Javascript must be enabled to continue!
MECHANICAL ANALYSIS OF ORTHODONTIC WIRES
View through CrossRef
Orthodontic tooth movement is a physiologic response to externally applied forces; the motive forces are primarily mechanical. The optimal application of orthodontic force enables maximum movement of teeth with minimal irreversible damage of the periodontal ligament (PDL), alveolar bone, and teeth. Since arch wires are the main force system in orthodontics, it is important in clinical practice that they deliver appropriate, predictable and repeatable forces during treatment. These specialized wires even promise shape memory properties and the possibility of super elastic behavior, which significantly impacts clinical practices. Since, standard stainless steel and titanium arch wires are still the materials of choice in many stages of treatment. They provide an attractive combination of stiffness, resilience and formability. However, clinical practitioners have commented on the variability of arch wire behavior for years. Inconsistent arch wire properties can contribute to unpredictable treatment duration and results. This paper examines the mechanical and physical characteristics of stainless steel and titanium wires to quantify their variability in engineering terms. From the results for both types of wires, the testing method provides the information required by designers wishing to improve the arch wire properties and provide valuable information to clinicians for their practice.
University of Diyala, College of Science
Title: MECHANICAL ANALYSIS OF ORTHODONTIC WIRES
Description:
Orthodontic tooth movement is a physiologic response to externally applied forces; the motive forces are primarily mechanical.
The optimal application of orthodontic force enables maximum movement of teeth with minimal irreversible damage of the periodontal ligament (PDL), alveolar bone, and teeth.
Since arch wires are the main force system in orthodontics, it is important in clinical practice that they deliver appropriate, predictable and repeatable forces during treatment.
These specialized wires even promise shape memory properties and the possibility of super elastic behavior, which significantly impacts clinical practices.
Since, standard stainless steel and titanium arch wires are still the materials of choice in many stages of treatment.
They provide an attractive combination of stiffness, resilience and formability.
However, clinical practitioners have commented on the variability of arch wire behavior for years.
Inconsistent arch wire properties can contribute to unpredictable treatment duration and results.
This paper examines the mechanical and physical characteristics of stainless steel and titanium wires to quantify their variability in engineering terms.
From the results for both types of wires, the testing method provides the information required by designers wishing to improve the arch wire properties and provide valuable information to clinicians for their practice.
Related Results
Perception of Dental Caries Risk and Prevention among Orthodontic Patients – A Cross-Sectional Survey
Perception of Dental Caries Risk and Prevention among Orthodontic Patients – A Cross-Sectional Survey
Aim: To investigate the perception of dental caries risk and prevention among patients undergoing orthodontic treatment and to assess the influence of the oral hygiene information ...
CD301b+ macrophages: a new target for improving the efficiency of orthodontic treatment under mild inflammation
CD301b+ macrophages: a new target for improving the efficiency of orthodontic treatment under mild inflammation
Abstract
With improvements in the quality of life and the demand for aesthetics, more and more people are opting for orthodontic treatment, resulting in a surge in adult or...
Quantitative and qualitative analyses of orthodontic-related videos on YouTube
Quantitative and qualitative analyses of orthodontic-related videos on YouTube
ABSTRACT
Objectives
To investigate content of orthodontic-related videos on YouTube to improve the understanding of orthodontic ...
Is orthodontic research falling prey to obscure and predatory journals? A bibliometric study
Is orthodontic research falling prey to obscure and predatory journals? A bibliometric study
Abstract
Aims
To evaluate where orthodontic research papers are published and to explore potential relationships between the jou...
Accuracy Evaluation of Indirect Bonding Techniques for Clear Aligner Attachments Using 3D-Printed Models: An In Silico and Physical Model-Based Study
Accuracy Evaluation of Indirect Bonding Techniques for Clear Aligner Attachments Using 3D-Printed Models: An In Silico and Physical Model-Based Study
An inaccurate bonding procedure of the attachments related to clear aligner systems could influence the predictability of tooth movement The aim of this study was to compare the po...
A study of forces originating from orthodontic appliances for splinting of teeth
A study of forces originating from orthodontic appliances for splinting of teeth
Abstract Management of dental trauma in children sometimes requires the use of a dental splint. This can be constructed with composite materials, kevlar, fiberglass, wire and compo...
Orthodontic approach in dental trauma: systematic review and meta-analysis
Orthodontic approach in dental trauma: systematic review and meta-analysis
Introduction: There is a high prevalence of dental trauma in patients in need of orthodontic treatment, so it is important the knowledge about the orthodontic approach in cases of ...
MALDI-TOF Analysis of K-wire Biofilms: A Pilot Study
MALDI-TOF Analysis of K-wire Biofilms: A Pilot Study
Category: Basic Sciences/Biologics Introduction/Purpose: In orthopedic foot and ankle surgery, temporary fixation utilizing percutaneous Kirschner wires (K- wires) is required for ...

