Javascript must be enabled to continue!
ELIMINATION OF DELAYS TO OCULOMOTOR RESEARCH EQUIPMENT / OKULOMOTORINIŲ TYRIMŲ ĮRANGOS VĖLINIMO ELIMINAVIMAS
View through CrossRef
Optic stimulus used for human oculomotor system or eye-hand coordination researches is often represented on a computer screen. They must be synchronised with the eye tracker to achieve the accurate results of the conducted experiments. Relation between stimulus presence and eye image capturing times can be defined only with reference to knowledge of all system delays. The suggested research evaluates our eye tracking system delay and propose a practical method for measuring and evaluating delays to the computer graphic subsystem. Experimental research shows that LC Technologies eye tracker reports gaze angle with 28 ms lag and the average stimulus lag of the computer graphic subsystem is 9,5 ms.
Santrauka
Atliekant žmogaus okulomotorinės sistemos ar akies ir rankos koordinacijos tyrimus, naudojami optiniai stimulai, kurie atvaizduojami kompiuterio vaizduoklyje. Norint gauti tikslius tyrimų rezultatus, reikalinga šių stimulų sinchronizacija su žvilgsnio krypties registravimo įranga. Stimulo pasirodymo ir akies vaizdo užfiksavimo laikus sutapdinti galima tik įvertinus visas sistemos vėlinimo dedamąsias. Darbe apskaičiuotas naudojamos akių judesių registravimo įrangos vėlinimas ir pasiūlytas praktinis metodas kompiuterio grafinės posistemės vėlinimams išmatuoti. Atlikus eksperimentinius naudojamos sistemos tyrimus išmatuotos visos vėlinimo dedamosios ir apskaičiuotas bendras žvilgsnio sekimo įrangos vėlinimas – 28 ms ir vidutinis bendras kompiuterio grafinės posistemės ir vaizduoklio vėlinimas – 9,5 ms.
Vilnius Gediminas Technical University
Title: ELIMINATION OF DELAYS TO OCULOMOTOR RESEARCH EQUIPMENT / OKULOMOTORINIŲ TYRIMŲ ĮRANGOS VĖLINIMO ELIMINAVIMAS
Description:
Optic stimulus used for human oculomotor system or eye-hand coordination researches is often represented on a computer screen.
They must be synchronised with the eye tracker to achieve the accurate results of the conducted experiments.
Relation between stimulus presence and eye image capturing times can be defined only with reference to knowledge of all system delays.
The suggested research evaluates our eye tracking system delay and propose a practical method for measuring and evaluating delays to the computer graphic subsystem.
Experimental research shows that LC Technologies eye tracker reports gaze angle with 28 ms lag and the average stimulus lag of the computer graphic subsystem is 9,5 ms.
Santrauka
Atliekant žmogaus okulomotorinės sistemos ar akies ir rankos koordinacijos tyrimus, naudojami optiniai stimulai, kurie atvaizduojami kompiuterio vaizduoklyje.
Norint gauti tikslius tyrimų rezultatus, reikalinga šių stimulų sinchronizacija su žvilgsnio krypties registravimo įranga.
Stimulo pasirodymo ir akies vaizdo užfiksavimo laikus sutapdinti galima tik įvertinus visas sistemos vėlinimo dedamąsias.
Darbe apskaičiuotas naudojamos akių judesių registravimo įrangos vėlinimas ir pasiūlytas praktinis metodas kompiuterio grafinės posistemės vėlinimams išmatuoti.
Atlikus eksperimentinius naudojamos sistemos tyrimus išmatuotos visos vėlinimo dedamosios ir apskaičiuotas bendras žvilgsnio sekimo įrangos vėlinimas – 28 ms ir vidutinis bendras kompiuterio grafinės posistemės ir vaizduoklio vėlinimas – 9,5 ms.
Related Results
Upper basilar artery aneurysms: oculomotor outcomes in 163 cases
Upper basilar artery aneurysms: oculomotor outcomes in 163 cases
Object. The purpose of this study was to identify factors predictive of postoperative oculomotor nerve palsy among patients who undergo surgery for distal basilar artery (BA) aneur...
Saliency-Driven Oculomotor Control
Saliency-Driven Oculomotor Control
The research presented in this thesis unravels the effects of distractors on saliency-driven oculomotor control through a multidisciplinary approach using eye tracking and electrop...
Methods for chair restraint and training of the common marmoset on oculomotor tasks
Methods for chair restraint and training of the common marmoset on oculomotor tasks
ABSTRACT
The oculomotor system is the most thoroughly understood sensorimotor system in the brain, due in large part to electrophysiological stud...
Factors predicting treatment delays in endometrial cancer
Factors predicting treatment delays in endometrial cancer
Background: Women diagnosed with type I endometrial cancer have a favorable prognosis and are often cured with surgery alone when treated in a timely manner at an early stage. Howe...
Factors affecting delays in seeking treatment among malaria patients in the post-elimination phase in China
Factors affecting delays in seeking treatment among malaria patients in the post-elimination phase in China
Abstract
Background
Delays in malaria treatment can not only lead to severe and even life-threatening complications, but can also be a source of malaria re-transmission, pu...
Visual motion processing in visual motion hypersensitivity patients ensuing from mild traumatic brain injury
Visual motion processing in visual motion hypersensitivity patients ensuing from mild traumatic brain injury
<p dir="ltr">Mild traumatic brain injury (mTBI) represents a pervasive public health issue, precipitating a range of persistent post-concussion symptoms (PCS) in up to 82% of...
Visual motion processing in visual motion hypersensitivity patients ensuing from mild traumatic brain injury
Visual motion processing in visual motion hypersensitivity patients ensuing from mild traumatic brain injury
<p dir="ltr">Mild traumatic brain injury (mTBI) represents a pervasive public health issue, precipitating a range of persistent post-concussion symptoms (PCS) in up to 82% of...
Attention capture outside the oculomotor range
Attention capture outside the oculomotor range
ABSTRACT
Neurophysiological studies demonstrated that attentional orienting is performed by fronto-parietal brain areas which also play an important role in oculomo...

