Javascript must be enabled to continue!
An Intracortical Microprobe with Adaptive Stiffness
View through CrossRef
Abstract
Utilising a flexible intracortical microprobe to record/stimulate neurons minimises the incompatibility between the implanted microprobe and the brain, reducing tissue damage due to the brain micromotion. Applying bio-dissolvable coating materials temporarily makes a flexible microprobe stiff to tolerate the penetration force during insertion. However, the inability to adjust the dissolving time after the microprobe contact with the cerebrospinal fluid may lead to inaccuracy in the microprobe positioning. Furthermore, since the dissolving process is irreversible, any subsequent positioning error cannot be corrected by re-stiffening the microprobe. This study proposes a compliant intracortical microprobe whose equivalent elastic modulus increases because of the axial force applied by an inserter. Thus, instant switching between stiff and soft modes can be accomplished as many times as necessary to ensure high-accuracy positioning while causing minimal tissue damage. The equivalent elastic modulus of the microprobe during operation is ≈ 23 kPa, which is ≈ 42% less than the existing counterpart, resulting in ≈ 46% less maximum strain generated on the surrounding tissue under brain longitudinal motion. The microprobe with adaptive stiffness and surrounding neural tissue are simulated during insertion and operation to confirm the efficiency of the design. Two-photon polymerisation technology is utilised to 3D print the proposed microprobe, which is inserted into a lamb’s brain without buckling.
Title: An Intracortical Microprobe with Adaptive Stiffness
Description:
Abstract
Utilising a flexible intracortical microprobe to record/stimulate neurons minimises the incompatibility between the implanted microprobe and the brain, reducing tissue damage due to the brain micromotion.
Applying bio-dissolvable coating materials temporarily makes a flexible microprobe stiff to tolerate the penetration force during insertion.
However, the inability to adjust the dissolving time after the microprobe contact with the cerebrospinal fluid may lead to inaccuracy in the microprobe positioning.
Furthermore, since the dissolving process is irreversible, any subsequent positioning error cannot be corrected by re-stiffening the microprobe.
This study proposes a compliant intracortical microprobe whose equivalent elastic modulus increases because of the axial force applied by an inserter.
Thus, instant switching between stiff and soft modes can be accomplished as many times as necessary to ensure high-accuracy positioning while causing minimal tissue damage.
The equivalent elastic modulus of the microprobe during operation is ≈ 23 kPa, which is ≈ 42% less than the existing counterpart, resulting in ≈ 46% less maximum strain generated on the surrounding tissue under brain longitudinal motion.
The microprobe with adaptive stiffness and surrounding neural tissue are simulated during insertion and operation to confirm the efficiency of the design.
Two-photon polymerisation technology is utilised to 3D print the proposed microprobe, which is inserted into a lamb’s brain without buckling.
Related Results
Spleen and Liver Fibrosis Is Associated to Treatment Response and Prognosis in Philadelphia-Negative Chronic Myeloproliferative Neoplasms
Spleen and Liver Fibrosis Is Associated to Treatment Response and Prognosis in Philadelphia-Negative Chronic Myeloproliferative Neoplasms
Abstract
Introduction: Spleen and liver stiffness, investigated by transient elastography (TE), have been associated with marrow fibrosis in patients...
Stiffness regulation by reflex action in the normal human hand
Stiffness regulation by reflex action in the normal human hand
1. The torque and electromyographic (EMG) responses to stretch of the first dorsal interosseous muscle (externally imposed joint rotation) were recorded in five normal human subjec...
Abstract 1099: Mapping matrix mechanics in 3D to study the role of stiffness in breast tumor progression.
Abstract 1099: Mapping matrix mechanics in 3D to study the role of stiffness in breast tumor progression.
Abstract
Introduction
Evidence suggests that the Extra Cellular Matrix (ECM) stiffness may be a driving factor in tumor progression and may sensitize ...
Analysis of tooth stiffness of nutation face gear
Analysis of tooth stiffness of nutation face gear
Purpose
The purpose of this paper is to obtain the single-tooth stiffness, single-tooth time-varying meshing stiffness and comprehensive meshing stiffness of th...
Arterial Stiffness Assessed by Cardio-Ankle Vascular Index
Arterial Stiffness Assessed by Cardio-Ankle Vascular Index
Arterial stiffness is an age-related disorder. In the medial layer of arteries, mechanical fracture due to fatigue failure for the pulsatile wall strain causes medial degeneration ...
Comprehensive stiffness analysis of the cylindrical roller bearing for aircraft engines considering the radial clearance
Comprehensive stiffness analysis of the cylindrical roller bearing for aircraft engines considering the radial clearance
Purpose
The rotor system supported by the cylindrical roller bearings is widely used in various fields such as aviation, space and machinery due to its importance. In the study of ...
Prevention and treatment of excessive arterial stiffness
Prevention and treatment of excessive arterial stiffness
Abstract
Arterial stiffness affecting mainly the aorta and its large branches is currently the subject of numerous studies. Over the years, such arterial stiffnes...
The Role of Muscle Stiffness in Different Stepping Directions and Its
Aging-Related Changes: Preliminary Data
The Role of Muscle Stiffness in Different Stepping Directions and Its
Aging-Related Changes: Preliminary Data
Background & Aim: Stepping is one of the most common reactions to
avoid falls in the older population. Thus, researchers have made efforts to
...