Javascript must be enabled to continue!
Treatment of Industrial Textile Wastewater Using Polyarcrylamide (PAM) and Polyaluminium Chloride (PAC)
View through CrossRef
Dalam kajian ini, poliacrylamid (PAM) dan polialuminium klorida (PAC) telah digunakan sebagai bahan pengental untuk merawat air sisa industri tekstil. Eksperimen ini telah dijalankan dengan menggunakan ujian balang. Kesan dos, kelajuan percampuran dan masa pemendapan ke atas keberkesanan proses flokulasi telah dikaji. Air sisa yang terawat dianalisis untuk penyingkiran warna, pengurangan COD dan pengurangan kekeruhan. Keputusan yang diperolehi menunjukkan bahawa PAM adalah lebih baik daripada PAC dalam merawat air sisa tekstil. PAM mencatatkan penurunan parameter tertinggi, iaitu 6 NTU untuk kekeruhan, 744 mg / l untuk COD, dan scala kurang daripada 0.5 untuk warna. Prestasi tebaik PAM dicapai pada dos 0.07 g dan apabila proses flokulasi dijalankan pada 200 rpm kelajuan percampuran
dan 30 min masa pemendapan. Kajian ini juga mendapati bahawa parameter operasi yang dikaji (iaitu dos, kelajuan percampuran dan masa pemendapan) tidak banyak mempengaruhi ke atas penyingkiran warna, dan penurunan kekeruhan dan COD apabila PAC digunakan sebagai bahan pengental.
Kata kunci: Pengelompokan; poliacrylamid (PAM); polialuminium klorida (PAC); air sisa tekstil
In this study, polyacrylamide (PAM) and polyaluminum chloride (PAC) was used as a flocculant to treat industrial textile wastewater. The experiment was conducted using a Jar test experiment. The effect of dosage, mixing speed and settling time on the performance of the fflocculation process was investigated.
The treated textile wastewater was analyzed by its color removal, turbidity and COD reductions. The results obtained showed that PAM performed better in treating the textile wastewater compared to PAC.PAM recorded the highest reduction of parameters, which are 6 NTU for turbidity, 744 mg/l for COD, and scale less than 0.5 for colour. The best performance of PAM was achieved at dosage 0.07 g and when the flocculation process was conducted at 200 rpm of mixing speed and 30 min of settling time. It was also found that the investigated operating parameters (i.e. dosage, mixing speed and settling time) did not influence much on removal of color and reduction of turbidity and COD when PAC was used as flocculant.
Keywords: Flocculation; polyacrylamide (PAM); polyaluminum chloride (PAC); textile wastewater
Title: Treatment of Industrial Textile Wastewater Using Polyarcrylamide (PAM) and Polyaluminium Chloride (PAC)
Description:
Dalam kajian ini, poliacrylamid (PAM) dan polialuminium klorida (PAC) telah digunakan sebagai bahan pengental untuk merawat air sisa industri tekstil.
Eksperimen ini telah dijalankan dengan menggunakan ujian balang.
Kesan dos, kelajuan percampuran dan masa pemendapan ke atas keberkesanan proses flokulasi telah dikaji.
Air sisa yang terawat dianalisis untuk penyingkiran warna, pengurangan COD dan pengurangan kekeruhan.
Keputusan yang diperolehi menunjukkan bahawa PAM adalah lebih baik daripada PAC dalam merawat air sisa tekstil.
PAM mencatatkan penurunan parameter tertinggi, iaitu 6 NTU untuk kekeruhan, 744 mg / l untuk COD, dan scala kurang daripada 0.
5 untuk warna.
Prestasi tebaik PAM dicapai pada dos 0.
07 g dan apabila proses flokulasi dijalankan pada 200 rpm kelajuan percampuran
dan 30 min masa pemendapan.
Kajian ini juga mendapati bahawa parameter operasi yang dikaji (iaitu dos, kelajuan percampuran dan masa pemendapan) tidak banyak mempengaruhi ke atas penyingkiran warna, dan penurunan kekeruhan dan COD apabila PAC digunakan sebagai bahan pengental.
Kata kunci: Pengelompokan; poliacrylamid (PAM); polialuminium klorida (PAC); air sisa tekstil
In this study, polyacrylamide (PAM) and polyaluminum chloride (PAC) was used as a flocculant to treat industrial textile wastewater.
The experiment was conducted using a Jar test experiment.
The effect of dosage, mixing speed and settling time on the performance of the fflocculation process was investigated.
The treated textile wastewater was analyzed by its color removal, turbidity and COD reductions.
The results obtained showed that PAM performed better in treating the textile wastewater compared to PAC.
PAM recorded the highest reduction of parameters, which are 6 NTU for turbidity, 744 mg/l for COD, and scale less than 0.
5 for colour.
The best performance of PAM was achieved at dosage 0.
07 g and when the flocculation process was conducted at 200 rpm of mixing speed and 30 min of settling time.
It was also found that the investigated operating parameters (i.
e.
dosage, mixing speed and settling time) did not influence much on removal of color and reduction of turbidity and COD when PAC was used as flocculant.
Keywords: Flocculation; polyacrylamide (PAM); polyaluminum chloride (PAC); textile wastewater.
Related Results
Abstract 5077: Proteomic profiling reveals chemopreventive targets in esophageal adenocarcinoma
Abstract 5077: Proteomic profiling reveals chemopreventive targets in esophageal adenocarcinoma
Abstract
Esophageal adenocarcinoma (EAC) is characterized by rising incidence rates and high mortality due to late stage diagnosis and a lack of efficacious options ...
Polyaluminum Chlorides
Polyaluminum Chlorides
AbstractAluminum chloride hydroxide, AlCl(OH)2, AlCl2(OH), products, commonly known as polyaluminum chlorides (PAC), are used for a wide variety of industrial applications. Other n...
Performance Evaluation of PAM-4 and PAM-2 Modulation Techniques using MATLAB
Performance Evaluation of PAM-4 and PAM-2 Modulation Techniques using MATLAB
Two Levels Pulse Amplitude Modulation techniques (PAM-2) is failing to cope with the increase in appetite for data and higher data rate with respect to noisy channel. Hence, Four L...
Performance Evaluation of PAM-4 and PAM-2 Modulation Techniques using MATLAB
Performance Evaluation of PAM-4 and PAM-2 Modulation Techniques using MATLAB
Two Levels Pulse Amplitude Modulation techniques (PAM-2) is failing to cope with the increase in appetite for data and higher data rate with respect to noisy channel. Hence, Four L...
Molecular and biochemical characterization of novel PAM-like MBL variants, PAM-2 and PAM-3, from clinical isolates of Pseudomonas tohonis
Molecular and biochemical characterization of novel PAM-like MBL variants, PAM-2 and PAM-3, from clinical isolates of Pseudomonas tohonis
Abstract
Background
There is no comprehensive study on PAM-like MBLs.
Objectiv...
Uso de poliacrilamida como estrategia de control de erosión en un suelo altamente erodado de Puerto Rico.
Uso de poliacrilamida como estrategia de control de erosión en un suelo altamente erodado de Puerto Rico.
La alta sedimentación procedente de terrenos dedicados a la agricultura y la construcción es una de las principales fuentes de contaminación de los cuerpos de agua superficiales de...
Impact of Multidisciplinary Stroke Post-Acute Care on Cost and Functional Status: A Prospective Study Based on Propensity Score Matching
Impact of Multidisciplinary Stroke Post-Acute Care on Cost and Functional Status: A Prospective Study Based on Propensity Score Matching
Few papers discuss how the economic burden of patients with stroke receiving rehabilitation courses is related to post-acute care (PAC) programs. This is the first study to explore...
Wastewater-based surveillance for tracing the circulation of Dengue and Chikungunya viruses
Wastewater-based surveillance for tracing the circulation of Dengue and Chikungunya viruses
SummaryBackgroundArboviral diseases, transmitted by infected arthropods, pose significant economic and societal threats. Their global distribution and prevalence have increased in ...


