Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Accuracy comparison of various quantitative [99mTc]Tc-DPD SPECT/CT reconstruction techniques in patients with symptomatic hip and knee joint prostheses

View through CrossRef
Abstract Background There is a need for better diagnostic tools that identify loose total hip and knee arthroplasties. Here, we present the accuracy of different 99mTc-dicarboxypropandiphosphate ([99mTc]Tc-DPD) SPECT/CT quantification tools for the detection of loose prostheses in patients with painful hip and knee arthroplasties. Methods Quantitative reconstruction of mineral phase SPECT data was performed using Siemens xSPECT-Quant and xSPECT-Bone, with and without metal artefact reduction (iMAR) of CT-data. Quantitative data (SUVmax values) were compared to intraoperative diagnosis or clinical outcome after at least 1 year as standard of comparison. Cut-off values and accuracies were calculated using receiver operator characteristics. Accuracy of uptake quantification was compared to the accuracy of visual SPECT/CT readings, blinded for the quantitative data and clinical outcome. Results In this prospective study, 30 consecutive patients with 33 symptomatic hip and knee prostheses underwent [99mTc]Tc-DPD SPECT/CT. Ten arthroplasties were diagnosed loose and 23 stable. Mean-SUVmax was significantly higher around loose prostheses compared to stable prostheses, regardless of the quantification method (P = 0.0025–0.0001). Quantification with xSPECT-Bone-iMAR showed the highest accuracy (93.9% [95% CI 79.6–100%]) which was significantly higher compared to xSPECT-Quant-iMAR (81.8% [67.5–96.1%], P = 0.04) and xSPECT-Quant without iMAR (77.4% [62.4–92.4%], P = 0.02). Accuracies of clinical reading were non-significantly lower compared to quantitative measures (84.8% [70.6–99.1%] (senior) and 81.5% [67.5–96.1%] (trainee)). Conclusion Quantification with [99mTc]Tc-DPD xSPECT-Bone-iMAR discriminates best between loose and stable prostheses of all evaluated methods. The overall high accuracy of different quantitative measures underlines the potential of [99mTc]Tc-DPD-quantification as a biomarker and demands further prospective evaluation in a larger number of prosthesis.
Title: Accuracy comparison of various quantitative [99mTc]Tc-DPD SPECT/CT reconstruction techniques in patients with symptomatic hip and knee joint prostheses
Description:
Abstract Background There is a need for better diagnostic tools that identify loose total hip and knee arthroplasties.
Here, we present the accuracy of different 99mTc-dicarboxypropandiphosphate ([99mTc]Tc-DPD) SPECT/CT quantification tools for the detection of loose prostheses in patients with painful hip and knee arthroplasties.
Methods Quantitative reconstruction of mineral phase SPECT data was performed using Siemens xSPECT-Quant and xSPECT-Bone, with and without metal artefact reduction (iMAR) of CT-data.
Quantitative data (SUVmax values) were compared to intraoperative diagnosis or clinical outcome after at least 1 year as standard of comparison.
Cut-off values and accuracies were calculated using receiver operator characteristics.
Accuracy of uptake quantification was compared to the accuracy of visual SPECT/CT readings, blinded for the quantitative data and clinical outcome.
Results In this prospective study, 30 consecutive patients with 33 symptomatic hip and knee prostheses underwent [99mTc]Tc-DPD SPECT/CT.
Ten arthroplasties were diagnosed loose and 23 stable.
Mean-SUVmax was significantly higher around loose prostheses compared to stable prostheses, regardless of the quantification method (P = 0.
0025–0.
0001).
Quantification with xSPECT-Bone-iMAR showed the highest accuracy (93.
9% [95% CI 79.
6–100%]) which was significantly higher compared to xSPECT-Quant-iMAR (81.
8% [67.
5–96.
1%], P = 0.
04) and xSPECT-Quant without iMAR (77.
4% [62.
4–92.
4%], P = 0.
02).
Accuracies of clinical reading were non-significantly lower compared to quantitative measures (84.
8% [70.
6–99.
1%] (senior) and 81.
5% [67.
5–96.
1%] (trainee)).
Conclusion Quantification with [99mTc]Tc-DPD xSPECT-Bone-iMAR discriminates best between loose and stable prostheses of all evaluated methods.
The overall high accuracy of different quantitative measures underlines the potential of [99mTc]Tc-DPD-quantification as a biomarker and demands further prospective evaluation in a larger number of prosthesis.

Related Results

Non-Invasive Mycobacterium avium Detection Using 99mTc-GSA on Single-Photon Emission Computed Tomography
Non-Invasive Mycobacterium avium Detection Using 99mTc-GSA on Single-Photon Emission Computed Tomography
Background: The prevalence of nontuberculous mycobacteria (NTM) infection is on the rise, surpassing that of pulmonary tuberculosis in Japan. Current standard therapy for NTM infec...
Absolute quantification in brain SPECT imaging
Absolute quantification in brain SPECT imaging
Certes malalties neurològiques estan associades amb problemes en els sistemes de neurotransmissió. Una aproximació a l'estudi d'aquests sistemes és la tomografia d'emissió SPECT (S...
Comparative Kinetics of Microvascular Inulin and 99mTc-Labelled Diethylenetriaminepenta-Acetic Acid Exchange
Comparative Kinetics of Microvascular Inulin and 99mTc-Labelled Diethylenetriaminepenta-Acetic Acid Exchange
1. After simultaneous intravenous injection as a mixture, 99mTc-labelled diethylenetriaminepentaacetic acid (99mTc-DTPA; molecular mass 492 Da) and inulin (∼6000 Da) gave arterial ...
Assessment of Cardiac Amyloidosis with 99mTc-Pyrophosphate (PYP) Quantitative SPECT
Assessment of Cardiac Amyloidosis with 99mTc-Pyrophosphate (PYP) Quantitative SPECT
Abstract Background: 99mTc-PYP scintigraphy provides differential diagnosis of ATTR cardiomyopathy (ATTR-CM) from light chain cardiac amyloidosis and other myocardial disor...
Assessment of Cardiac Amyloidosis with 99mTc-Pyrophosphate (PYP) Quantitative SPECT
Assessment of Cardiac Amyloidosis with 99mTc-Pyrophosphate (PYP) Quantitative SPECT
Abstract Background: 99mTc-PYP scintigraphy provides differential diagnosis of ATTR cardiomyopathy (ATTR-CM) from light chain cardiac amyloidosis and other myocardial disor...
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
This paper explores South African hip-hop activist Emile YX?'s work to suggest that he presents an alternative take on mainstream US and South African hip-hop. While it is arguable...
Baseline bone mineral density and bone turnover in pre-operative hip and knee arthroplasty patients
Baseline bone mineral density and bone turnover in pre-operative hip and knee arthroplasty patients
Aims Osteoporosis and abnormal bone metabolism may prove to be significant factors influencing the outcome of arthroplasty surgery, predisposing to complications of aseptic looseni...
Indeterminate solitary vertebral lesions on planar scintigraphy
Indeterminate solitary vertebral lesions on planar scintigraphy
Summary Objective: This study aims to evaluate the added value of hybrid SPECT-CT in differential diagnosis of indeterminate solitary vertebral lesion (SVL) on planar sci...

Back to Top