Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Research on Impact of Pressurizer Heater Block on SGTR Overfill Analysis

View through CrossRef
Steam generator overfill due to steam generator tube rupture have been analyzed for CAP1400 plant, in which two cases were simulated, including pressurizer heater switching off available and unavailable under low pressurizer water level. The results indicate that it has a certain margin to steam generator (SG) overfill for the ruptured steam generator under steam generator tube rupture (SGTR) accident. Analysis results have also shown that the SG overfill margin will be slightly decreased in case of pressurizer heater swiching off unavailable, however, the impact is not significant.
American Society of Mechanical Engineers
Title: Research on Impact of Pressurizer Heater Block on SGTR Overfill Analysis
Description:
Steam generator overfill due to steam generator tube rupture have been analyzed for CAP1400 plant, in which two cases were simulated, including pressurizer heater switching off available and unavailable under low pressurizer water level.
The results indicate that it has a certain margin to steam generator (SG) overfill for the ruptured steam generator under steam generator tube rupture (SGTR) accident.
Analysis results have also shown that the SG overfill margin will be slightly decreased in case of pressurizer heater swiching off unavailable, however, the impact is not significant.

Related Results

Simulation Analysis on the Pressurizer Degassing Sub-System of Module Small Reactor (ACP100)
Simulation Analysis on the Pressurizer Degassing Sub-System of Module Small Reactor (ACP100)
Abstract A pressurizer degassing sub-system is designed in Module Small Reactor (ACP100), which can be used to vent the non-condensable gas dissolved in Reactor Cool...
Study on Effect of Sloshing Phenomenon on Water Level of Pressurizer
Study on Effect of Sloshing Phenomenon on Water Level of Pressurizer
Abstract As the key equipment to control the pressure stability of the coolant system, the pressurizer plays a role in maintaining the primary system pressure in the...
TEMPERATURE DISTRIBUTION SIMULATION AND OPTIMIZATION DESIGN OF ELECTRIC HEATER FOR IN-SITU OIL SHALE HEATING; pp. 105–120
TEMPERATURE DISTRIBUTION SIMULATION AND OPTIMIZATION DESIGN OF ELECTRIC HEATER FOR IN-SITU OIL SHALE HEATING; pp. 105–120
Electric heating is the main method of exploiting oil shale and electric heater is the key part of the heating element. In this paper, the tem­perature distribution of the electri...
ANALISIS PERBAIKAN KINERJA HEATER PADA SISTEM KILN DRY DI PT. SEJIN LESTARI FURNITURE
ANALISIS PERBAIKAN KINERJA HEATER PADA SISTEM KILN DRY DI PT. SEJIN LESTARI FURNITURE
Penelitian ini menuliskan tentang proses perbaikan sistem heater pada kiln dry dengan fokus pada industri pengeringan kayu di PT. Sejin Lestari Furniture Rangkasbitung. Penelitian ...
Fatigue Strength Evaluation Of Pressurizer Wall Structure In Pressurized Water Reactor
Fatigue Strength Evaluation Of Pressurizer Wall Structure In Pressurized Water Reactor
<p>Fatigue strength evaluations have been performed to the pressurizer component in Pressurized Water Reactor. Fatigue is the main failure mechanism of material during system...
IDENTIFICATION AND ANALYSIS OF HUMAN ACTIONS IN CASE OF SGTR INITIATING EVENT
IDENTIFICATION AND ANALYSIS OF HUMAN ACTIONS IN CASE OF SGTR INITIATING EVENT
Identification and modeling of human actions, from safety point of view is an important part of human reliability analysis of Probabilistic Safety Assessment (PSA). In case of SGTR...
Performance Data of a Distributed Flux Burner in a Heavy Oil Heater Treater
Performance Data of a Distributed Flux Burner in a Heavy Oil Heater Treater
Abstract A common problem with oil-water separation in horizontal heater treaters processing heavy oil is thermal deformation and failure of the heater fire tube. Se...
Post Mortem of a Feedwater Heater With Drains Cooler Failures
Post Mortem of a Feedwater Heater With Drains Cooler Failures
The Paradise Generation Station Unit 3 is a supercritical fossil plant with a 1,078 MW rated capacity. The #3B feedwater heater (FWH) is a two-zone (condensing and subcooling) hori...

Back to Top