Javascript must be enabled to continue!
Monochromators for High-Energy Synchrotron Radiation
View through CrossRef
Several monochromators, which are based on the use of cylindrically bent perfect Si crystals, have been constructed at the High Energy X-ray Scattering beamlines of the ESRF. The monochromators provide different focusing conditions, and the energy band-passes are optimized for the needs of different experiments. Formulas are given for calculation of the focal distances, reflectivity curves, and energy distributions. The lay-out of the beamlines follows the Troika concept, where the radiation fan is either split in 3 beams, or the central beam is utilized successively by semi-transparent monochromators to serve three experimental stations simultaneously. The radiation sources are a 7-period permanent magnet asymmetric wiggler and a superconducting wavelength shifter. The critical energies are 45 keV and 96 keV, respectively. The lowest operation energy is 30 keV, and transmission type monochromators have been used up to 1 MeV photon energies. Typical X-ray flux at the sample is 10
Walter de Gruyter GmbH
Title: Monochromators for High-Energy Synchrotron Radiation
Description:
Several monochromators, which are based on the use of cylindrically bent perfect Si crystals, have been constructed at the High Energy X-ray Scattering beamlines of the ESRF.
The monochromators provide different focusing conditions, and the energy band-passes are optimized for the needs of different experiments.
Formulas are given for calculation of the focal distances, reflectivity curves, and energy distributions.
The lay-out of the beamlines follows the Troika concept, where the radiation fan is either split in 3 beams, or the central beam is utilized successively by semi-transparent monochromators to serve three experimental stations simultaneously.
The radiation sources are a 7-period permanent magnet asymmetric wiggler and a superconducting wavelength shifter.
The critical energies are 45 keV and 96 keV, respectively.
The lowest operation energy is 30 keV, and transmission type monochromators have been used up to 1 MeV photon energies.
Typical X-ray flux at the sample is 10.
Related Results
The Use of Synchrotron Radiation in Virology
The Use of Synchrotron Radiation in Virology
Introduction: The demand for new rapid methods for development of medicines for health care is becoming more relevant. Detailed knowledge of the spatial structure of viral proteins...
Monolithic crystal monochromators for synchrotron radiation with order sorting and polarizing properties
Monolithic crystal monochromators for synchrotron radiation with order sorting and polarizing properties
Two novel types of x-ray monochromators which eliminate unwanted higher orders usually present in crystal monochromatized synchrotron radiation beams have been used successfully in...
30 years of Journal of Synchrotron Radiation and synchrotron science
30 years of Journal of Synchrotron Radiation and synchrotron science
Journal of Synchrotron Radiation (JSR) came into being with the publication of its inaugural issue in October 1994 that contained 15 full articles comprising 100 pages. Thirty year...
Studi Paparan Radiasi pada Pekerja Radiasi Cathlab dengan Menggunakan My Dose Mini sebagai Upaya Keselamatan Radiasi di RSUP Adam Malik Medan
Studi Paparan Radiasi pada Pekerja Radiasi Cathlab dengan Menggunakan My Dose Mini sebagai Upaya Keselamatan Radiasi di RSUP Adam Malik Medan
Cathlab radiation workers, when performing interventional procedures, are at high risk of the effects of radiation exposure. The risk of radiation exposure is deterministic and sto...
Synthetic measurements of runaway electron synchrotron emission in the SPARC tokamak
Synthetic measurements of runaway electron synchrotron emission in the SPARC tokamak
With plasma currents up to 8.7 MA, the SPARC tokamak runs the risk of forming multi-MA beams of relativistic “runaway” electrons (REs), which could damage plasma facing components ...
Abstract P3-12-13: Radiation enhancement with cysteine coated platinum nanoparticles
Abstract P3-12-13: Radiation enhancement with cysteine coated platinum nanoparticles
Abstract
Background: Radiation is the current choice treatment for non-operable metastatic breast-brain cancer. When cancer lesions are located in sensitive areas li...
Characteristics of solar radiation at Xiaotang, in the northern marginal zone of the Taklimakan Desert
Characteristics of solar radiation at Xiaotang, in the northern marginal zone of the Taklimakan Desert
The characteristics of solar radiation and the influence of sand and dust on solar radiation in the northern margin of Taklimakan Desert were analyzed using radiation observation d...
Experiments with Very High Energy Synchrotron Radiation
Experiments with Very High Energy Synchrotron Radiation
The use of synchrotron radiation with very high photon energies has become possible only with the latest generation of storage rings. All high-electron-energy synchrotron sources w...

