Javascript must be enabled to continue!
Routine arterial oxygen saturation monitoring is not necessary during transesophageal echocardiography
View through CrossRef
AbstractBackground: Transesophageal echocardiography (TEE) is now an established adjunct to routine echocardiography, its diagnostic impact making it an invaluable first‐line diagnostic procedure in many cardiac conditions. However, there is no unanimity in the way the transesophageal procedure is carried out, especially with regard to the need for antibiotic prophylaxis, sedation, and the monitoring of oxygen saturation.Hypothesis: This study was prospectively undertaken (1) to determine the presence and magnitude of oxygen desaturation and (2) the changes in heart rate and blood pressure following sedation for routine TEE in an unselected and consecutive group of patients to identify those at high risk.Methods: Arterial oxygen saturation, heart rate, and systolic, diastolic, and mean blood pressure were monitored in 106 consecutive patients undergoing routine transesophageal echocardiography. Ninety‐four (89%) patients received intravenous sedation with midazolam.Results: Three min after midazolam administration there was a drop in oxygen saturation from 97 ± 2.5 to 95 ± 2.9 (p<0.001), in systolic blood pressure from 139 ± 19.5 to 124.8 ± 22.2 mmHg (p<0.001), in diastolic blood pressure from 86.6 ± 19.9 to 77.5 ± 17.7 mmHg (p<0.001), and in mean blood pressure from 108.3 ± 18 to 95.6 ± 28.8 mmHg (p<0.001). After introduction of the transesophageal probe and during the examination, there was a further drop in oxygen saturation with a maximum drop at the 15th min of the examination (93.7 ± 3.7 vs. 97 ± 2.5, p<0.001). The maximum blood pressure drop occurred at the 12th min into recovery: systolic blood pressure dropped from 139 ± 19.5 to 118 ± 20.8 mmHg (p<0.001), diastolic blood pressure from 86.6 ± 16.9 to 75.8 ± 17.9 mmHg (p<0.005), and mean blood pressure from 108.3 ± 18 to 92.5 ± 19.4 mmHg (p<0.01). Patients with congestive heart failure had a greater drop in oxygen saturation compared with patients who were not in heart failure (p<0.01). Twelve patients did not receive any sedation; however, they all showed a drop in oxygen saturation from 97.8 ± 2.3 to 94.6 ± 3.4 (p<0.001), with a maximum drop at the 15th min during the transesophageal examination.Conclusion: In patients with no chronic obstructive airway disease who are not in congestive heart failure, routine oxygen saturation monitoring is not deemed necessary during transesophageal examination. The cause of hypoxemia during the procedure is not only related to sedation but also to esophageal intubation.
Title: Routine arterial oxygen saturation monitoring is not necessary during transesophageal echocardiography
Description:
AbstractBackground: Transesophageal echocardiography (TEE) is now an established adjunct to routine echocardiography, its diagnostic impact making it an invaluable first‐line diagnostic procedure in many cardiac conditions.
However, there is no unanimity in the way the transesophageal procedure is carried out, especially with regard to the need for antibiotic prophylaxis, sedation, and the monitoring of oxygen saturation.
Hypothesis: This study was prospectively undertaken (1) to determine the presence and magnitude of oxygen desaturation and (2) the changes in heart rate and blood pressure following sedation for routine TEE in an unselected and consecutive group of patients to identify those at high risk.
Methods: Arterial oxygen saturation, heart rate, and systolic, diastolic, and mean blood pressure were monitored in 106 consecutive patients undergoing routine transesophageal echocardiography.
Ninety‐four (89%) patients received intravenous sedation with midazolam.
Results: Three min after midazolam administration there was a drop in oxygen saturation from 97 ± 2.
5 to 95 ± 2.
9 (p<0.
001), in systolic blood pressure from 139 ± 19.
5 to 124.
8 ± 22.
2 mmHg (p<0.
001), in diastolic blood pressure from 86.
6 ± 19.
9 to 77.
5 ± 17.
7 mmHg (p<0.
001), and in mean blood pressure from 108.
3 ± 18 to 95.
6 ± 28.
8 mmHg (p<0.
001).
After introduction of the transesophageal probe and during the examination, there was a further drop in oxygen saturation with a maximum drop at the 15th min of the examination (93.
7 ± 3.
7 vs.
97 ± 2.
5, p<0.
001).
The maximum blood pressure drop occurred at the 12th min into recovery: systolic blood pressure dropped from 139 ± 19.
5 to 118 ± 20.
8 mmHg (p<0.
001), diastolic blood pressure from 86.
6 ± 16.
9 to 75.
8 ± 17.
9 mmHg (p<0.
005), and mean blood pressure from 108.
3 ± 18 to 92.
5 ± 19.
4 mmHg (p<0.
01).
Patients with congestive heart failure had a greater drop in oxygen saturation compared with patients who were not in heart failure (p<0.
01).
Twelve patients did not receive any sedation; however, they all showed a drop in oxygen saturation from 97.
8 ± 2.
3 to 94.
6 ± 3.
4 (p<0.
001), with a maximum drop at the 15th min during the transesophageal examination.
Conclusion: In patients with no chronic obstructive airway disease who are not in congestive heart failure, routine oxygen saturation monitoring is not deemed necessary during transesophageal examination.
The cause of hypoxemia during the procedure is not only related to sedation but also to esophageal intubation.
Related Results
An Observational Study of Transesophageal Echocardiography in Patients Presenting with Ischemic Stroke
An Observational Study of Transesophageal Echocardiography in Patients Presenting with Ischemic Stroke
Background: Transesophageal echocardiography is a valuable tool for identifying stroke causes, particularly left atrial clots and cardiac abnormalities undetectable by other method...
Retinal Oximetry
Retinal Oximetry
Abstract.Purpose:Malfunction of retinal blood flow or oxygenation is believed to be involved in various diseases. Among them are retinal vessel occlusions, diabetic retinopathy and...
High Concentration Oxygen and Hypercapnia in Respiratory Disease
High Concentration Oxygen and Hypercapnia in Respiratory Disease
<p>Oxygen-induced elevations in arterial carbon dioxide tension have been demonstrated in patients with chronic obstructive pulmonary disease (COPD), asthma, pneumonia, obesi...
0864 Severe Central Sleep Apnea
0864 Severe Central Sleep Apnea
Abstract
Introduction
Central sleep apnea (CSA) is a rare form of sleep disordered breathing with repeated apneic episodes with ...
Benefit of Echocardiography in Patients With Staphylococcus aureus Bacteremia at Low Risk of Endocarditis
Benefit of Echocardiography in Patients With Staphylococcus aureus Bacteremia at Low Risk of Endocarditis
Abstract
Background
The risk of endocarditis among patients with Staphylococcus aureus bacteremia is not uniform, and a number o...
Retinal oxygen saturation in health and disease
Retinal oxygen saturation in health and disease
AbstractPurpose Measurements of retinal vessel oxygen saturation can provide insight into the nature of several eye diseases.Methods Dual wavelength oximeters are used by our group...
Closed-Loop Oxygen Control
Closed-Loop Oxygen Control
<p>Guidelines recommend that oxygen should be titrated to achieve a target oxygen saturation (SpO2 ) range in acutely unwell patients, a concept colloquially known as “swimmi...
Cardiovascular MRI: A valuable tool to detect cardiac source of emboli in cryptogenic ischemic strokes
Cardiovascular MRI: A valuable tool to detect cardiac source of emboli in cryptogenic ischemic strokes
AbstractObjectivesDespite a thorough work‐up including transesophageal echocardiography, 20%–30% of stroke etiology remains cryptogenic. Transesophageal echocardiogram is considere...