Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Venting Corrections Improve the Accuracy of Coupler-Based Simulated Real-Ear Verification for Use with Adult Hearing Aid Fittings

View through CrossRef
Abstract Background Hearing aid responses can be verified with the Real-Ear Aided Response (REAR). Procedures for predicting the REAR from coupler-based verification exist, but have not incorporated corrections for venting, limiting their use and validity for vented and open fittings. A commercially available system for including venting effects in simulated real-ear measurement (S-REM) has recently been developed. Purpose To evaluate the accuracy of a vent-corrected S-REM for predicting the REAR across test levels, for fittings with a wide range of coupling styles including modular domes. Research Design This was a within-subject comparison study using technical measures. Retrospective file review was used to obtain previously measured REARs from 104 fittings in 52 adults and three hearing aid styles. Prospective data collection was used to re-measure each fitting at three test levels using S-REM with and without venting corrections. Comparison of differences by frequency band was performed to assess the impact of the venting correction. Results The vent model reduced low-frequency error by up to 11 dB, and the effects were consistent with the expected effects of venting in hearing aid fitting: fittings with more open dome or tip styles had a larger improvement when the vent model was added. A larger sample of fittings was obtained for dome/sleeve couplings than for custom fittings. Conclusions The vent-corrected S-REM system evaluated in this study provides improved fitting accuracy for dome or sleeve-fitted hearing aids for adults and supports the use of vented S-REM for open fittings. Further studies to examine a representative sample of custom tip or mold fittings, and fittings for children are future directions.
Title: Venting Corrections Improve the Accuracy of Coupler-Based Simulated Real-Ear Verification for Use with Adult Hearing Aid Fittings
Description:
Abstract Background Hearing aid responses can be verified with the Real-Ear Aided Response (REAR).
Procedures for predicting the REAR from coupler-based verification exist, but have not incorporated corrections for venting, limiting their use and validity for vented and open fittings.
A commercially available system for including venting effects in simulated real-ear measurement (S-REM) has recently been developed.
Purpose To evaluate the accuracy of a vent-corrected S-REM for predicting the REAR across test levels, for fittings with a wide range of coupling styles including modular domes.
Research Design This was a within-subject comparison study using technical measures.
Retrospective file review was used to obtain previously measured REARs from 104 fittings in 52 adults and three hearing aid styles.
Prospective data collection was used to re-measure each fitting at three test levels using S-REM with and without venting corrections.
Comparison of differences by frequency band was performed to assess the impact of the venting correction.
Results The vent model reduced low-frequency error by up to 11 dB, and the effects were consistent with the expected effects of venting in hearing aid fitting: fittings with more open dome or tip styles had a larger improvement when the vent model was added.
A larger sample of fittings was obtained for dome/sleeve couplings than for custom fittings.
Conclusions The vent-corrected S-REM system evaluated in this study provides improved fitting accuracy for dome or sleeve-fitted hearing aids for adults and supports the use of vented S-REM for open fittings.
Further studies to examine a representative sample of custom tip or mold fittings, and fittings for children are future directions.

Related Results

Burden of treatment associated with hearing aid use among older adults with hearing loss: a qualitative study
Burden of treatment associated with hearing aid use among older adults with hearing loss: a qualitative study
Abstract Background Treatment burden can affect patients’ ability to carry out tasks or follow recommendations from healthcare providers. Evaluating the burden as...
Pediatric Hearing Aid Management: Parent-Reported Needs for Learning Support
Pediatric Hearing Aid Management: Parent-Reported Needs for Learning Support
Objectives: The aim of this study was to investigate parent learning and support needs related to hearing aid management for young children, and factors that influence ...
Rhinitis-Respect your nose
Rhinitis-Respect your nose
We all know the functions of nose i.e. breathing and smell. The outcome of breathing is to ventilate the lungs and we also know that there is lung compliance which reflects its eff...
Woningcorporaties en Vastgoedontwikkeling
Woningcorporaties en Vastgoedontwikkeling
This summary highlights the findings of the PhD-thesis ‘Woningcorporaties en Vastgoedontwikkeling: Fit for Use’ (‘Housing associations and Real Estate Development: Fit for Use?’). ...
HYDRAULIC TUBE FITTINGS
HYDRAULIC TUBE FITTINGS
<div class="section abstract"> <div class="htmlview paragraph">This standard covers complete general and dimensional specifications for 37 deg flared and flareless typ...
Foreign aid mix and manufactured exports performance in sub-Saharan Africa
Foreign aid mix and manufactured exports performance in sub-Saharan Africa
This study aims at finding out effects of foreign aid mix on manufactured exports performance in Sub-Saharan Africa. This is important as the region has lagged behind on promotion ...
Evaluation of the Zwislocki coupler and KEMAR for use in hearing-aid processing
Evaluation of the Zwislocki coupler and KEMAR for use in hearing-aid processing
A calibrated-probe-tube technique was employed in a comparative investigation of the real-ear frequency response of a hearing aid and the real-ear response as processed through the...