G.O.Joe: A novel non-commercial software tool for the processing of LA-ICP-MS data
View through CrossRef
The coupling of laser ablation systems with inductively coupled plasma-mass spectrometers (LA-ICP-MS) was introduced in the 1980s. Since then, this technique has become indispensable for rapid, in-situ trace element and isotopic analysis of both natural and synthetic solid samples. Its applications extend across various fields, including chemistry, material science, geosciences as well as biological and environmental analysis, bio-imaging and forensic investigations. However, analytical advances are still needed to overcome problems in trace element analysis using LA-ICP-MS caused e.g. by interferences that cannot be solved instrumentally.The novel and non-commercial software tool G.O.Joe is designed to facilitate the calculation of trace element mass fractions in solid samples obtained by LA-ICP-MS analysis. It is written in the Dart programming language using the Flutter framework and operates completely web-based, eliminating the need for installation and allowing access from any location with an internet connection. Since the calculation of the data itself is performed on the user’s computer, no upload of measured data to the G.O.Joe-server is necessary thereby maximizing data safety. In addition to a quick and efficient processing of large datasets (>400 analyses), G.O.Joe includes several types of optional interference corrections.The intuitive user interface of G.O.Joe simplifies the workflow during data evaluation, including straightforward selections of peak- and background signals, importing instrument settings and reference material compositions as well as mass fractions of the internal standard to convert the measured raw signals into element mass fractions. To ensure a transparency in data processing, the results file (.xlsx) includes the calculated element mass fractions, associated statistical parameters as well as input data alongside instrument settings. In addition, the user can download a more comprehensive file with the results after each step of the calculation. The detailed Major advantages of the software are the implemented correction measures for isobaric interferences and abundance sensitivity.G.O.Joe’s key features are presented by processing the mineral chemical analyses of two case studies, including trace element analyses of tungstates (e.g., scheelite) and silicates (e.g., garnet). Conclusively, G.O.Joe is a time-efficient, transparent and easy-to-use software, appealing to both experienced LA-ICP-MS users as well as newcomers to LA-ICP-MS data analysis. More details and the latest version of G.O.Joe are available at the following link: https://www.gojoe.software
Title: G.O.Joe: A novel non-commercial software tool for the processing of LA-ICP-MS data
Description:
The coupling of laser ablation systems with inductively coupled plasma-mass spectrometers (LA-ICP-MS) was introduced in the 1980s.
Since then, this technique has become indispensable for rapid, in-situ trace element and isotopic analysis of both natural and synthetic solid samples.
Its applications extend across various fields, including chemistry, material science, geosciences as well as biological and environmental analysis, bio-imaging and forensic investigations.
However, analytical advances are still needed to overcome problems in trace element analysis using LA-ICP-MS caused e.
g.
by interferences that cannot be solved instrumentally.
The novel and non-commercial software tool G.
O.
Joe is designed to facilitate the calculation of trace element mass fractions in solid samples obtained by LA-ICP-MS analysis.
It is written in the Dart programming language using the Flutter framework and operates completely web-based, eliminating the need for installation and allowing access from any location with an internet connection.
Since the calculation of the data itself is performed on the user’s computer, no upload of measured data to the G.
O.
Joe-server is necessary thereby maximizing data safety.
In addition to a quick and efficient processing of large datasets (>400 analyses), G.
O.
Joe includes several types of optional interference corrections.
The intuitive user interface of G.
O.
Joe simplifies the workflow during data evaluation, including straightforward selections of peak- and background signals, importing instrument settings and reference material compositions as well as mass fractions of the internal standard to convert the measured raw signals into element mass fractions.
To ensure a transparency in data processing, the results file (.
xlsx) includes the calculated element mass fractions, associated statistical parameters as well as input data alongside instrument settings.
In addition, the user can download a more comprehensive file with the results after each step of the calculation.
The detailed Major advantages of the software are the implemented correction measures for isobaric interferences and abundance sensitivity.
G.
O.
Joe’s key features are presented by processing the mineral chemical analyses of two case studies, including trace element analyses of tungstates (e.
g.
, scheelite) and silicates (e.
g.
, garnet).
Conclusively, G.
O.
Joe is a time-efficient, transparent and easy-to-use software, appealing to both experienced LA-ICP-MS users as well as newcomers to LA-ICP-MS data analysis.
More details and the latest version of G.
O.
Joe are available at the following link: https://www.
gojoe.
software.
Related Results
Comparative Investigation of Different Telemetric Methods for Measuring Intracranial Pressure: A Prospective Pilot Study
Comparative Investigation of Different Telemetric Methods for Measuring Intracranial Pressure: A Prospective Pilot Study
Abstract
Objectives: Measurement of intracranial pressure (ICP) plays an important role in long-term monitoring and neuro-intensive treatment of patients with a cerebral sh...
Positive end-expiratory pressure increases intracranial pressure but not pressure reactivity index in supine and prone positions: a porcine model study
Positive end-expiratory pressure increases intracranial pressure but not pressure reactivity index in supine and prone positions: a porcine model study
IntroductionPositive end-expiratory pressure (PEEP) and prone positioning can improve gas exchange by promoting uniform lung aeration. However, elevated ventilation pressures may i...
Extracranial pressure (ECP) monitoring in severe traumatic brain injury (TBI): A prospective study validating intra-abdominal pressure (IAP) measurement for predicting intracranial pressure (ICP)
Extracranial pressure (ECP) monitoring in severe traumatic brain injury (TBI): A prospective study validating intra-abdominal pressure (IAP) measurement for predicting intracranial pressure (ICP)
Background:
Intracranial pressure (ICP)--guided therapy is the standard of care in the management of severe traumatic brain injury (TBI). Ideal ICP monitoring technique is not yet...
Advances in ICP-MS technology and the application of multi-element geochemistry to exploration
Advances in ICP-MS technology and the application of multi-element geochemistry to exploration
There have been several advances in inductively coupled plasma-mass spectrometer (ICP-MS) analytical technologies in the last decade. Collision/reaction cell ICP-MS and triple quad...
Optimising tool wear and workpiece condition monitoring via cyber-physical systems for smart manufacturing
Optimising tool wear and workpiece condition monitoring via cyber-physical systems for smart manufacturing
Smart manufacturing has been developed since the introduction of Industry 4.0. It consists of resource sharing and networking, predictive engineering, and material and data analyti...
Abstract P447: Intracranial Pressure and Cerebral Perfusion Pressure Monitoring in Spontaneous Intracranial Hemorrhage: A Secondary Analysis of the Mistie III Trial
Abstract P447: Intracranial Pressure and Cerebral Perfusion Pressure Monitoring in Spontaneous Intracranial Hemorrhage: A Secondary Analysis of the Mistie III Trial
Introduction:
Intracerebral hemorrhage (ICH) management guidelines recommend maintaining intracranial pressure (ICP) <20 and cerebral perfusion pressure (CPP) betwee...
Craniotomy for supratentorial brain tumors: risk factors for brain swelling after opening the dura mater
Craniotomy for supratentorial brain tumors: risk factors for brain swelling after opening the dura mater
Object. Cerebral swelling often occurs during craniotomy for cerebral tumors. The primary aim in this study was to determine risk factors (intracranial pressure [ICP], patient char...
Effective ICP reduction by decompressive craniectomy in patients with severe traumatic brain injury treated by an ICP-targeted therapy
Effective ICP reduction by decompressive craniectomy in patients with severe traumatic brain injury treated by an ICP-targeted therapy
Severe traumatic brain injury (TBI) is one of the major causes of death in younger age groups. In Umea, Sweden, an intracranial pressure (ICP) targeted therapy protocol, the Lund c...