Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The Dewey monitor: Pulse oximetry can independently detect hypoxia in a rebreather diver

View through CrossRef
Rebreather diving has one of the highest fatality rates per man hour of any diving activity in the world. The leading cause of death is hypoxia, typically from equipment or procedural failures. Hypoxia causes very few symptoms prior to causing loss of consciousness. Additionally, since the electronics responsible for controlling oxygen levels in rebreathers often control their alarm systems, frequently divers do not receive any external warnings. This study investigated the use of a forehead pulse oximeter as an independent warning device in the event of rebreather failure. Ten test subjects (seven male, three female, median age 29, range 26-35) exercised at a targeted rate of 2 L/minute oxygen consumption while on a non-functional rebreather breathing loop (mean consumption achieved 2.09 ± 0.36 L/minute). Each subject was tested both at the surface and at pressurized depth of 77 fsw (starting pO2=0.7 atm). The data show that a pulse oximeter could be used to provide an Mk 16 rebreather diver with a minimum mean of 49 seconds (± 17 seconds SD) of warning time after a noticeable change in blood oxygen saturation (SpO2 ≤ 95%) but before any risk of loss of consciousness (calculated SpO2 ≤ 80%), so that the diver may take mitigating actions. No statistical difference in warning time was found between the tests at surface and at 77 fsw (P=0.46).
Title: The Dewey monitor: Pulse oximetry can independently detect hypoxia in a rebreather diver
Description:
Rebreather diving has one of the highest fatality rates per man hour of any diving activity in the world.
The leading cause of death is hypoxia, typically from equipment or procedural failures.
Hypoxia causes very few symptoms prior to causing loss of consciousness.
Additionally, since the electronics responsible for controlling oxygen levels in rebreathers often control their alarm systems, frequently divers do not receive any external warnings.
This study investigated the use of a forehead pulse oximeter as an independent warning device in the event of rebreather failure.
Ten test subjects (seven male, three female, median age 29, range 26-35) exercised at a targeted rate of 2 L/minute oxygen consumption while on a non-functional rebreather breathing loop (mean consumption achieved 2.
09 ± 0.
36 L/minute).
Each subject was tested both at the surface and at pressurized depth of 77 fsw (starting pO2=0.
7 atm).
The data show that a pulse oximeter could be used to provide an Mk 16 rebreather diver with a minimum mean of 49 seconds (± 17 seconds SD) of warning time after a noticeable change in blood oxygen saturation (SpO2 ≤ 95%) but before any risk of loss of consciousness (calculated SpO2 ≤ 80%), so that the diver may take mitigating actions.
No statistical difference in warning time was found between the tests at surface and at 77 fsw (P=0.
46).

Related Results

Pulse oximeter to detect peripheral oxygen saturation in underwater rebreather ECCR diver: a preliminary study
Pulse oximeter to detect peripheral oxygen saturation in underwater rebreather ECCR diver: a preliminary study
Hypoxia is one of the main problems an underwater diver may have to face. The probability of experiencing hypoxia is related to the type of dive and the equipment used. Hypoxia in ...
Pulse Oximetry in the Evaluation of Peripheral Vascular Disease
Pulse Oximetry in the Evaluation of Peripheral Vascular Disease
The role of pulse oximetry in the evaluation of peripheral vascular disease (PVD) was investigated. In addition, the value of elevating the limb to improve the sensitivity of detec...
Divers Acoustic Communications
Divers Acoustic Communications
ABSTRACT A brief history of divers acoustic communications is given, the needs are defined, several technical approaches are described, and development past, pres...
GW24-e2990 The expression of rock in cardiomyocte exposed to hypoxia and its role in cardiomyocte injury
GW24-e2990 The expression of rock in cardiomyocte exposed to hypoxia and its role in cardiomyocte injury
Objectives Using cultured myocardial cells in vitro and establishing virtual hypoxia environment of cardiomyocyte apoptosis model, to observe the expression of Ro...
Hypoxia signatures in closed-circuit rebreather divers
Hypoxia signatures in closed-circuit rebreather divers
Introduction: Faults or errors during use of closed-circuit rebreathers (CCRs) can cause hypoxia. Military aviators face a similar risk of hypoxia and undergo awareness training to...
Clinical use of pulse oximetry in adults
Clinical use of pulse oximetry in adults
The article is devoted to the practical aspects of pulse oximetry. Pulse oximetry is a photoplethysmographic method for determining heart rate and the percentage of oxyhemoglobin i...
Beyond Rhetoric
Beyond Rhetoric
While John Dewey is an icon of American education and his work object of comprehensive studies, this book ventures to fill gaps that have been neglected by previous research. In pa...
John Dewey, Albert Barnes, and the Continuity of Art and Life
John Dewey, Albert Barnes, and the Continuity of Art and Life
This carefully researched book offers a dynamic and expansive Deweyan vision for the arts and education. This (re)vision acknowledges the influence on Dewey’s aesthetics of art col...

Back to Top