Javascript must be enabled to continue!
Left atrial appendage closure device implantation via transhepatic vascular access: a case report
View through CrossRef
Abstract
Background
In patients with non-valvular atrial fibrillation, an estimated 90% of thrombi are located in the left atrial appendage. The WATCHMAN device is a left atrial appendage closure device that is an alternative therapeutic option to reduce the risk of systemic embolization in patients who are intolerant of long-term oral anticoagulation. It can be deployed in the left atrial appendage using a transseptal approach via the femoral vein. Transhepatic venous access is an alternative route for the delivery of the device in a patient with difficult vascular access.
Case summary
An 81-year-old man with persistent non-valvular atrial fibrillation, heart failure with reduced ejection fraction (HFrEF), and diabetes mellitus was deemed a poor candidate for anticoagulation due to recurrent falls and gastrointestinal bleeding. He was selected for a left atrial appendage closure. The initial procedure was aborted after significant resistance to device advancement was encountered in the right femoral vein. Lower extremity venography demonstrated totally occluded femoral and iliac veins bilaterally. The decision was made to implant the device via a transhepatic approach. The procedure had no complications and the patient was discharged on rivaroxaban and aspirin after 3 days.
Discussion
Transhepatic venous access is a viable option in patients with poor femoral access for implantation of the WATCHMAN device. It can be done safely. Knowledge of this procedural alternative can greatly enhance patient care.
Oxford University Press (OUP)
Title: Left atrial appendage closure device implantation via transhepatic vascular access: a case report
Description:
Abstract
Background
In patients with non-valvular atrial fibrillation, an estimated 90% of thrombi are located in the left atrial appendage.
The WATCHMAN device is a left atrial appendage closure device that is an alternative therapeutic option to reduce the risk of systemic embolization in patients who are intolerant of long-term oral anticoagulation.
It can be deployed in the left atrial appendage using a transseptal approach via the femoral vein.
Transhepatic venous access is an alternative route for the delivery of the device in a patient with difficult vascular access.
Case summary
An 81-year-old man with persistent non-valvular atrial fibrillation, heart failure with reduced ejection fraction (HFrEF), and diabetes mellitus was deemed a poor candidate for anticoagulation due to recurrent falls and gastrointestinal bleeding.
He was selected for a left atrial appendage closure.
The initial procedure was aborted after significant resistance to device advancement was encountered in the right femoral vein.
Lower extremity venography demonstrated totally occluded femoral and iliac veins bilaterally.
The decision was made to implant the device via a transhepatic approach.
The procedure had no complications and the patient was discharged on rivaroxaban and aspirin after 3 days.
Discussion
Transhepatic venous access is a viable option in patients with poor femoral access for implantation of the WATCHMAN device.
It can be done safely.
Knowledge of this procedural alternative can greatly enhance patient care.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Left atrial appendage anatomy and function: short term response to sustained atrial fibrillation
Left atrial appendage anatomy and function: short term response to sustained atrial fibrillation
OBJECTIVE
To determine whether there is significant atrial or atrial appendage enlargement or functional remodelling as a result of one to two months of sustained...
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Hydatid Cyst of The Orbit: A Systematic Review with Meta-Data
Abstarct
Introduction
Orbital hydatid cysts (HCs) constitute less than 1% of all cases of hydatidosis, yet their occurrence is often linked to severe visual complications. This stu...
Rethinking Anticoagulation in Kidney Disease and Kidney Transplantation
Rethinking Anticoagulation in Kidney Disease and Kidney Transplantation
BackgroundA clinical dilemma exists in patients with CKD, ESKD, and after kidney transplantation, as they face concurrent risks of both thromboembolic and hemorrhagic complications...
Left Atrial Appendage Closure for Stroke Prevention
Left Atrial Appendage Closure for Stroke Prevention
Atrial fibrillation is the most common chronic arrhythmia worldwide, and stroke is its most common complication. Approximately 20% of all ischemic strokes attributed to atrial fibr...
Left atrial appendage isolation in catheter ablation of atrial fibrillation: an updated systematic review and meta-analysis
Left atrial appendage isolation in catheter ablation of atrial fibrillation: an updated systematic review and meta-analysis
Abstract
Introduction
Atrial fibrillation is the most encountered arrhythmia in clinical settings, current estimates appr...
Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract
Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...

