Tantalum-doped Mesoporous Bioactive Glass Fibers and Powders for Hemostatic Applications

View through CrossRef
<p>Hemorrhage is the leading cause of battlefield deaths and second most common cause for civilian mortality worldwide, and mesoporous BGs (MBGs), are candidates for hemostasis. </p> <p>Novel tantalum-containing MBG (Ta-MBG) powders: (80-<em>x</em>)SiO<sub>2</sub>-15CaO-5P<sub>2</sub>O<sub>5</sub>-<em>x</em>Ta<sub>2</sub>O<sub>5</sub> with <em>x</em>=0 (0Ta), 0.5 (0.5Ta), 1 (1Ta), 5 (5Ta), and 10 (10Ta), were developed using a sol-gel process. The powders were non-cytotoxic to bovine fibroblasts (MTT assay) and had a negative surface charge (-20.4 to -24.8 mV measured using zeta potential, ZP) which enhanced the intrinsic coagulation pathway (assessed using activated partial thromboplastin time, APTT). The powders (except 10Ta) showed lower hemolysis and APTT than ‘no treatment’ (physiological clotting). Among Ta-MBGs, 5Ta (11.6±5.8 sec) reduced APTT significantly compared to 1Ta (31.5±5.8 sec) and 10Ta (28±5.9 sec). Furthermore, lethal-liver-injury porcine trials of two best powders (5Ta and 1Ta) confirmed 5Ta as the most suitable composition for hemostasis. </p> <p>Powder hemostats pose handling and functional challenges in the wet surgical field; to address these challenges, the hemostatic compositions (0Ta, 0.5Ta, 1Ta, and 5Ta) were fabricated as fibrous mats using a combination of sol-gel route and electrospinning technique. </p> <p>The state-of-the-art analytical techniques showed fibers encompassing a hierarchical micro (0.5-2 µm) and nano (1-8 nm) porosity while the powders displaying unimodal mesopores (4 nm) leading to higher (298-374 m<sup>2</sup>g<sup>-1</sup>) surface areas than equivalent fibers (5-61 m<sup>2</sup>g<sup>-1</sup>). The ZP of the fibers (-26.2 to -48.7 mV) was better for hemostasis and stability in the wet environment than powders (-20.4 to -24.8 mV). The fibers were also non-cytotoxic to primary rat fibroblasts. The powders showed higher non-bridging oxygen-silicon (Si-NBO) bonds leading to higher ionic release than the fibers. Lower Si-NBO, lesser ionic release and more negative ZP provide advantageous stability to the fibers in wet environments. No significant differences between the bleeding times of powders and fibres was found using murine tail-bleed models. APTT suggested 1Ta composition to be most suitable among fibers to enhance hemostasis.</p> <p>It is concluded that 5Ta and 1Ta provide the best compositions to enhance hemostasis among powders and fibers, respectively. The structural and functional differences/similarities of two forms were not reflected in their hemostatic capabilities. Finally, the fibers provide a stable matrix for clot formation that can compress the bleeding site.</p>
Ryerson University Library and Archives
Title: Tantalum-doped Mesoporous Bioactive Glass Fibers and Powders for Hemostatic Applications
Description:
<p>Hemorrhage is the leading cause of battlefield deaths and second most common cause for civilian mortality worldwide, and mesoporous BGs (MBGs), are candidates for hemostasis.
 </p> <p>Novel tantalum-containing MBG (Ta-MBG) powders: (80-<em>x</em>)SiO<sub>2</sub>-15CaO-5P<sub>2</sub>O<sub>5</sub>-<em>x</em>Ta<sub>2</sub>O<sub>5</sub> with <em>x</em>=0 (0Ta), 0.
5 (0.
5Ta), 1 (1Ta), 5 (5Ta), and 10 (10Ta), were developed using a sol-gel process.
The powders were non-cytotoxic to bovine fibroblasts (MTT assay) and had a negative surface charge (-20.
4 to -24.
8 mV measured using zeta potential, ZP) which enhanced the intrinsic coagulation pathway (assessed using activated partial thromboplastin time, APTT).
The powders (except 10Ta) showed lower hemolysis and APTT than ‘no treatment’ (physiological clotting).
Among Ta-MBGs, 5Ta (11.
6±5.
8 sec) reduced APTT significantly compared to 1Ta (31.
5±5.
8 sec) and 10Ta (28±5.
9 sec).
Furthermore, lethal-liver-injury porcine trials of two best powders (5Ta and 1Ta) confirmed 5Ta as the most suitable composition for hemostasis.
 </p> <p>Powder hemostats pose handling and functional challenges in the wet surgical field; to address these challenges, the hemostatic compositions (0Ta, 0.
5Ta, 1Ta, and 5Ta) were fabricated as fibrous mats using a combination of sol-gel route and electrospinning technique.
 </p> <p>The state-of-the-art analytical techniques showed fibers encompassing a hierarchical micro (0.
5-2 µm) and nano (1-8 nm) porosity while the powders displaying unimodal mesopores (4 nm) leading to higher (298-374 m<sup>2</sup>g<sup>-1</sup>) surface areas than equivalent fibers (5-61 m<sup>2</sup>g<sup>-1</sup>).
The ZP of the fibers (-26.
2 to -48.
7 mV) was better for hemostasis and stability in the wet environment than powders (-20.
4 to -24.
8 mV).
The fibers were also non-cytotoxic to primary rat fibroblasts.
The powders showed higher non-bridging oxygen-silicon (Si-NBO) bonds leading to higher ionic release than the fibers.
Lower Si-NBO, lesser ionic release and more negative ZP provide advantageous stability to the fibers in wet environments.
No significant differences between the bleeding times of powders and fibres was found using murine tail-bleed models.
APTT suggested 1Ta composition to be most suitable among fibers to enhance hemostasis.
</p> <p>It is concluded that 5Ta and 1Ta provide the best compositions to enhance hemostasis among powders and fibers, respectively.
The structural and functional differences/similarities of two forms were not reflected in their hemostatic capabilities.
Finally, the fibers provide a stable matrix for clot formation that can compress the bleeding site.
</p>.

Related Results

Tantalum-doped Mesoporous Bioactive Glass Fibers and Powders for Hemostatic Applications
Tantalum-doped Mesoporous Bioactive Glass Fibers and Powders for Hemostatic Applications
<p>Hemorrhage is the leading cause of battlefield deaths and second most common cause for civilian mortality worldwide, and mesoporous BGs (MBGs), are candidates for hemostas...
Unveiling the third dimension of glass
Unveiling the third dimension of glass
Glass as a material has always fascinated architects. Its inherent transparency has given us the ability to create diaphanous barriers between the interior and the exterior that al...
Asbestos
Asbestos
Abstract The term asbestos is a generic designation referring usually to six types of naturally occurring mineral fibers that are or have been commercially exploited. The...
Recycling of Composite Metallic Coatings
Recycling of Composite Metallic Coatings
Recycling of bimetallic composite coatings presents challenging opportunities as both the alloy substrates and coatings contain valuable resources for recovery and reuse. Several c...
Hemostatic materials in wound care
Hemostatic materials in wound care
AbstractBlood plays an essential role in the human body. Hemorrhage is a critical cause of both military and civilian casualties. The human body has its own hemostatic mechanism th...
Hardness Improvement of Chalcogenide Glasses
Hardness Improvement of Chalcogenide Glasses
In and Bi were doped into 30Ge10Sb60Se and 27.5Ge12.5Sb60Se glasses to improve hardness. While Bi did not have any influence on hardness, In made 10% hardness improvement in 27.5Ge...
Retrieval Analysis and Finite Element Modeling of Orthopaedic Porous-Coated Implants
Retrieval Analysis and Finite Element Modeling of Orthopaedic Porous-Coated Implants
Recent Nationwide Inpatient Sample (NIS) studies have shown that implant loosening remains one of the common reasons for revision in total joint replacement. In an effort to reduce...