Javascript must be enabled to continue!
Adsorptive Cathodic Stripping Voltammetry for Quantification of Alprazolam
View through CrossRef
A simple and highly sensitive electrochemical sensor was developed for adsorptive cathodic stripping voltammetry of alprazolam. Based on an electrochemically pretreated glassy carbon electrode, the sensor demonstrated good adsorption and electrochemical reduction of alprazolam. The morphology of the glassy carbon electrode and the electrochemically pretreated glassy carbon electrode were characterized by scanning electron microscopy/energy dispersive X-ray spectroscopy, Fourier transform infrared spectroscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. The electrochemical behaviors of alprazolam were determined by cyclic voltammetry, and the analytical measurements were studied by adsorptive cathodic stripping voltammetry. Optimized operational conditions included the concentration and deposition time of sulfuric acid in the electrochemical pretreatment, preconcentration potential, and preconcentration time. Under optimal conditions, the developed alprazolam sensor displayed a quantification limit of 0.1 mg L−1, a detection limit of 0.03 mg L−1, a sensitivity of 67 µA mg−1 L cm−2 and two linear ranges: 0.1 to 4 and 4 to 20 mg L−1. Sensor selectivity was excellent, and repeatability (%RSD < 4.24%) and recovery (82.0 ± 0.2 to 109.0 ± 0.3%) were good. The results of determining alprazolam in beverages with the developed system were in good agreement with results from the gas chromatography–mass spectrometric method.
Title: Adsorptive Cathodic Stripping Voltammetry for Quantification of Alprazolam
Description:
A simple and highly sensitive electrochemical sensor was developed for adsorptive cathodic stripping voltammetry of alprazolam.
Based on an electrochemically pretreated glassy carbon electrode, the sensor demonstrated good adsorption and electrochemical reduction of alprazolam.
The morphology of the glassy carbon electrode and the electrochemically pretreated glassy carbon electrode were characterized by scanning electron microscopy/energy dispersive X-ray spectroscopy, Fourier transform infrared spectroscopy, cyclic voltammetry, and electrochemical impedance spectroscopy.
The electrochemical behaviors of alprazolam were determined by cyclic voltammetry, and the analytical measurements were studied by adsorptive cathodic stripping voltammetry.
Optimized operational conditions included the concentration and deposition time of sulfuric acid in the electrochemical pretreatment, preconcentration potential, and preconcentration time.
Under optimal conditions, the developed alprazolam sensor displayed a quantification limit of 0.
1 mg L−1, a detection limit of 0.
03 mg L−1, a sensitivity of 67 µA mg−1 L cm−2 and two linear ranges: 0.
1 to 4 and 4 to 20 mg L−1.
Sensor selectivity was excellent, and repeatability (%RSD < 4.
24%) and recovery (82.
0 ± 0.
2 to 109.
0 ± 0.
3%) were good.
The results of determining alprazolam in beverages with the developed system were in good agreement with results from the gas chromatography–mass spectrometric method.
Related Results
Efficacy and safety of alprazolam, imipramine and placebo in treating panic disorder. A Scandinavian multicenter study
Efficacy and safety of alprazolam, imipramine and placebo in treating panic disorder. A Scandinavian multicenter study
As part of the cross‐national collaborative panic study, a double‐blind comparison of alprazolam, imipramine and placebo was performed in Scandinavian outpatients with panic disord...
Effect of alprazolam on rat serum metabolic profiles
Effect of alprazolam on rat serum metabolic profiles
AbstractWe developed a serum metabolomic method by gas chromatography–mass spectrometry (GC–MS) to evaluate the effect of alprazolam in rats. The GC–MS with HP‐5MS (0.25 μm × 30 m ...
Cathodic stripping voltammetric measurements of cholesterol following adsorptive preconcentration at the static mercury drop electrode
Cathodic stripping voltammetric measurements of cholesterol following adsorptive preconcentration at the static mercury drop electrode
AbstractA new electrochemical method for direct measurement of cholesterol by cathodic stripping voltammetry is presented. The method is based on controlled adsorptive preconcentra...
Cathodic Protection Monitoring-Bullwinkle
Cathodic Protection Monitoring-Bullwinkle
ABSTRACT
The Bullwinkle Platform represents a major advance in the drilling and production of oil and gas, but also in cathodic protection design for deep ocean e...
Preparation of Silver-Based Mercury Film Electrodes for Anodic Stripping Voltammetry
Preparation of Silver-Based Mercury Film Electrodes for Anodic Stripping Voltammetry
The aim of this study was to develop an electrochemical method for reproducible preparation and evaluation of silver-based mercury film electrodes (SBMFE) for applications such as ...
Cathodic Protection for Parking Structures
Cathodic Protection for Parking Structures
Cathodic protection systems for chloride-contaminated reinforced concrete structures have been installed and evaluated since the early 1970s. Until recently, most of these systems ...
SCADA Based Pipelines Cathodic Protection Systems Remote Monitoring Project
SCADA Based Pipelines Cathodic Protection Systems Remote Monitoring Project
Abstract
This paper presents a remote monitoring system for pipeline cathodic protection using Supervisory Control and Data Acquisition (SCADA) technology, aimed at ...
To evaluate the outcome of varicose vein surgery with and without venous stripping
To evaluate the outcome of varicose vein surgery with and without venous stripping
Aim: The aim of this study to evaluate the outcome of varicose vein surgery with and without venous stripping.Material and methods: This research covered 100 varicose vein operatio...

