Javascript must be enabled to continue!
Evaluation of Indoor Thermal Comfort Conditions of Residential Traditional and Modern Buildings in a Warm-Humid Climate
View through CrossRef
Achieving optimal levels of indoor thermal comfort in a warm, humid climate continues to pose a challenge to building occupants in such climatic regions. Buildings are either being retrofitted or designed differently to cater to thermal comfort. As a result, a variety of tactics have been deployed to guarantee optimal thermal comfort for occupants. Some scholars have highlighted the salient contributions of various types of construction materials toward the delivery of different housing types which perform differently under a diverse range of climatic conditions. A plethora of studies suggesting better indoor thermal comfort performance of traditional buildings as compared to contemporary dwellings due to various reasons have been observed. However, limited studies have sought to investigate this suggestion within warm, humid climatic regions. As such, this study engages in an evaluation of indoor thermal comfort qualities of traditional and modern buildings during the dry season with the goal of developing design guidelines for a thermally pleasant environment in a town, Okigwe, which is situated in a warm, humid climatic region in Southeastern Nigeria. Data were collected utilizing a field measurement technique. Throughout the survey period, variables of the indoor environment such as relative humidity and air temperature were recorded concurrently in nine selected buildings, two traditional and seven modern buildings. The fluctuations and differences in relative humidity and air temperature between the two building types were investigated using Z-test statistical techniques. The study’s results revealed that the contemporary structures’ indoor air temperature (29.4 °C) was 0.6 °C higher than traditional buildings’ indoor air temperature (28.8 °C). Therefore, the study recommends that architects and planners should make concerted efforts to integrate methods of passive design into the provision of a comfortable indoor thermal environment rather than relying solely on active design strategies, which whilst lacking in traditional buildings, nonetheless did not prevent such buildings from recording lower air temperature readings compared to modern buildings.
Title: Evaluation of Indoor Thermal Comfort Conditions of Residential Traditional and Modern Buildings in a Warm-Humid Climate
Description:
Achieving optimal levels of indoor thermal comfort in a warm, humid climate continues to pose a challenge to building occupants in such climatic regions.
Buildings are either being retrofitted or designed differently to cater to thermal comfort.
As a result, a variety of tactics have been deployed to guarantee optimal thermal comfort for occupants.
Some scholars have highlighted the salient contributions of various types of construction materials toward the delivery of different housing types which perform differently under a diverse range of climatic conditions.
A plethora of studies suggesting better indoor thermal comfort performance of traditional buildings as compared to contemporary dwellings due to various reasons have been observed.
However, limited studies have sought to investigate this suggestion within warm, humid climatic regions.
As such, this study engages in an evaluation of indoor thermal comfort qualities of traditional and modern buildings during the dry season with the goal of developing design guidelines for a thermally pleasant environment in a town, Okigwe, which is situated in a warm, humid climatic region in Southeastern Nigeria.
Data were collected utilizing a field measurement technique.
Throughout the survey period, variables of the indoor environment such as relative humidity and air temperature were recorded concurrently in nine selected buildings, two traditional and seven modern buildings.
The fluctuations and differences in relative humidity and air temperature between the two building types were investigated using Z-test statistical techniques.
The study’s results revealed that the contemporary structures’ indoor air temperature (29.
4 °C) was 0.
6 °C higher than traditional buildings’ indoor air temperature (28.
8 °C).
Therefore, the study recommends that architects and planners should make concerted efforts to integrate methods of passive design into the provision of a comfortable indoor thermal environment rather than relying solely on active design strategies, which whilst lacking in traditional buildings, nonetheless did not prevent such buildings from recording lower air temperature readings compared to modern buildings.
Related Results
De gevel – een intermediair element tussen buiten en binnen
De gevel – een intermediair element tussen buiten en binnen
This study is based on the fact that all people have a basic need for protection from other people (and animals) as well as from the elements (the exterior climate). People need a ...
“The Earth Is Dying, Bro”
“The Earth Is Dying, Bro”
Climate Change and Children
Australian children are uniquely situated in a vast landscape that varies drastically across locations. Spanning multiple climatic zones—from cool tempe...
Architecture and adaptation
Architecture and adaptation
«The architectural work transcends the architect, goes beyond the moment in which its construction takes place, and therefore can be contemplated under the changing lights of histo...
Microclimatic comfort measurements evaluation of building physics: The effect of building form and building settled area, on pedestrian level comfort around buildings
Microclimatic comfort measurements evaluation of building physics: The effect of building form and building settled area, on pedestrian level comfort around buildings
Wind discomfort and the dangers that the wind may lead can be harmful in terms of comfort conditions of both indoor and outdoor environment of the building/buildings to be construc...
Dwelling on Courtyards
Dwelling on Courtyards
The urban heat island (UHI) phenomenon and the dependency of buildings on
fossil fuels were the two main issues that formed this dissertation. UHI results in higher air temperature...
Ethics of climate change : a normative account
Ethics of climate change : a normative account
Consider, for instance, you and your family have lived around a place where you enjoyed the flora and fauna of the land as well as the natural environment. Fishing and farming were...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Climate and Culture
Climate and Culture
Climate is, presently, a heatedly discussed topic. Concerns about the environmental, economic, political and social consequences of climate change are of central interest in academ...

