Javascript must be enabled to continue!
Left Ventricular Endocardial Pacing Improves Resynchronization Therapy in Canine Left Bundle-Branch Hearts
View through CrossRef
Background—
We investigated the benefits of the more physiological activation achieved by left ventricular (LV) endocardial pacing (ENDO) as compared with conventional epicardial (EPI) LV pacing in cardiac resynchronization therapy.
Methods and Results—
In 8 anesthetized dogs with experimental left bundle-branch block, pacing leads were positioned in the right atrium, right ventricle, and at 8 paired (EPI and ENDO) LV sites. Systolic LV pump function was assessed as LVdP/dtmax and stroke work and diastolic function as LVdP/dtmin. Electrical activation and dispersion of repolarization were determined from 122 epicardial and endocardial electrodes and from analysis of the surface ECG. Overall, ENDO-biventricular (BiV) pacing more than doubled the degree of electrical resynchronization and increased the benefit on LVdP/dtmax and stroke work by 90% and 50%, respectively, as compared with EPI-BiV pacing. During single-site LV pacing, the range of AV intervals with a >10% increase in LV resynchronization (79�31 versus 32�24 ms,
P
<0.05) and LVdP/dtmax (92�29 versus 63�39 ms) was significantly longer for ENDO than for EPI pacing. EPI-BiV but not ENDO-BiV pacing created a significant (40�21 ms) transmural dispersion of repolarization.
Conclusions—
Data from this acute animal study indicate that the use of an endocardial LV pacing electrode may increase the efficacy of resynchronization therapy as compared with conventional epicardial resynchronization therapy.
Ovid Technologies (Wolters Kluwer Health)
Title: Left Ventricular Endocardial Pacing Improves Resynchronization Therapy in Canine Left Bundle-Branch Hearts
Description:
Background—
We investigated the benefits of the more physiological activation achieved by left ventricular (LV) endocardial pacing (ENDO) as compared with conventional epicardial (EPI) LV pacing in cardiac resynchronization therapy.
Methods and Results—
In 8 anesthetized dogs with experimental left bundle-branch block, pacing leads were positioned in the right atrium, right ventricle, and at 8 paired (EPI and ENDO) LV sites.
Systolic LV pump function was assessed as LVdP/dtmax and stroke work and diastolic function as LVdP/dtmin.
Electrical activation and dispersion of repolarization were determined from 122 epicardial and endocardial electrodes and from analysis of the surface ECG.
Overall, ENDO-biventricular (BiV) pacing more than doubled the degree of electrical resynchronization and increased the benefit on LVdP/dtmax and stroke work by 90% and 50%, respectively, as compared with EPI-BiV pacing.
During single-site LV pacing, the range of AV intervals with a >10% increase in LV resynchronization (79�31 versus 32�24 ms,
P
<0.
05) and LVdP/dtmax (92�29 versus 63�39 ms) was significantly longer for ENDO than for EPI pacing.
EPI-BiV but not ENDO-BiV pacing created a significant (40�21 ms) transmural dispersion of repolarization.
Conclusions—
Data from this acute animal study indicate that the use of an endocardial LV pacing electrode may increase the efficacy of resynchronization therapy as compared with conventional epicardial resynchronization therapy.
Related Results
Predictive value of left atrial remodeling for response to cardiac
resynchronization therapy
Predictive value of left atrial remodeling for response to cardiac
resynchronization therapy
Aim: Response to cardiac resynchronization therapy varies significantly among
patients, with one third of them failing to demonstrate left ventricular reverse
...
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Potential for leadless left bundle branch pacing for cardiac resynchronization: a case report
Potential for leadless left bundle branch pacing for cardiac resynchronization: a case report
Introduction: Left bundle branch pacing is a recently described form of
conduction system pacing which can correct left-bundle branch block and
deliver cardiac resynchronization th...
Long‐Term Follow‐up Impact of Dual‐Chamber Pacing on Patients with Hypertrophic Obstructive Cardiomyopathy
Long‐Term Follow‐up Impact of Dual‐Chamber Pacing on Patients with Hypertrophic Obstructive Cardiomyopathy
BackgroundPacing has been proposed as a treatment for patients with hypertrophic obstructive cardiomyopathy (HOCM), but there are few studies with long‐term follow‐up. We evaluated...
Acute Changes in Cardiac Synchrony and Output According to RV Pacing Sites in Koreans with Normal Cardiac Function
Acute Changes in Cardiac Synchrony and Output According to RV Pacing Sites in Koreans with Normal Cardiac Function
Introduction: The synchrony of the pacing heart can be affected by the right ventricular (RV) pacing site and is crucial to cardiac function in pacemaker recipients. We evaluated t...
Effects of Right Ventricular Nonapical Pacing on Cardiac Function: A Meta‐analysis of Randomized Controlled Trials
Effects of Right Ventricular Nonapical Pacing on Cardiac Function: A Meta‐analysis of Randomized Controlled Trials
BackgroundA meta‐analysis of randomized controlled trials (RCTs) was conducted to compare the effects of right ventricular nonapical (RVNA) and right ventricular apical (RVA) pacin...
Changes in pacing variation with increasing race duration in ultra-triathlon races
Changes in pacing variation with increasing race duration in ultra-triathlon races
Abstract
Background: Despite the increasing scientific interest in the relationship between pacing and performance in endurance sports, little information is available abou...
Alternative pacing strategies for optimal cardiac resynchronization therapy
Alternative pacing strategies for optimal cardiac resynchronization therapy
Cardiac resynchronization therapy (CRT) via biventricular pacing (BVP) improves morbidity, mortality, and quality of life, especially in subsets of patients with impaired cardiac f...

