute dead space fraction [40% (22–49) vs 58% (46–84), respectively, p < 0.001]. Relative wasted ventilation was significantly lower than the absolute wasted ventilation [16% (11–27) vs 29% (19–35), respectively, p < 0.001], while relative wasted perfusion was significantly higher than absolute wasted perfusion [18% (11–23) vs 11% (7–19), respectively, p < 0.001]. The opposite findings were retrieved in the four patients with VA/QC < 1. Conclusion Neglecting cardiac output and alveolar ventilation when assessing V/Q mismatch indices using EIT in ARDS patients results in significant bias, whose direction depends on the VA/QC ratio value.
Title: Impact of cardiac output and alveolar ventilation in estimating ventilation/perfusion mismatch in ARDS using electrical impedance tomography
Description:
Abstract Introduction Electrical impedance tomography (EIT) can be used to assess ventilation/perfusion (V/Q) mismatch within the lungs.
Several methods have been proposed, some of them neglecting the absolute value of alveolar ventilation (VA) and cardiac output (QC).
Whether this omission results in acceptable bias is unknown.
Methods Pixel-level V/Q maps of 25 ARDS patients were computed once considering (absolute V/Q map) and once neglecting (relative V/Q map) the value of QC and VA.
Previously published indices of V/Q mismatch were computed using absolute V/Q maps and relative V/Q maps.
Indices computed with relative V/Q maps were compared to their counterparts computed using absolute V/Q maps.
Results Among 21 patients with ratio of alveolar ventilation to cardiac output (VA/QC) > 1, relative shunt fraction was significantly higher than absolute shunt fraction [37% (24–66) vs 19% (11–46), respectively, p < 0.
001], while relative dead space fraction was significantly lower than absolute dead space fraction [40% (22–49) vs 58% (46–84), respectively, p < 0.
001].
Relative wasted ventilation was significantly lower than the absolute wasted ventilation [16% (11–27) vs 29% (19–35), respectively, p < 0.
001], while relative wasted perfusion was significantly higher than absolute wasted perfusion [18% (11–23) vs 11% (7–19), respectively, p < 0.
001].
The opposite findings were retrieved in the four patients with VA/QC < 1.
Conclusion Neglecting cardiac output and alveolar ventilation when assessing V/Q mismatch indices using EIT in ARDS patients results in significant bias, whose direction depends on the VA/QC ratio value.

Related Results

EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Characterizing a focused landscape of familial acute respiratory distress syndrome
Characterizing a focused landscape of familial acute respiratory distress syndrome
Abstract Background Acute respiratory distress syndrome (ARDS) affects approximately 190,600 patients per year in the United States, with mortality up to 45%. ARDS can occu...
Accuracy of the Radiographic Assessment of Lung Edema Score for the Diagnosis of ARDS
Accuracy of the Radiographic Assessment of Lung Edema Score for the Diagnosis of ARDS
Background: Bilateral opacities on chest radiographs are part of the Berlin Definition for Acute Respiratory Distress Syndrome (ARDS) but have poor interobserver reliability. The “...
ESM-1 Levels and ARDS Prediction Score for Predicting ARDS Occurrence in Sepsis Patients
ESM-1 Levels and ARDS Prediction Score for Predicting ARDS Occurrence in Sepsis Patients
Abstract Background: Acute respiratory distress syndrome (ARDS) development is overtly associated with elevated mortality. This study aimed to determine the parameters pred...
Rapidly improving acute respiratory distress syndrome in COVID-19: a multi-centre observational study
Rapidly improving acute respiratory distress syndrome in COVID-19: a multi-centre observational study
AbstractBackgroundBefore the pandemic of coronavirus disease (COVID-19), rapidly improving acute respiratory distress syndrome (ARDS), mostly defined by early extubation, had been ...
What Is Different in Acute Hematologic Malignancy-Associated ARDS? An Overview of the Literature
What Is Different in Acute Hematologic Malignancy-Associated ARDS? An Overview of the Literature
Background and Objectives: Acute hematologic malignancies are a group of heterogeneous blood diseases with a high mortality rate, mostly due to acute respiratory failure (ARF). Acu...
Prone Positioning in Spontaneously Breathing Subjects With Moderate or Severe ARDS During Invasive Ventilation
Prone Positioning in Spontaneously Breathing Subjects With Moderate or Severe ARDS During Invasive Ventilation
BACKGROUND: Prone positioning (PP) during invasive mechanical ventilation improves outcomes of patients with severe ARDS. Recent studies suggest that PP in spon...

Back to Top