Javascript must be enabled to continue!
Assessing neophyte response to daily disposable silicone hydrogel contact lenses: A randomised clinical trial investigation over one month
View through CrossRef
Abstract
Objective
This randomised clinical trial assessed the impact on symptoms, tear film dynamics and ocular surface integrity of daily disposable silicone‐hydrogel contact lenses (CLs) over a month, paying special attention to lid wiper epitheliopathy (LWE) and its implications for CL discomfort.
Methods
Neophyte CL wearers (
n
= 44, 21.09 ± 5.00 years old) were randomly assigned to either the experimental (
n
= 24) or control group (
n
= 20). Participants assigned to the experimental group were required to wear daily disposable CLs for 1 month for at least 8 h/day and 6 days/week. All participants were healthy subjects (no history of ocular surgery or active ocular disease) with spherical refractive errors between −8.00 and +5.00 D and cylindrical power <0.75 D. At the baseline and 1‐month sessions, the Dry Eye Questionnaire 5 (DEQ‐5) was completed, together with the measurement of tear film osmolarity with the TearLab osmometer, tear meniscus height (TMH) and lipid layer pattern (LLP) using a slit‐lamp with Tearscope Plus attached, fluorescein break‐up time (FBUT), maximum blink interval (MBI), corneal staining with fluorescein under cobalt blue light and LWE with lissamine green under slit lamp and halogen white light.
Results
At the baseline session, LWE showed a negative correlation with DEQ‐5 (
r
= −0.37,
p
= 0.02). Significant differences in FBUT and LWE (
p
= 0.04) and a positive correlation between LWE and DEQ‐5 (
r
= 0.49,
p
= 0.007) were observed at 1 month. Intrasession analysis at 1 month showed significant differences between the experimental and control groups in DEQ‐5, FBUT and LWE (all
p
≤ 0.02). Intersession analysis in the experimental group showed variations in DEQ‐5, FBUT and LWE (all
p
≤ 0.02) but no significant variation in the control group (all
p
≥ 0.11).
Conclusion
The presence of LWE was significantly correlated with higher symptom values in the DEQ‐5. Also, participants in the experimental group presented higher values of LWE after 1 month of CL wear, in comparison with the control group.
Springer Science and Business Media LLC
Title: Assessing neophyte response to daily disposable silicone hydrogel contact lenses: A randomised clinical trial investigation over one month
Description:
Abstract
Objective
This randomised clinical trial assessed the impact on symptoms, tear film dynamics and ocular surface integrity of daily disposable silicone‐hydrogel contact lenses (CLs) over a month, paying special attention to lid wiper epitheliopathy (LWE) and its implications for CL discomfort.
Methods
Neophyte CL wearers (
n
= 44, 21.
09 ± 5.
00 years old) were randomly assigned to either the experimental (
n
= 24) or control group (
n
= 20).
Participants assigned to the experimental group were required to wear daily disposable CLs for 1 month for at least 8 h/day and 6 days/week.
All participants were healthy subjects (no history of ocular surgery or active ocular disease) with spherical refractive errors between −8.
00 and +5.
00 D and cylindrical power <0.
75 D.
At the baseline and 1‐month sessions, the Dry Eye Questionnaire 5 (DEQ‐5) was completed, together with the measurement of tear film osmolarity with the TearLab osmometer, tear meniscus height (TMH) and lipid layer pattern (LLP) using a slit‐lamp with Tearscope Plus attached, fluorescein break‐up time (FBUT), maximum blink interval (MBI), corneal staining with fluorescein under cobalt blue light and LWE with lissamine green under slit lamp and halogen white light.
Results
At the baseline session, LWE showed a negative correlation with DEQ‐5 (
r
= −0.
37,
p
= 0.
02).
Significant differences in FBUT and LWE (
p
= 0.
04) and a positive correlation between LWE and DEQ‐5 (
r
= 0.
49,
p
= 0.
007) were observed at 1 month.
Intrasession analysis at 1 month showed significant differences between the experimental and control groups in DEQ‐5, FBUT and LWE (all
p
≤ 0.
02).
Intersession analysis in the experimental group showed variations in DEQ‐5, FBUT and LWE (all
p
≤ 0.
02) but no significant variation in the control group (all
p
≥ 0.
11).
Conclusion
The presence of LWE was significantly correlated with higher symptom values in the DEQ‐5.
Also, participants in the experimental group presented higher values of LWE after 1 month of CL wear, in comparison with the control group.
Related Results
EFFECTS OF DAILY DISPOSABLE VS EXTENDED WEAR CONTACT LENS ON EYE HEALTH
EFFECTS OF DAILY DISPOSABLE VS EXTENDED WEAR CONTACT LENS ON EYE HEALTH
Background: Vision and eye health are essential for quality of life, impacting education, employment, and daily activities. Vision impairment remains a major public health concern,...
Enhanced mechanical properties of silicone hydrogels coated with metallic nanoparticles by using the laser-assisted process
Enhanced mechanical properties of silicone hydrogels coated with metallic nanoparticles by using the laser-assisted process
Silicone hydrogels coated with metallic nanostructures have attracted extensive attention because of their versatile applications in biomedical devices. However, few studies have b...
Edoxaban and Cancer-Associated Venous Thromboembolism: A Meta-analysis of Clinical Trials
Edoxaban and Cancer-Associated Venous Thromboembolism: A Meta-analysis of Clinical Trials
Abstract
Introduction
Cancer patients face a venous thromboembolism (VTE) risk that is up to 50 times higher compared to individuals without cancer. In 2010, direct oral anticoagul...
Current therapeutic strategies for erectile function recovery after radical prostatectomy – literature review and meta-analysis
Current therapeutic strategies for erectile function recovery after radical prostatectomy – literature review and meta-analysis
Radical prostatectomy is the most commonly performed treatment option for localised prostate cancer. In the last decades the surgical technique has been improved and modified in or...
Bonding of hydrogel to silicone elastomer using a self-healing hydrogel–elastomer two-phase material
Bonding of hydrogel to silicone elastomer using a self-healing hydrogel–elastomer two-phase material
Hypothesis: Bonding of hydrogel with silicone elastomers may allow fusion of conductivity and biodegradability of hydrogel with the mechanical integrity and flexibility of silicone...
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract
Introduction
Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...
Comparative Clinical Performance of Rigid versus Soft Hyper Dk Contact Lenses Used for Continuous Wear
Comparative Clinical Performance of Rigid versus Soft Hyper Dk Contact Lenses Used for Continuous Wear
ABSTRACT
Purpose.
The purpose of this study is to investigate the comparative clinical performance of two hyper Dk contac...
Evaluation of NSAID saturation levels in silicone hydrogel soft contact lenses
Evaluation of NSAID saturation levels in silicone hydrogel soft contact lenses
Background. Only a limited number of studies have reported the clinical use of soft contact lenses pre-soaked in non-steroidal anti-inflammatory drug (NSAID) solutions. Within thes...

