Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Endurance and Aerodynamic Performance Certification of Aircraft De/Anti-icing Fluids

View through CrossRef
<div class="htmlview paragraph">Three performance certification tests are required for the assessment of aircraft de/anti-icing fluids. The two first, measuring anti-icing endurance, consists of the Water Spray (WSET) and the High Humidity Endurance Tests (HHET). The third, for aerodynamic performance, consists of the Flat Plate Elimination Test (FPET). The three performance tests, used for both deicing and anti-icing fluids, are described in the annexes of AMS1424 and AMS1428. Since February, 2003 they are covered by aerospace standards AS5900 for aerodynamic, and AS5901 for anti-icing endurance performance. The WSET anti-icing endurance test measures the time that a fluid protects a plate, inclined at a 10° angle, subjected to freezing precipitation, from a specified amount of icing. This WSET time then defines the fluid type: it must exceed 3 minutes for a Type I, 30 minutes for a Type II and 80 minutes for a Type IV fluid. The aerodynamic FPET performance test involves measuring the Boundary Layer Displacement Thickness (BLDT) during fluid elimination on a flat plate in a wind tunnel at temperatures from 0 °C down to a possible −45 °C. Two take-off acceleration profiles can be simulated, one for large transport type aircraft, and the other for commuter-type aircraft. A fluid is considered acceptable at a temperature interval if its BLDT is below an acceptance criteria defined by BLDT measurements of a reference fluid tested simultaneously and the fluid elimination is below a given percentage depending on fluid type.</div>
Title: Endurance and Aerodynamic Performance Certification of Aircraft De/Anti-icing Fluids
Description:
<div class="htmlview paragraph">Three performance certification tests are required for the assessment of aircraft de/anti-icing fluids.
The two first, measuring anti-icing endurance, consists of the Water Spray (WSET) and the High Humidity Endurance Tests (HHET).
The third, for aerodynamic performance, consists of the Flat Plate Elimination Test (FPET).
The three performance tests, used for both deicing and anti-icing fluids, are described in the annexes of AMS1424 and AMS1428.
Since February, 2003 they are covered by aerospace standards AS5900 for aerodynamic, and AS5901 for anti-icing endurance performance.
The WSET anti-icing endurance test measures the time that a fluid protects a plate, inclined at a 10° angle, subjected to freezing precipitation, from a specified amount of icing.
This WSET time then defines the fluid type: it must exceed 3 minutes for a Type I, 30 minutes for a Type II and 80 minutes for a Type IV fluid.
The aerodynamic FPET performance test involves measuring the Boundary Layer Displacement Thickness (BLDT) during fluid elimination on a flat plate in a wind tunnel at temperatures from 0 °C down to a possible −45 °C.
Two take-off acceleration profiles can be simulated, one for large transport type aircraft, and the other for commuter-type aircraft.
A fluid is considered acceptable at a temperature interval if its BLDT is below an acceptance criteria defined by BLDT measurements of a reference fluid tested simultaneously and the fluid elimination is below a given percentage depending on fluid type.
</div>.

Related Results

Micro/nano manufacturing aircraft surface with anti-icing and deicing performances: An overview
Micro/nano manufacturing aircraft surface with anti-icing and deicing performances: An overview
Abstract The aircraft surface is prone to icing when flying under windward conditions. It is required to protect the aircraft surface from icing for flight safety...
Nursing Informatics Certification Worldwide: History, Pathway, Roles, and Motivation
Nursing Informatics Certification Worldwide: History, Pathway, Roles, and Motivation
SummaryIntroduction: Official recognition and certification for informatics professionals are essential aspects of workforce development. Objective: To describe the history, pathwa...
Wind Turbine Blade Icing Prediction Using Focal Loss Function and CNN-Attention-GRU Algorithm
Wind Turbine Blade Icing Prediction Using Focal Loss Function and CNN-Attention-GRU Algorithm
Blade icing seriously affects wind turbines’ aerodynamic performance and output power. Timely and accurately predicting blade icing status is crucial to improving the economy and s...
Estimation of rime icing weight on composite insulator and analysis of shed configuration
Estimation of rime icing weight on composite insulator and analysis of shed configuration
The possibility of insulator flashover would be higher with the increase in icing degree. Therefore, the method of monitoring the icing weight of the insulator is of vital importan...
An Extreme‐Environment‐Resistant Self‐Healing Anti‐Icing Coating
An Extreme‐Environment‐Resistant Self‐Healing Anti‐Icing Coating
AbstractAnti‐icing coatings on outdoor infrastructures and transportations inevitably suffer from surface injuries, especially in extreme weather events (e.g., freezing weather or ...
MVD and LWC prediction in icing environment based on genetic algorithm optimized neural network
MVD and LWC prediction in icing environment based on genetic algorithm optimized neural network
Mean volumetric diameter (MVD) and liquid water content (LWC) are two important meteorological parameters that affect aircraft icing, but they are difficult to measure accurately i...
Evaluation and Selection of De-Icing Salt Based on Multi-Factor
Evaluation and Selection of De-Icing Salt Based on Multi-Factor
De-icing salts can greatly ease traffic congestion but introduce corrosion of concrete and damage to plant growth. The decision of which de-icing salt to use becomes a crucial issu...
Experimental Study on Heat Transfer Performance of Solidification Heat Exchanger Enhanced by Ultrasonic
Experimental Study on Heat Transfer Performance of Solidification Heat Exchanger Enhanced by Ultrasonic
Solidification heat exchangers offer an effective solution to the operational limitations of surface water-source heat pumps (SWSHPs) in cold northern regions. However, under near-...

Back to Top