Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparative Cytomorphological Analysis on Liquid PRFs Produced with DUO Fixed Angle Centrifuge and Oscillating Centrifuge

View through CrossRef
Background: Liquid PRF is an injectable second-generation platelet concentrate rich in platelets, leukocytes, and fibrinogen obtained by centrifugation of autologous blood. Methods: This study aimed to analyze the cellular and fibrinogen content of various types of liquid PRF (C-PRF liquid, A-PRF liquid, i-PRF, liquid fibrinogen) obtained using a swinging centrifuge with Vacumed FL tubes (code 44909) compared to that obtained with a fixed-angle centrifuge DUO and the original S-PRF Sticky tube. This study found that the average accumulation of thrombocytes was approximately 1.5 times higher than that observed in whole blood. Due to the high concentration of platelets and leukocytes, liquid PRFs contain important growth factors for tissue regeneration. Results: In this definitive study we have highlighted that with the use of the Oscillating centrifuge, the type of Liquid PRF with the highest content of Platelets (133.1% vs 122.9%) is the A-PRF liquid (1300 rpm × 5'), the one with the highest content of Monocytes (142.9% vs 125.0%), with a sufficient content of Lymphocytes (220.0% vs 198.7%), Neutrophil Granulocytes (54.0% vs 58.8%) and Fibrinogen (97.1% vs 104.3%), is the i-PRF (700 rpm × 5 min) obtained with the Vacumed FL tube (code 44909) with statistically insignificant differences compared to those obtained with the S-PRF Sticky test tube, while the content of Fibrinogen present in C-PRF (2500 rpm × 8') is higher (104.0% vs 106.5%) obtained with the with S-PRF Sticky tube with a significant difference (p=0.013). Cellular score was also calculated, finding that the type of liquid PRF with the highest score was i-PRF (700 rpm × 5’) extracted with a Vacumed FL tube in a rocking centrifuge (127.17%). Conclusions: Values were significantly higher than those obtained with the Fixed Angle Centrifuge and with the S-PRF Sticky tube. However, when calculating the cellular score, the highest result, equal to 127.2%, was obtained with i-PRF (700 rpm × 5’) with Vacumed FL tube and Oscillating Centrifuge.
Title: Comparative Cytomorphological Analysis on Liquid PRFs Produced with DUO Fixed Angle Centrifuge and Oscillating Centrifuge
Description:
Background: Liquid PRF is an injectable second-generation platelet concentrate rich in platelets, leukocytes, and fibrinogen obtained by centrifugation of autologous blood.
Methods: This study aimed to analyze the cellular and fibrinogen content of various types of liquid PRF (C-PRF liquid, A-PRF liquid, i-PRF, liquid fibrinogen) obtained using a swinging centrifuge with Vacumed FL tubes (code 44909) compared to that obtained with a fixed-angle centrifuge DUO and the original S-PRF Sticky tube.
This study found that the average accumulation of thrombocytes was approximately 1.
5 times higher than that observed in whole blood.
Due to the high concentration of platelets and leukocytes, liquid PRFs contain important growth factors for tissue regeneration.
Results: In this definitive study we have highlighted that with the use of the Oscillating centrifuge, the type of Liquid PRF with the highest content of Platelets (133.
1% vs 122.
9%) is the A-PRF liquid (1300 rpm × 5'), the one with the highest content of Monocytes (142.
9% vs 125.
0%), with a sufficient content of Lymphocytes (220.
0% vs 198.
7%), Neutrophil Granulocytes (54.
0% vs 58.
8%) and Fibrinogen (97.
1% vs 104.
3%), is the i-PRF (700 rpm × 5 min) obtained with the Vacumed FL tube (code 44909) with statistically insignificant differences compared to those obtained with the S-PRF Sticky test tube, while the content of Fibrinogen present in C-PRF (2500 rpm × 8') is higher (104.
0% vs 106.
5%) obtained with the with S-PRF Sticky tube with a significant difference (p=0.
013).
Cellular score was also calculated, finding that the type of liquid PRF with the highest score was i-PRF (700 rpm × 5’) extracted with a Vacumed FL tube in a rocking centrifuge (127.
17%).
Conclusions: Values were significantly higher than those obtained with the Fixed Angle Centrifuge and with the S-PRF Sticky tube.
However, when calculating the cellular score, the highest result, equal to 127.
2%, was obtained with i-PRF (700 rpm × 5’) with Vacumed FL tube and Oscillating Centrifuge.

Related Results

Cytomorphological characteristics of cervical scrape from diabetes mellitus patients attending tertiary healthcare, Kenya
Cytomorphological characteristics of cervical scrape from diabetes mellitus patients attending tertiary healthcare, Kenya
Abstract Background: Globally, the concurrence of diabetes mellitus and cervical cancer among women is compounded health burden of increasing magnitude. Further, there is ...
Performance-based Institutional Research Funding in Flanders, Belgium
Performance-based Institutional Research Funding in Flanders, Belgium
Research and innovation is one of Flanders’ priorities and over the last three decades its public funding has strongly increased. Universities are key actors in this strategy. They...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Lectin C gene analysis v1
Lectin C gene analysis v1
Mammalian Tissue Total RNA Purification Protocol by GeneJET RNA Purification Kit (Thermo Scientific, USA) Before starting: • Supplement the required amount of Lysis Buffer with β-...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Symmetric and Dual PRFs from Standard Assumptions: A Generic Validation of a Prevailing Assumption
Symmetric and Dual PRFs from Standard Assumptions: A Generic Validation of a Prevailing Assumption
AbstractA two-input function is a dual PRF if it is a PRF when keyed by either of its inputs. Dual PRFs are assumed in the design and analysis of numerous primitives and protocols ...

Back to Top