Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

In situ determination of water-saturated solidus by electrical discontinuity

View through CrossRef
<p><span>Water plays an important role in lowering melting temperature of rocks. The water-saturated solidus of rock is critical for understanding the magma generation and the dynamics of the Earth. There have been a lot of water-saturated solidi of rocks constrained by traditional quench method in literature. However, since both of the hydrous silicate melt and aqueous fluid can be quenched to glasses at high pressure, it is difficult to discriminate whether the quenched glasses were from melt or not. As a result, the water-saturated solidi of rocks from different studies may show significant discrepancy. One way to solve this problem is to detect the characteristics change of the rock system in situ, and electrical conductivity measurement is one of the good options. It is known that hydrous melt has much higher electrical conductivity than solid rock, and temperature is much more effective in enhancing melt electrical conductivity than that for aqueous fluid. Once the partial melting is triggered, the electrical conductivity of the water-saturated rock system may have remarkable increase if the hydrous melt is interconnected in the system. Accordingly, the abrupt change of electrical conductivity may mark the solidus temperature. In this study, we performed electrical conductivity measurement for the determination of water-saturated solidus of albite. We adopted albite as the starting material because its water-saturated solidus is well known, which can help to verify the accuracy our method, and its quenched products are not so controversial. The electrical conductivity measurements were carried out at four different pressures ranging from 0.35 GPa to 1.7 GPa in a 3/4″ piston cylinder apparatus with impedance spectroscopy. The obvious change of electrical conductivity was observed at solidus temperature within error, with increase of 1.8-0.18 log unit at 0.35-1.7 GPa. The results showed a stronger increase of conductivity at lower pressures, and fitted well with the water-saturated solidus of albite in literature. One defect of this method is the loss of water during experiment. The final water content in the system is about 1-2 wt%, comparing to the initial 10-15 wt% H<sub>2</sub>O. Nevertheless, the whole system is still water saturated, since water solubility in albite is fairly low. Therefore, if such a method can be improved to keep more water, it may be applied to other rocks to better constrain the water-saturated solidi in the future.</span></p><p> </p>
Copernicus GmbH
Title: In situ determination of water-saturated solidus by electrical discontinuity
Description:
<p><span>Water plays an important role in lowering melting temperature of rocks.
The water-saturated solidus of rock is critical for understanding the magma generation and the dynamics of the Earth.
There have been a lot of water-saturated solidi of rocks constrained by traditional quench method in literature.
However, since both of the hydrous silicate melt and aqueous fluid can be quenched to glasses at high pressure, it is difficult to discriminate whether the quenched glasses were from melt or not.
As a result, the water-saturated solidi of rocks from different studies may show significant discrepancy.
One way to solve this problem is to detect the characteristics change of the rock system in situ, and electrical conductivity measurement is one of the good options.
It is known that hydrous melt has much higher electrical conductivity than solid rock, and temperature is much more effective in enhancing melt electrical conductivity than that for aqueous fluid.
Once the partial melting is triggered, the electrical conductivity of the water-saturated rock system may have remarkable increase if the hydrous melt is interconnected in the system.
Accordingly, the abrupt change of electrical conductivity may mark the solidus temperature.
In this study, we performed electrical conductivity measurement for the determination of water-saturated solidus of albite.
We adopted albite as the starting material because its water-saturated solidus is well known, which can help to verify the accuracy our method, and its quenched products are not so controversial.
The electrical conductivity measurements were carried out at four different pressures ranging from 0.
35 GPa to 1.
7 GPa in a 3/4″ piston cylinder apparatus with impedance spectroscopy.
The obvious change of electrical conductivity was observed at solidus temperature within error, with increase of 1.
8-0.
18 log unit at 0.
35-1.
7 GPa.
The results showed a stronger increase of conductivity at lower pressures, and fitted well with the water-saturated solidus of albite in literature.
One defect of this method is the loss of water during experiment.
The final water content in the system is about 1-2 wt%, comparing to the initial 10-15 wt% H<sub>2</sub>O.
Nevertheless, the whole system is still water saturated, since water solubility in albite is fairly low.
Therefore, if such a method can be improved to keep more water, it may be applied to other rocks to better constrain the water-saturated solidi in the future.
</span></p><p> </p>.

Related Results

A New Method for Calculating Saturated Fat Content and Determining Appropriate Saturated Fat Levels in Foods
A New Method for Calculating Saturated Fat Content and Determining Appropriate Saturated Fat Levels in Foods
Calculating the saturated fat content per 100 g or 100 mL or the reference amount customarily consumed (RACC) of food shows the saturated fat content of some foods inappropriately....
Water-saturated solidus and second critical endpoint of peridotite determined from liquid texture and chemistry
Water-saturated solidus and second critical endpoint of peridotite determined from liquid texture and chemistry
The melting of peridotite plays a key role in the chemical differentiation of planetary bodies. Water-saturated (‘wet’) solidus of mantle peridotite defines initial melting tempera...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Water Trash Collector
Water Trash Collector
In today day to day life, approximately 71% of the Earth's surface is covered by Without affecting significant role that technology plays in our modern world, environmental and wat...
Integrated hydrological modelling for sustainable water allocation planning : Mkomazi Basin, South Africa case study
Integrated hydrological modelling for sustainable water allocation planning : Mkomazi Basin, South Africa case study
Allocation of freshwater resources between societal needs and natural ecological systems is of great concern for water managers. This development has challenged decision-makers reg...
Diagnostic value of ultrasonography in acute lateral and syndesmotic ligamentous ankle injuries
Diagnostic value of ultrasonography in acute lateral and syndesmotic ligamentous ankle injuries
Abstract Objectives To determine the diagnostic value of ultrasonography for complete discontinuity of the anterior talofibular ligament (ATFL), the...

Back to Top