Javascript must be enabled to continue!
Evaluation of the Abdominal Aorta and External Iliac Arteries Using Three-Dimensional Time-of-Flight, Three Dimensional Electrocardiograph-Gated Fast Spin-Echo, and Contrast-Enhanced Magnetic Resonance Angiography in Clinically Healthy Cats
View through CrossRef
Arterial thromboembolism is associated with high morbidity and mortality rates in cats. Definitive diagnosis requires advanced imaging modalities, such as computed tomography angiography (CTA) and contrast-enhanced (CE) magnetic resonance angiography (MRA). However, CTA involves exposure to a large amount of ionized radiation, and CE-MRA can cause systemic nephrogenic fibrosis. Non-contrast-enhanced (NE) MRA can help accurately diagnose vascular lesions without such limitations. In this study, we evaluated the ability of NE-MRA using three-dimensional electrocardiograph-gated fast spin-echo (3D ECG-FSE) and 3D time-of-flight (3D TOF) imaging to visualize the aorta and external iliac arteries in clinically healthy cats and compared the results with those obtained using CE-MRA. All 11 cats underwent 3D ECG-FSE, 3D TOF, and CE-MRA sequences. Relative signal intensity (rSI) for quantitative image analysis and image quality scores (IQS) for qualitative image analysis were assessed; the rSI values based on the 3D TOF evaluations were significantly lower than those obtained using 3D ECG-FSE (aorta 3D TOF: 0.57 ± 0.06, aorta 3D ECG-FSE: 0.83 ± 0.06, P < 0.001; external iliac arteries 3D TOF: 0.45 ± 0.06, external iliac arteries 3D ECG-FSE:0.80 ± 0.05, P < 0.001) and similar to those obtained using CE-MRA (aorta: 0.58 ± 0.05, external iliac arteries: 0.57 ± 0.03). Moreover, IQS obtained using 3D TOF were significantly higher than those obtained using 3D ECG-FSE (aorta 3D TOF: 3.95 ± 0.15, aorta 3D ECG-FSE: 2.32 ± 0.60, P < 0.001; external iliac arteries 3D ECG-FSE: 3.98 ± 0.08, external iliac arteries 3D ECG-FSE: 2.23 ± 0.56, P < 0.001) and similar to those obtained using CE-MRA (aorta: 3.61 ± 0.41, external iliac arteries: 3.57 ± 0.41). Thus, 3D TOF is more suitable and produces consistent image quality for visualizing the aorta and external iliac arteries in clinically healthy cats and this will be of great help in the diagnosis of FATE.
Title: Evaluation of the Abdominal Aorta and External Iliac Arteries Using Three-Dimensional Time-of-Flight, Three Dimensional Electrocardiograph-Gated Fast Spin-Echo, and Contrast-Enhanced Magnetic Resonance Angiography in Clinically Healthy Cats
Description:
Arterial thromboembolism is associated with high morbidity and mortality rates in cats.
Definitive diagnosis requires advanced imaging modalities, such as computed tomography angiography (CTA) and contrast-enhanced (CE) magnetic resonance angiography (MRA).
However, CTA involves exposure to a large amount of ionized radiation, and CE-MRA can cause systemic nephrogenic fibrosis.
Non-contrast-enhanced (NE) MRA can help accurately diagnose vascular lesions without such limitations.
In this study, we evaluated the ability of NE-MRA using three-dimensional electrocardiograph-gated fast spin-echo (3D ECG-FSE) and 3D time-of-flight (3D TOF) imaging to visualize the aorta and external iliac arteries in clinically healthy cats and compared the results with those obtained using CE-MRA.
All 11 cats underwent 3D ECG-FSE, 3D TOF, and CE-MRA sequences.
Relative signal intensity (rSI) for quantitative image analysis and image quality scores (IQS) for qualitative image analysis were assessed; the rSI values based on the 3D TOF evaluations were significantly lower than those obtained using 3D ECG-FSE (aorta 3D TOF: 0.
57 ± 0.
06, aorta 3D ECG-FSE: 0.
83 ± 0.
06, P < 0.
001; external iliac arteries 3D TOF: 0.
45 ± 0.
06, external iliac arteries 3D ECG-FSE:0.
80 ± 0.
05, P < 0.
001) and similar to those obtained using CE-MRA (aorta: 0.
58 ± 0.
05, external iliac arteries: 0.
57 ± 0.
03).
Moreover, IQS obtained using 3D TOF were significantly higher than those obtained using 3D ECG-FSE (aorta 3D TOF: 3.
95 ± 0.
15, aorta 3D ECG-FSE: 2.
32 ± 0.
60, P < 0.
001; external iliac arteries 3D ECG-FSE: 3.
98 ± 0.
08, external iliac arteries 3D ECG-FSE: 2.
23 ± 0.
56, P < 0.
001) and similar to those obtained using CE-MRA (aorta: 3.
61 ± 0.
41, external iliac arteries: 3.
57 ± 0.
41).
Thus, 3D TOF is more suitable and produces consistent image quality for visualizing the aorta and external iliac arteries in clinically healthy cats and this will be of great help in the diagnosis of FATE.
Related Results
Dynamics of spinor fermions
Dynamics of spinor fermions
Ultracold atomic gases have established themselves as quantum systems, which are clean and offer a high degree of control over crucial parameters. They are well isolated from their...
Atypical Sigmoid Volvulus in an Adolescent: A Case Report and Literature Review
Atypical Sigmoid Volvulus in an Adolescent: A Case Report and Literature Review
Abstract
Introduction
Sigmoid volvulus is an underrecognized diagnosis with potentially fatal outcomes in adolescents; the current study aims to present an adolescent with mild sym...
Spin to charge current interconversion in Rasha interfaces and topological insulators
Spin to charge current interconversion in Rasha interfaces and topological insulators
Conversion entre courant de spin et courant de charge dans des interfaces Rashba et des isolants topologiques
L'interconversion entre courants de spin et de charge ...
e0517 Forearm arteries with ultrasound for percutaneous coronary procedures
e0517 Forearm arteries with ultrasound for percutaneous coronary procedures
Background
The radial artery has become a widely used approach for coronary angiography and intervention in patients, and the ulnar artery is another approach for...
Quantification of defecation frequency in cats with and without chronic kidney disease
Quantification of defecation frequency in cats with and without chronic kidney disease
Objectives
The purpose of this study was to objectively measure defecation frequency in cats with and without chronic kidney disease (CKD). Cats with CKD are at higher ...
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Sleeping and resting respiratory rates in healthy adult cats and cats with subclinical heart disease
Sleeping and resting respiratory rates in healthy adult cats and cats with subclinical heart disease
Sleeping and resting respiratory rates are commonly measured variables in patients with cardiac disease. However, little information is available on these variables in healthy clie...
Flight Reservation System
Flight Reservation System
Flight reservation System is a computerized system used to store and retrieve information and conduct transactions related to air travel. The project is aimed at exposing the relev...