EXPERIMENTAL FAILURE OF HIP ARTHROPLASTY UNDER TORSION LOADING
View through CrossRef
Polymethylmethacrylate (PMMA) bone cement is strong in compression, however it tends to fail under torsion. Sufficient pressurisation and subsequent interdigitation between cement and bone are critical for the mechanical interlock of cemented orthopaedic implants, and an irregular surface on the acetabular cup is necessary for reasonable fixation at the cup-cement interface. There is limited literature investigating discrepancies in the failure mechanisms of cemented all-polyethylene acetabular cups with and without cement spacers, under torsional loading.In vitro experimental comparison of three groups of polyethylene acetabular prosthesis (PAP) cemented into prepared sawbone hemipelvises:* PAP without PMMA spacers maintaining an equal cement mantle circumferentially. (Group 1 n=3)* PAP without PMMA spacers cemented deliberately ‘bottoming-out’ the implant within the acetabulum. (Group 2 n=3)* PAP with PMMA spacers. (Group 3 n=3)The constructs were tested to torstional failure on a custom designed setup, and statistical analysis done by a one-way ANOVA and Tukey-Welsh test.Group 3 demonstrated superior torsional resistance with a statistically significant torque of 145Nm (SD±12Nm) at failure, compared to group 2 (109Nm, SD±7Nm) and group 1 (99Nm, SD±8Nm). Group 3 experienced failure predominantly at the bone-cement interface, in contrast, Groups 1 and 2 exhibited failure predominantly at the cup-cement interface. There was no significant difference between Group 1 and 2. Qualitative analysis of the failure mode indicates the efficient redistribution of stress throughout the cement mantle, consistent with the greater uniformity of cement.PMMA spacers increase the resistance to torsional failure at the implant-cement interface. Acetabular components without spacers (Groups 1 and 2) failed at the implant-cement interface before the cement-bone interface, at a statistically significantly lower level of torque to failure. Although the PMMA spacers may reduce cement interdigitation at the cement-bone interface the torsional forces required to fail are likely supraphysiological.
British Editorial Society of Bone & Joint Surgery
Title: EXPERIMENTAL FAILURE OF HIP ARTHROPLASTY UNDER TORSION LOADING
Description:
Polymethylmethacrylate (PMMA) bone cement is strong in compression, however it tends to fail under torsion.
Sufficient pressurisation and subsequent interdigitation between cement and bone are critical for the mechanical interlock of cemented orthopaedic implants, and an irregular surface on the acetabular cup is necessary for reasonable fixation at the cup-cement interface.
There is limited literature investigating discrepancies in the failure mechanisms of cemented all-polyethylene acetabular cups with and without cement spacers, under torsional loading.
In vitro experimental comparison of three groups of polyethylene acetabular prosthesis (PAP) cemented into prepared sawbone hemipelvises:* PAP without PMMA spacers maintaining an equal cement mantle circumferentially.
(Group 1 n=3)* PAP without PMMA spacers cemented deliberately ‘bottoming-out’ the implant within the acetabulum.
(Group 2 n=3)* PAP with PMMA spacers.
(Group 3 n=3)The constructs were tested to torstional failure on a custom designed setup, and statistical analysis done by a one-way ANOVA and Tukey-Welsh test.
Group 3 demonstrated superior torsional resistance with a statistically significant torque of 145Nm (SD±12Nm) at failure, compared to group 2 (109Nm, SD±7Nm) and group 1 (99Nm, SD±8Nm).
Group 3 experienced failure predominantly at the bone-cement interface, in contrast, Groups 1 and 2 exhibited failure predominantly at the cup-cement interface.
There was no significant difference between Group 1 and 2.
Qualitative analysis of the failure mode indicates the efficient redistribution of stress throughout the cement mantle, consistent with the greater uniformity of cement.
PMMA spacers increase the resistance to torsional failure at the implant-cement interface.
Acetabular components without spacers (Groups 1 and 2) failed at the implant-cement interface before the cement-bone interface, at a statistically significantly lower level of torque to failure.
Although the PMMA spacers may reduce cement interdigitation at the cement-bone interface the torsional forces required to fail are likely supraphysiological.
Related Results
Physiological and biomechanical factors contributing to the hip adduction angle in female runners
Physiological and biomechanical factors contributing to the hip adduction angle in female runners
Running is a popular form of exercise that is accompanied by many health benefits. However, running also comes with a risk of overuse injuries. Women have a higher risk for overuse...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Comparison of functional outcome between Bipolar Hemiarthroplasty and total Hip Arthroplasty for displaced femoral neck fractures in elderly patients
Comparison of functional outcome between Bipolar Hemiarthroplasty and total Hip Arthroplasty for displaced femoral neck fractures in elderly patients
Objectives: The intention of this study to compare functional outcomes between Total Hip Arthroplasty and Bipolar Hemi Arthroplasty for displaced femoral neck fracture after 3 mont...
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
This paper explores South African hip-hop activist Emile YX?'s work to suggest that he presents an alternative take on mainstream US and South African hip-hop. While it is arguable...
Analysing “Dr Sachin's criteria” for Adnexal Torsion Management & its Variable
Analysing “Dr Sachin's criteria” for Adnexal Torsion Management & its Variable
Introduction Adnexal torsion is 5th most common gynaecological emergency occurring in about 2 - 15% of reproductive age group women, wherein both ovary and fallopian tube twist al...
Association of Hip Radiograph Findings With Pain and Function in Patients Presenting With Low Back Pain
Association of Hip Radiograph Findings With Pain and Function in Patients Presenting With Low Back Pain
AbstractBackgroundRelationships between low back pain (LBP) and the hip in patient cohorts have been described primarily in patients with moderate to severe hip osteoarthritis (OA)...
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
Abstract
Despite advancements in fracture prediction tools and osteoporosis management, hip fractures remain a significant consequence of bone fr...
Evolution of disability in adults with hip arthroplasty: A national longitudinal study
Evolution of disability in adults with hip arthroplasty: A national longitudinal study
AbstractObjectiveTo describe disability in individuals with hip arthroplasty and its evolution over 2 years compared with that in the general population, and to compare the degree ...