Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Retinal Optical Quality of Multifocal Refractive and Monofocal Intraocular Lenses

View through CrossRef
(1) Background: This study aimed to evaluate and compare the clinical optical image quality following implantation with different premium IOLs by the analysis of the point spread function (PSF) Strehl ratio using a Pyramidal WaveFront-based sensor (PWS) aberrometer at two different pupil sizes. (2) Methods: This study included 96 eyes of 70 patients implanted with: (1) 19 AcrySof SA60AT (control group); (2) 24 LENTIS Mplus LS-313 MF30; (3) 33 LENTIS Mplus LS-313 MF15; and (4) 20 Precizon Presbyopic. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root-mean-square (RMS), and low- and high-order aberrations’ RMS measured by PWS aberrometer. Results: SA60AT had the highest significant PSFw2 Strehl ratio at both 3- and 4-mm pupil size (0.41 ± 0.11 and 0.28 ± 0.07) followed by LENTIS Mplus 15 (group C, 0.35 ± 0.1 and 0.21 ± 0.06) and a near tie between LENTIS MPLUS 30 (group B, 0.27 ± 0.08 and 0.18 ± 0.06) and Precizon Presbyopic (group D, 0.27 ± 0.07 and 0.17 ± 0.04). MPlus MF15 was found to be significantly better than MPlus MF30 at both 3.00 mm (p < 0.0001) and 4.00 mm (p = 0.002). (4) Conclusions: The PSFw2 represents a new tool to objectively evaluate the far distance retinal image quality of multifocal IOLs, and the far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens.
Title: Retinal Optical Quality of Multifocal Refractive and Monofocal Intraocular Lenses
Description:
(1) Background: This study aimed to evaluate and compare the clinical optical image quality following implantation with different premium IOLs by the analysis of the point spread function (PSF) Strehl ratio using a Pyramidal WaveFront-based sensor (PWS) aberrometer at two different pupil sizes.
(2) Methods: This study included 96 eyes of 70 patients implanted with: (1) 19 AcrySof SA60AT (control group); (2) 24 LENTIS Mplus LS-313 MF30; (3) 33 LENTIS Mplus LS-313 MF15; and (4) 20 Precizon Presbyopic.
Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root-mean-square (RMS), and low- and high-order aberrations’ RMS measured by PWS aberrometer.
Results: SA60AT had the highest significant PSFw2 Strehl ratio at both 3- and 4-mm pupil size (0.
41 ± 0.
11 and 0.
28 ± 0.
07) followed by LENTIS Mplus 15 (group C, 0.
35 ± 0.
1 and 0.
21 ± 0.
06) and a near tie between LENTIS MPLUS 30 (group B, 0.
27 ± 0.
08 and 0.
18 ± 0.
06) and Precizon Presbyopic (group D, 0.
27 ± 0.
07 and 0.
17 ± 0.
04).
MPlus MF15 was found to be significantly better than MPlus MF30 at both 3.
00 mm (p < 0.
0001) and 4.
00 mm (p = 0.
002).
(4) Conclusions: The PSFw2 represents a new tool to objectively evaluate the far distance retinal image quality of multifocal IOLs, and the far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens.

Related Results

Intraocular correction of presbyopia after laser keratorefractive surgery
Intraocular correction of presbyopia after laser keratorefractive surgery
Purpose. To present the results of research on modern aspects of intraocular correction of presbyopia after laser keratorefractive surgery. Material and methods. A literature ...
Retinal Oximetry
Retinal Oximetry
Abstract.Purpose:Malfunction of retinal blood flow or oxygenation is believed to be involved in various diseases. Among them are retinal vessel occlusions, diabetic retinopathy and...
Intraocular lens models: Ecological distribution footprint and usage trends at a large ophthalmology centre
Intraocular lens models: Ecological distribution footprint and usage trends at a large ophthalmology centre
Abstract Background Operating theatres significantly contribute to hospital’s environmental footprint, underscoring the need to evaluate the ecol...
Técnicas de reconstrucción y compensación activa de frentes de onda complejos
Técnicas de reconstrucción y compensación activa de frentes de onda complejos
The continuous improvements of optical design tools and manufacturing technologies of free-form optical elements, allow the creation of new complex-shaped lenses that improve the p...
Intraocular Fluid Analysis-Guided Precision Therapy in the Treatment of Acute Retinal Necrosis Syndrome
Intraocular Fluid Analysis-Guided Precision Therapy in the Treatment of Acute Retinal Necrosis Syndrome
Abstract Objective: To explore the role of intraocular fluid testing in the treatment and prognostic assessment of Acute Retinal Necrosis Syndrome (ARNs), providing a basis...
Factors Affecting Near Vision After Monofocal Intraocular Lens Implantation
Factors Affecting Near Vision After Monofocal Intraocular Lens Implantation
PURPOSE: To identify factors that influence near vision after monofocal intraocular lens (IOL) implantation for distance vision. METHO...

Back to Top