Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Venting Corrections Improve the Accuracy of Coupler-Based Simulated Real-Ear Verification for Use with Adult Hearing Aid Fittings

View through CrossRef
Abstract Background Hearing aid responses can be verified with the Real-Ear Aided Response (REAR). Procedures for predicting the REAR from coupler-based verification exist, but have not incorporated corrections for venting, limiting their use and validity for vented and open fittings. A commercially available system for including venting effects in simulated real-ear measurement (S-REM) has recently been developed. Purpose To evaluate the accuracy of a vent-corrected S-REM for predicting the REAR across test levels, for fittings with a wide range of coupling styles including modular domes. Research Design This was a within-subject comparison study using technical measures. Retrospective file review was used to obtain previously measured REARs from 104 fittings in 52 adults and three hearing aid styles. Prospective data collection was used to re-measure each fitting at three test levels using S-REM with and without venting corrections. Comparison of differences by frequency band was performed to assess the impact of the venting correction. Results The vent model reduced low-frequency error by up to 11 dB, and the effects were consistent with the expected effects of venting in hearing aid fitting: fittings with more open dome or tip styles had a larger improvement when the vent model was added. A larger sample of fittings was obtained for dome/sleeve couplings than for custom fittings. Conclusions The vent-corrected S-REM system evaluated in this study provides improved fitting accuracy for dome or sleeve-fitted hearing aids for adults and supports the use of vented S-REM for open fittings. Further studies to examine a representative sample of custom tip or mold fittings, and fittings for children are future directions.
Title: Venting Corrections Improve the Accuracy of Coupler-Based Simulated Real-Ear Verification for Use with Adult Hearing Aid Fittings
Description:
Abstract Background Hearing aid responses can be verified with the Real-Ear Aided Response (REAR).
Procedures for predicting the REAR from coupler-based verification exist, but have not incorporated corrections for venting, limiting their use and validity for vented and open fittings.
A commercially available system for including venting effects in simulated real-ear measurement (S-REM) has recently been developed.
Purpose To evaluate the accuracy of a vent-corrected S-REM for predicting the REAR across test levels, for fittings with a wide range of coupling styles including modular domes.
Research Design This was a within-subject comparison study using technical measures.
Retrospective file review was used to obtain previously measured REARs from 104 fittings in 52 adults and three hearing aid styles.
Prospective data collection was used to re-measure each fitting at three test levels using S-REM with and without venting corrections.
Comparison of differences by frequency band was performed to assess the impact of the venting correction.
Results The vent model reduced low-frequency error by up to 11 dB, and the effects were consistent with the expected effects of venting in hearing aid fitting: fittings with more open dome or tip styles had a larger improvement when the vent model was added.
A larger sample of fittings was obtained for dome/sleeve couplings than for custom fittings.
Conclusions The vent-corrected S-REM system evaluated in this study provides improved fitting accuracy for dome or sleeve-fitted hearing aids for adults and supports the use of vented S-REM for open fittings.
Further studies to examine a representative sample of custom tip or mold fittings, and fittings for children are future directions.

Related Results

Rhinitis-Respect your nose
Rhinitis-Respect your nose
We all know the functions of nose i.e. breathing and smell. The outcome of breathing is to ventilate the lungs and we also know that there is lung compliance which reflects its eff...
Real-ear Unaided Gain in Wrestlers with Unilateral Cauliflower Ear
Real-ear Unaided Gain in Wrestlers with Unilateral Cauliflower Ear
Background and Aim: Real-Ear Unaided Gain(REUG) can reveal the outer-ear resonance which reflects the effects of body and ear factors. Deformity in the outer ear may change the rea...
HYDRAULIC TUBE FITTINGS
HYDRAULIC TUBE FITTINGS
<div class="section abstract"> <div class="htmlview paragraph">This standard covers complete general and dimensional specifications for 37 deg flared and flareless typ...
Prevention and Control Strategy
Prevention and Control Strategy
Ear diseases are considered as one of the common disorders in small animal practice and the number one cause for veterinary visits among dog owners. Commonly reported clinical sign...
Pattern of hearing loss among patients visiting ENT OPD at Janaki Medical College: A cross sectional study
Pattern of hearing loss among patients visiting ENT OPD at Janaki Medical College: A cross sectional study
Background and Objectives: To study the pattern of hearing loss among patients visiting ENT OPD in Janaki medical college teaching hospital.Material and Methods: The study was cond...
Effect of hearing aids on hearing
Effect of hearing aids on hearing
AbstractWe examined 114 patients aged 10 to 91 years with different kinds of hearing aids fitted in one ear only, the unaided ear acting as a control.They were re‐examined several ...

Back to Top