Apnea detection is critical to the management of infant apnea. Effective monitoring and management of apnea using apnea monitors is known to reduce complications and possible fatalities in infants. There is a need to determine the critical design considerations in apnea monitors. This article reviews the design and development of infant apnea monitors. We conducted a targeted literature review from different databases, including PubMed, ScienceDirect, and Google Scholar. We reviewed articles published between January 1995 and February 2023. The search was done using combinations of key terms, namely, “apnea,” “apnea monitors,” and “apnea monitor design.” Articles that met the inclusion criteria were extracted and analyzed. The review investigated common physiological parameters, sensor types, and validation results of apnea monitors. The review revealed important design considerations adopted in the literature as well as the different sensor types and methods of apnea detection. It was found that thoracic impedance pneumography, thermistors, respiratory inductance plethysmography, pneumotachograph, and MEMS accelerometer are the most common sensor types used to design apnea monitors. The review revealed that most apnea monitors were designed to measure multiple physiological parameters. Device validation results varied from one device to another, with sensitivity and specificity metrics ranging between 80% and 96%. With the high burden of infant apnea in developing countries and its associated mortality and morbidity, the design of functional infant apnea monitors has become increasingly important to complement the expensive and complex polysomnography technique. Therefore, we must use appropriate sensors and design approaches for effective detection of infant apnea.
Ovid Technologies (Wolters Kluwer Health)
Title: A review of infant apnea monitor design
Description:
Apnea detection is critical to the management of infant apnea.
Effective monitoring and management of apnea using apnea monitors is known to reduce complications and possible fatalities in infants.
There is a need to determine the critical design considerations in apnea monitors.
This article reviews the design and development of infant apnea monitors.
We conducted a targeted literature review from different databases, including PubMed, ScienceDirect, and Google Scholar.
We reviewed articles published between January 1995 and February 2023.
The search was done using combinations of key terms, namely, “apnea,” “apnea monitors,” and “apnea monitor design.
” Articles that met the inclusion criteria were extracted and analyzed.
The review investigated common physiological parameters, sensor types, and validation results of apnea monitors.
The review revealed important design considerations adopted in the literature as well as the different sensor types and methods of apnea detection.
It was found that thoracic impedance pneumography, thermistors, respiratory inductance plethysmography, pneumotachograph, and MEMS accelerometer are the most common sensor types used to design apnea monitors.
The review revealed that most apnea monitors were designed to measure multiple physiological parameters.
Device validation results varied from one device to another, with sensitivity and specificity metrics ranging between 80% and 96%.
With the high burden of infant apnea in developing countries and its associated mortality and morbidity, the design of functional infant apnea monitors has become increasingly important to complement the expensive and complex polysomnography technique.
Therefore, we must use appropriate sensors and design approaches for effective detection of infant apnea.
Related Results
0864 Severe Central Sleep Apnea
0864 Severe Central Sleep Apnea
Abstract
Introduction
Central sleep apnea (CSA) is a rare form of sleep disordered breathing with repeated apneic episodes with ...
1027 Valproic Acid and Central Sleep Apnea: A Retrospective Study
1027 Valproic Acid and Central Sleep Apnea: A Retrospective Study
Abstract
Introduction
Central sleep apnea (CSA) is associated with several medical conditions (e.g., heart failure, atrial fibri...
Sleep Apnea: Detection and Classification of Infant Patterns
Sleep Apnea: Detection and Classification of Infant Patterns
Abstract
Apnea is defined as a period in which an infant stops breathing. When the apnea period is greater than a critical period, serious damage in the infant's brain ma...
Changes in PUFA and eicosanoid metabolism during/after apnea diving: a prospective single-center study
Changes in PUFA and eicosanoid metabolism during/after apnea diving: a prospective single-center study
Background: The popularity of apneic diving is continually growing. As apnea diving substantially burdens the cardiovascular system, special focus is warranted. Regarding inflammat...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract
The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
High prevalence of obstructive sleep apnea in Marfan's syndrome
High prevalence of obstructive sleep apnea in Marfan's syndrome
Objective
To review the current evidence about the prevalence of obstructive sleep apnea in patients with Marfan's syndrome, and discuss some proposed potential mechani...
From ‘baby-farmer’, to ‘licensee’, to ‘foster-parent’: the origin and administration of New Zealand’s Infant Life Protection legislation, 1893–1926
From ‘baby-farmer’, to ‘licensee’, to ‘foster-parent’: the origin and administration of New Zealand’s Infant Life Protection legislation, 1893–1926
<p><strong>New Zealand’s efforts to regulate ‘baby-farming’ – the practice of taking in an infant or young child in exchange for payment – led to several pieces of legi...