Multifrequency bioimpedance by spectroscopy vs. routine methods in the management of hydration status in peritoneal dialysis patients: A randomized control trial
View through CrossRef
BackgroundOverhydration (OH) is common in peritoneal dialysis (PD) and increases the cardiovascular risk. Multifrequency bioimpedance spectroscopy (BIS) has been proposed to estimate the hydration in dialysis. Our objective was to evaluate if BIS is superior than control based on clinical assessment plus single-frequency bioimpedance (SF-BIA) on the fluid control and intermediate cardiovascular outcomes.MethodsRandomized controlled study in adult PD patients, with a 9-month follow-up, allocated into two groups: control and BIS. Data were collected from medical records. SF-BIA and BIS, laboratory exams, ambulatory blood pressure monitoring, echocardiography (ECHO), and pulse wave velocity (PWV) were evaluated. The BIS data were available to the medical team only in BIS group.Results34 patients completed the study, 17 in each group. At the endpoint the BIS group had a significant (p < 0.05) greater proportion of patients with OH/extracellular water (OH/ECW%) ≤ 15% than the control (94.1% vs. 52.9%), and a lower OH mean (2.1 ± 1.6 vs. 0.9 ± 1.1 L). The control group has a significant increase in the tumor necrosis factor alpha median concentration from baseline to six [11.9 (6.0–24.1) vs. 44.7 (9.4–70.6) pg/ml] and 9 months [11.9 (6.0–24.1) vs. 39.4 (27.9–62.6) pg/ml], and in the N-terminal fragment of pro-B-type natriuretic peptide median [239 (171.5–360.5) vs. 356 (219–1,555) pg/ml]. For cardiovascular parameters, BIS group presented a significant reduction in radial PWV [7.7 (6.9–9.2) vs. 6.5 (5.5–8.4) m/s] at 9 month, while in the control presented a significant increase in mean central systolic blood pressure (BP) (106.8 ± 11.2 vs. 117.6 ± 16.5 mmHg) and in central diastolic BP (90.4 ± 9.8 vs. 103.3 ± 12.5 mmHg) at 9 months. The left ventricular mass (LVM)/body surface presented a significant reduction in the control (109.6 ± 30.8 vs. 101.2 ± 28.9 g/m2) and BIS group (107.7 ± 24.9 vs. 96.1 ± 27.0 g/m2) at 9 months.ConclusionThe results suggest BIS is superior than the clinical evaluation plus SF-BIA for the fluid control of PD patients.Clinical trial registration[https://www.ClinicalTrials.gov], identifier [RBR-10k8j3bx].
Title: Multifrequency bioimpedance by spectroscopy vs. routine methods in the management of hydration status in peritoneal dialysis patients: A randomized control trial
Description:
BackgroundOverhydration (OH) is common in peritoneal dialysis (PD) and increases the cardiovascular risk.
Multifrequency bioimpedance spectroscopy (BIS) has been proposed to estimate the hydration in dialysis.
Our objective was to evaluate if BIS is superior than control based on clinical assessment plus single-frequency bioimpedance (SF-BIA) on the fluid control and intermediate cardiovascular outcomes.
MethodsRandomized controlled study in adult PD patients, with a 9-month follow-up, allocated into two groups: control and BIS.
Data were collected from medical records.
SF-BIA and BIS, laboratory exams, ambulatory blood pressure monitoring, echocardiography (ECHO), and pulse wave velocity (PWV) were evaluated.
The BIS data were available to the medical team only in BIS group.
Results34 patients completed the study, 17 in each group.
At the endpoint the BIS group had a significant (p < 0.
05) greater proportion of patients with OH/extracellular water (OH/ECW%) ≤ 15% than the control (94.
1% vs.
52.
9%), and a lower OH mean (2.
1 ± 1.
6 vs.
0.
9 ± 1.
1 L).
The control group has a significant increase in the tumor necrosis factor alpha median concentration from baseline to six [11.
9 (6.
0–24.
1) vs.
44.
7 (9.
4–70.
6) pg/ml] and 9 months [11.
9 (6.
0–24.
1) vs.
39.
4 (27.
9–62.
6) pg/ml], and in the N-terminal fragment of pro-B-type natriuretic peptide median [239 (171.
5–360.
5) vs.
356 (219–1,555) pg/ml].
For cardiovascular parameters, BIS group presented a significant reduction in radial PWV [7.
7 (6.
9–9.
2) vs.
6.
5 (5.
5–8.
4) m/s] at 9 month, while in the control presented a significant increase in mean central systolic blood pressure (BP) (106.
8 ± 11.
2 vs.
117.
6 ± 16.
5 mmHg) and in central diastolic BP (90.
4 ± 9.
8 vs.
103.
3 ± 12.
5 mmHg) at 9 months.
The left ventricular mass (LVM)/body surface presented a significant reduction in the control (109.
6 ± 30.
8 vs.
101.
2 ± 28.
9 g/m2) and BIS group (107.
7 ± 24.
9 vs.
96.
1 ± 27.
0 g/m2) at 9 months.
ConclusionThe results suggest BIS is superior than the clinical evaluation plus SF-BIA for the fluid control of PD patients.
Clinical trial registration[https://www.
ClinicalTrials.
gov], identifier [RBR-10k8j3bx].
Related Results
Rethinking Anticoagulation in Kidney Disease and Kidney Transplantation
Rethinking Anticoagulation in Kidney Disease and Kidney Transplantation
BackgroundA clinical dilemma exists in patients with CKD, ESKD, and after kidney transplantation, as they face concurrent risks of both thromboembolic and hemorrhagic complications...
Safety and Efficacy of Atezolizumab in Ovarian Cancer
Safety and Efficacy of Atezolizumab in Ovarian Cancer
Abstract
Introduction
Although the efficacy of PD-L1 blockade has been evaluated in analyses that combine pharmacologically distinct antibodies, the specific efficacy and safety of...
Assessment of implementation of the Pradhan Mantri national dialysis Programme in Hospitals in Delhi
Assessment of implementation of the Pradhan Mantri national dialysis Programme in Hospitals in Delhi
Background: Annual-demand for haemodialysis-sessions in India is 3.4 Crores. To make Renal-care-services affordable to APL and free to BPL, Ministry of Health and Family Welfare la...
#1608 Use of intraperitoneal hydration by peritoneal dialysis fluid as a complementary palliative therapy in peritoneal dialysis patients
#1608 Use of intraperitoneal hydration by peritoneal dialysis fluid as a complementary palliative therapy in peritoneal dialysis patients
Abstract
Background and Aims
End life care should manage pain, other distressing symptoms and guarantee sufficient hydration. It...
Abstract B140: Autologous human growing tumor model and its immunological relevance for cancer immunology research
Abstract B140: Autologous human growing tumor model and its immunological relevance for cancer immunology research
Abstract
Background: Tumors grow in accordance with immunoediting. If we can see the changes of immune characteristics in the microenvironment during tumor growth, w...
Factors Associated With Dialysis Withdrawal In Dialysis Patients
Factors Associated With Dialysis Withdrawal In Dialysis Patients
Abstract
Background: Research on the factors associated with dialysis withdrawal in dialysis patients has been limited. Authors have used different definitions for dialysis...
FC 117TIME TRENDS IN PROBABILITY OF STARTING HOME DIALYSIS OVER A 20 YEAR PERIOD: A DUTCH REGISTRY STUDY
FC 117TIME TRENDS IN PROBABILITY OF STARTING HOME DIALYSIS OVER A 20 YEAR PERIOD: A DUTCH REGISTRY STUDY
Abstract
Background and Aims
A growing number of patients suffers from End Stage Kidney Disease(ESKD), causing a logistical and ...
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract
Introduction
Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...