Javascript must be enabled to continue!
Partial Discharge Localization Techniques: A Review of Recent Progress
View through CrossRef
Monitoring the partial discharge (PD) activity of power equipment insulation is crucial to ensure uninterrupted power system operation. PD occurrence is highly correlated to weakened insulation strength. If PD occurrences are left unchecked, unexpected insulation breakdowns may occur. The comprehensive PD diagnostic process includes the detection, localization, and classification of PD. Accurate PD source localization is necessary to locate the weakened insulation segment. As a result, rapid and precise PD localization has become the primary focus of PD diagnosis for power equipment insulation. This paper presents a review of different approaches to PD localization, including conventional, machine learning (ML), and deep learning (DL) as a subset of ML approaches. The review focuses on the ML and DL approaches developed in the past five years, which have shown promising results over conventional approaches. Additionally, PD detection using conventional, unconventional, and a PCB antenna designed based on UHF techniques is presented and discussed. Important benchmarks, such as the sensors used, algorithms employed, algorithms compared, and performances, are summarized in detail. Finally, the suitability of different localization techniques for different power equipment applications is discussed based on their strengths and limitations.
Title: Partial Discharge Localization Techniques: A Review of Recent Progress
Description:
Monitoring the partial discharge (PD) activity of power equipment insulation is crucial to ensure uninterrupted power system operation.
PD occurrence is highly correlated to weakened insulation strength.
If PD occurrences are left unchecked, unexpected insulation breakdowns may occur.
The comprehensive PD diagnostic process includes the detection, localization, and classification of PD.
Accurate PD source localization is necessary to locate the weakened insulation segment.
As a result, rapid and precise PD localization has become the primary focus of PD diagnosis for power equipment insulation.
This paper presents a review of different approaches to PD localization, including conventional, machine learning (ML), and deep learning (DL) as a subset of ML approaches.
The review focuses on the ML and DL approaches developed in the past five years, which have shown promising results over conventional approaches.
Additionally, PD detection using conventional, unconventional, and a PCB antenna designed based on UHF techniques is presented and discussed.
Important benchmarks, such as the sensors used, algorithms employed, algorithms compared, and performances, are summarized in detail.
Finally, the suitability of different localization techniques for different power equipment applications is discussed based on their strengths and limitations.
Related Results
Indoor Localization System Based on RSSI-APIT Algorithm
Indoor Localization System Based on RSSI-APIT Algorithm
An indoor localization system based on the RSSI-APIT algorithm is designed in this study. Integrated RSSI (received signal strength indication) and non-ranging APIT (approximate pe...
Atypical Presentations of Pilonidal Sinus Disease: A Case Series with Literature Review
Atypical Presentations of Pilonidal Sinus Disease: A Case Series with Literature Review
Abstract
Introduction:Â Pilonidal sinus (PNS) typically arises in the sacrococcygeal region but can occasionally present in atypical locations, including the axilla, intermammary re...
Rotating characteristics of glow discharge filament on liquid electrode surface
Rotating characteristics of glow discharge filament on liquid electrode surface
Atmospheric pressure glow discharge above liquid electrode has extensive application potentials in biomedicine, chemical degradation,environmental protection,etc.In this paper,such...
The Effect of Mechanical Vibration on the Characteristics of Pin-plate Electrode Partial Discharge in Oil
The Effect of Mechanical Vibration on the Characteristics of Pin-plate Electrode Partial Discharge in Oil
A ultra-high voltage (UHV) shunt reactor is accompanied by continuous
strong vibration during operation, and its internal partial discharge is
often associated with mechanical vibr...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract
The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical activi...
Exploring Large Language Models Integration in the Histopathologic Diagnosis of Skin Diseases: A Comparative Study
Exploring Large Language Models Integration in the Histopathologic Diagnosis of Skin Diseases: A Comparative Study
Abstract
Introduction
The exact manner in which large language models (LLMs) will be integrated into pathology is not yet fully comprehended. This study examines the accuracy, bene...
Multiple Concurrent Pilonidal Sinuses: Case report and Literature review
Multiple Concurrent Pilonidal Sinuses: Case report and Literature review
Abstract
Introduction: Concurrent pilonidal sinuses (PNSs) at distinct locations are extremely rare. This report highlights an exceptional case of a young female presenting with th...
Readiness for Hospital Discharge and Its Correlation with the Quality of Discharge Teaching among the Parents of Premature Infants in NICU
Readiness for Hospital Discharge and Its Correlation with the Quality of Discharge Teaching among the Parents of Premature Infants in NICU
Objectives. To assess the extent of the readiness for hospital discharge and the correlation with discharge teaching quality among parents of premature infants’ in the NICU. Backgr...

