Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Classification with a Deferral Option and Low-Trust Filtering for Automated Seizure Detection

View through CrossRef
Wearable technology will become available and allow prolonged electroencephalography (EEG) monitoring in the home environment of patients with epilepsy. Neurologists analyse the EEG visually and annotate all seizures, which patients often under report. Visual analysis of a 24 hour EEG recording typically takes one to two hours. Reliable automated seizure detection algorithms will be crucial to reduce this analysis. We study a dataset of behind-the-ear EEG measurements. Our first aim was to develop a methodology to reduce the EEG dataset by classifying part of the data automatically, while retaining 100% detection sensitivity (DS). Prediction confidences are determined by temperature scaling of the classification model outputs and trust scores. A DS of approximately 90% (99%) can be achieved when automatically classifying around 90% (60%) of the data. Perfect DS can be achieved when automatically classifying 50% of the data. Our second contribution demonstrates that a common modelling strategy, where predictions from several short EEG segments are used to obtain a final prediction, can be improved by filtering out untrustworthy segments with low trust scores. The false detection rate shows a relative decrease between 21% and 43%, and the DS shows a small increase or decrease.
Title: Classification with a Deferral Option and Low-Trust Filtering for Automated Seizure Detection
Description:
Wearable technology will become available and allow prolonged electroencephalography (EEG) monitoring in the home environment of patients with epilepsy.
Neurologists analyse the EEG visually and annotate all seizures, which patients often under report.
Visual analysis of a 24 hour EEG recording typically takes one to two hours.
Reliable automated seizure detection algorithms will be crucial to reduce this analysis.
We study a dataset of behind-the-ear EEG measurements.
Our first aim was to develop a methodology to reduce the EEG dataset by classifying part of the data automatically, while retaining 100% detection sensitivity (DS).
Prediction confidences are determined by temperature scaling of the classification model outputs and trust scores.
A DS of approximately 90% (99%) can be achieved when automatically classifying around 90% (60%) of the data.
Perfect DS can be achieved when automatically classifying 50% of the data.
Our second contribution demonstrates that a common modelling strategy, where predictions from several short EEG segments are used to obtain a final prediction, can be improved by filtering out untrustworthy segments with low trust scores.
The false detection rate shows a relative decrease between 21% and 43%, and the DS shows a small increase or decrease.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
The influence of demographic and lifestyle factors on blood donation delay among student population: a retrospective study
The influence of demographic and lifestyle factors on blood donation delay among student population: a retrospective study
ObjectiveThis study analysed blood donation deferral trends, reasons and demographic/lifestyle characteristics among students in Huzhou City. The aim was to understand the health s...
Diagnostic role of serum prolactin level in different kinds of seizure and seizure-like episode in children: A hospital-based study
Diagnostic role of serum prolactin level in different kinds of seizure and seizure-like episode in children: A hospital-based study
Background: Serum prolactin level has been previously used in distinguishing epileptic seizure from non-epileptic seizure, as prolactin level usually rises following an epileptic s...
Autonomy on Trial
Autonomy on Trial
Photo by CHUTTERSNAP on Unsplash Abstract This paper critically examines how US bioethics and health law conceptualize patient autonomy, contrasting the rights-based, individualist...
On‐site deferral of whole blood and plasma donors in the Netherlands between 2006 and 2013
On‐site deferral of whole blood and plasma donors in the Netherlands between 2006 and 2013
Background and ObjectivesDonor physicians at Sanquin Blood Supply reported increasing on‐site deferral rates. The aim of this study was to investigate the change over time in on‐si...
Banking system trust, bank trust, and bank loyalty
Banking system trust, bank trust, and bank loyalty
Purpose The purpose of this paper is to test a model of banking system trust as an antecedent of bank trust and bank loyalty. Six determinants of trust and loyalty are included: co...
Seizure Detection Devices
Seizure Detection Devices
Goals of automated detection of epileptic seizures using wearable devices include objective documentation of seizures, prevention of sudden unexpected death in epilepsy (SUDEP) and...

Back to Top