Javascript must be enabled to continue!
Gait training with a wearable curara® robot for cerebellar ataxia: a single-arm study
View through CrossRef
Abstract
Background
Ataxic gait is one of the most common and disabling symptoms in people with degenerative cerebellar ataxia. Intensive and well-coordinated inpatient rehabilitation improves ataxic gait. In addition to therapist-assisted gait training, robot-assisted gait training has been used for several neurological disorders; however, only a small number of trials have been conducted for degenerative cerebellar ataxia. We aimed to validate the rehabilitative effects of a wearable “curara®” robot developed in a single-arm study of people with degenerative cerebellar ataxia.
Methods
Twenty participants with spinocerebellar ataxia or multiple system atrophy with predominant cerebellar ataxia were enrolled. The clinical trial duration was 15 days. We used a curara® type 4 wearable robot for gait training. We measured the following items at days 0, 7, and 14: Scale for the Assessment and Rating of Ataxia, 10-m walking time (10 mWT), 6-min walking distance (6 mWD), and timed up and go test. Gait parameters (i.e., stride duration and length, standard deviation of stride duration and length, cadence, ratio of the stance and swing phases, minimum and maximum knee joint angles, and minimum and maximum hip joint angles) were obtained using a RehaGait®. On days 1–6 and 8–13, the participants were instructed to conduct gait training for 30 ± 5 min with curara®. We calculated the improvement rate as the difference of values between days 14 and 0 divided by the value on day 0. Differences in the gait parameters were analyzed using a generalized linear mixed model with Bonferroni’s correction.
Results
Data from 18 participants were analyzed. The mean improvement rate of the 10 mWT and 6 mWD was 19.0% and 29.0%, respectively. All gait parameters, except the standard deviation of stride duration and length, improved on day 14.
Conclusions
Two-week RAGT with curara® has rehabilitative effects on gait function comparable to those of therapist-assisted training. Although the long-term effects after a month of RAGT with curara® are unclear, curara® is an effective tool for gait training of people with degenerative ataxia.
Trial registration jRCT, jRCTs032180164. Registered: 27 February 2019; retrospectively registered. https://jrct.niph.go.jp/en-latest-detail/jRCTs032180164.
Springer Science and Business Media LLC
Title: Gait training with a wearable curara® robot for cerebellar ataxia: a single-arm study
Description:
Abstract
Background
Ataxic gait is one of the most common and disabling symptoms in people with degenerative cerebellar ataxia.
Intensive and well-coordinated inpatient rehabilitation improves ataxic gait.
In addition to therapist-assisted gait training, robot-assisted gait training has been used for several neurological disorders; however, only a small number of trials have been conducted for degenerative cerebellar ataxia.
We aimed to validate the rehabilitative effects of a wearable “curara®” robot developed in a single-arm study of people with degenerative cerebellar ataxia.
Methods
Twenty participants with spinocerebellar ataxia or multiple system atrophy with predominant cerebellar ataxia were enrolled.
The clinical trial duration was 15 days.
We used a curara® type 4 wearable robot for gait training.
We measured the following items at days 0, 7, and 14: Scale for the Assessment and Rating of Ataxia, 10-m walking time (10 mWT), 6-min walking distance (6 mWD), and timed up and go test.
Gait parameters (i.
e.
, stride duration and length, standard deviation of stride duration and length, cadence, ratio of the stance and swing phases, minimum and maximum knee joint angles, and minimum and maximum hip joint angles) were obtained using a RehaGait®.
On days 1–6 and 8–13, the participants were instructed to conduct gait training for 30 ± 5 min with curara®.
We calculated the improvement rate as the difference of values between days 14 and 0 divided by the value on day 0.
Differences in the gait parameters were analyzed using a generalized linear mixed model with Bonferroni’s correction.
Results
Data from 18 participants were analyzed.
The mean improvement rate of the 10 mWT and 6 mWD was 19.
0% and 29.
0%, respectively.
All gait parameters, except the standard deviation of stride duration and length, improved on day 14.
Conclusions
Two-week RAGT with curara® has rehabilitative effects on gait function comparable to those of therapist-assisted training.
Although the long-term effects after a month of RAGT with curara® are unclear, curara® is an effective tool for gait training of people with degenerative ataxia.
Trial registration jRCT, jRCTs032180164.
Registered: 27 February 2019; retrospectively registered.
https://jrct.
niph.
go.
jp/en-latest-detail/jRCTs032180164.
Related Results
Gait training with a wearable curara® robot for cerebellar ataxia: a single-arm study
Gait training with a wearable curara® robot for cerebellar ataxia: a single-arm study
Abstract
Background: Ataxic gait is one of the most common and problematic symptoms in people with degenerative cerebellar ataxia. Intensive and well-coordinated inpatient ...
Gait training with a wearable curara ® robot during stroke rehabilitation: a randomized parallel-group trial
Gait training with a wearable curara ® robot during stroke rehabilitation: a randomized parallel-group trial
Abstract
Background: Recently, robot-assisted gait training (RAGT) has been applied widely to individuals with stroke to regain and improve walking ability. We have develop...
Gait training with a wearable curara ® robot during stroke rehabilitation: a randomized parallel-group trial
Gait training with a wearable curara ® robot during stroke rehabilitation: a randomized parallel-group trial
Abstract
Background: Recently, robot-assisted gait training (RAGT) has been applied widely to individuals with stroke to regain and improve walking ability. We have develop...
Gait training with a wearable powered robot during stroke rehabilitation: a randomized parallel-group trial
Gait training with a wearable powered robot during stroke rehabilitation: a randomized parallel-group trial
Abstract
Background
We have developed a wearable rehabilitation robot, “curara®,” and examined its immediate effect in patients with spinocerebellar...
Research on obstacle climbing gait structure design and gait control of hexapod wall climbing robot based on STM32F103 core controller
Research on obstacle climbing gait structure design and gait control of hexapod wall climbing robot based on STM32F103 core controller
The hexapod wall climbing robots have the advantages of traversing complex wall surfaces. To traverse complex environments autonomously, it must possess the capability to select ga...
Gait Training Techniques in Children
Gait Training Techniques in Children
The development of gait is a fundamental milestone in childhood that signifies the onset of functional independence, social engagement, and cognitive exploration. The book “Gait Tr...
Fetal cerebellar development: 3D morphometric analysis of fetal postmortem MRI among Chinese fetuses
Fetal cerebellar development: 3D morphometric analysis of fetal postmortem MRI among Chinese fetuses
AbstractThe development of the cerebellum starts from early gestational period and extends postnatal. Because of its protracted development, the cerebellum is susceptible to develo...
Biomechanical Gait Variable Estimation Using Wearable Sensors after Unilateral Total Knee Arthroplasty
Biomechanical Gait Variable Estimation Using Wearable Sensors after Unilateral Total Knee Arthroplasty
Total knee arthroplasty is a common surgical treatment for end-stage osteoarthritis of the knee. The majority of existing studies that have explored the relationship between recove...